Scope and limitations of ultrasonography in the documentation of fractures – an experimental study

  • Clinical and experimental forum
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Abstract

Sonographic studies were performed on cadaveric bones placed in a water bath, using 7.5-MHz linear-array transducers and 3.5-MHz sector transducers. Depending on its size, the defect was revealed as an interruption of the cortical reflection of echo or a dorsal band of echoes confined to the region of the fracture. It was interesting to note that fractures and bony defects are not visualized when the transducer is placed parallel to the fracture line or the zone of bony impaction. A further remarkable aspect was the numerous artefacts adjacent to each other at several fracture margins. It may be concluded that in an experimental setting and under standardized conditions, high-resolution transducers permit the examiner to detect cortical discontinuities of 1 mm or more.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 20 January 1997

Rights and permissions

Reprints and permissions

About this article

Cite this article

Grechenig, W., Clement, H., Fellinger, M. et al. Scope and limitations of ultrasonography in the documentation of fractures – an experimental study. Arch Orth Traum Surg 117, 368–371 (1998). https://doi.org/10.1007/s004020050268

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004020050268

Keywords

Navigation