Abstract
Hypersensitivity to metals and tissue reaction around a failed implant were investigated in 40 patients undergoing revision hip arthroplasty. Metal sensitivity was tested using a standard cutaneous patch test. Nine patients were positive for chromium, nickel, cobalt, metal rust or endoprosthesis scrapings, or combinations of these allergens. Patients with positive or negative patch test did not differ in terms of their age, sex, primary diagnosis, number of endoprosthesis revisions, length of implant function, presence of other metal parts around the implant, circulating immunocomplexes, and histological appearance of the tissue around the implant. We conclude that stainless steel endoprostheses may be safely used for repeated revision hip arthroplasty, and that hypersensitivity to metals probably does not play a significant role in the loosening of the endoprosthesis.
Similar content being viewed by others
Author information
Authors and Affiliations
Additional information
Received: 13 February 1997
Rights and permissions
About this article
Cite this article
Milavec-Puretić, V., Orlić, D. & Marušić, A. Sensitivity to metals in 40 patients with failed hip endoprosthesis. Arch Orth Traum Surg 117, 383–386 (1998). https://doi.org/10.1007/s004020050272