Abstract
Background
Total knee arthroplasty (TKA) is a common procedure that has a risk of significant blood loss and blood transfusion, and carries a substantial risk for immunologic reactions and disease transmission. Drain clamping is a popular method that is applied to reduce blood loss after TKA. However, the clamping protocol remains controversial. Therefore, we established a new protocol, 3-h interval clamping, and compared the bleeding control efficacy of this protocol following TKA with the non-clamping technique.
Methods
Between March and July 2008, we enrolled 100 patients (100 knees) who underwent uncomplicated TKA using a minimally invasive surgical technique. The patients were randomly assigned into two groups based on the draining protocol: non-clamping (group A) and 3-h interval clamping (group B). For group A, a vacuum drain was connected to a container and was run continuously during the first postoperative day, whereas the vacuum was stopped twice (for ~3 h each time) for group B. Demographic characteristics and clinical data were collected, including the levels of hemoglobin and hematocrit, the total blood loss volume, the number of patients who required a blood transfusion, and any complications that developed. The perioperative data were compared between the two groups.
Results
The drainage blood volume in the interval-clamping group (group B) was significantly lower than that in the non-clamping group (group A) during the first 48 h following the procedure (p < 0.001 and p = 0.005 for first and second postoperative days, respectively). The mean fall in hemoglobin levels at 12 h in the interval-clamping group (2.8 ± 0.9 g/dL) was also lower than in the non-clamping group (3.2 ± 0.8 g/dL). In the 3-h interval clamping protocol, the number of patients requiring a transfusion was 2.2 times less than the number in the non-clamping protocol, but was not significantly different (odds ratio = 2.20, p = 0.24), and the significant predictor of blood transfusion was the preoperative hemoglobin level (odds ratio = 7.73, p < 0.001). No wound infection or clinical venous thromboembolisms were detected in our study.
Conclusion
The 3-h interval clamping is a newly developed protocol for reducing blood loss after TKA. The protocol lessens the decrease in postoperative hemoglobin levels. This protocol can be applied easily without increasing clinical thromboembolic events and wound complications.
Similar content being viewed by others
References
Schreiber GB, Busch MP, Kleinman SH, Korelitz JJ (1996) The risk of transfusion transmitted viral infections: the retrovirus epidemiology donor study. N Engl J Med 334:1685–1690
Gascon P, Zoumbos NC, Young NS (1984) Immunologic abnormalities in patients receiving multiple blood transfusions. Ann Intern Med 100:173–177
Dalen T, Brostrom LA, Engstrom KG (1997) Autotransfusion after total knee arthroplasty. Effects on blood cell, plasma chemistry and whole blood rheology. J Arthroplasty 12:517–525
Newman JH, Bowers M, Murphy J (1997) The clinical advantages of autologous transfusion. A randomised, controlled study after knee replacement. J Bone Joint Surg Br 79:630–632
Gannon DM, Lombardi AV Jr, Mallory TH, Vaughn BK, Finney CR, Niemcryk S (1991) An evaluation of the efficacy of postoperative blood salvage after total joint arthroplasty: a prospective randomized trial. J Arthroplasty 6:109–114
Sinha A, Sinha M, Burgert S (2001) Reinfusion of drained blood as an alternative to homologous blood transfusion after total knee replacement. Int Orthop 25:257–259
Juelsgaard P, Larsen UT, Sorensen JV, Madsen F, Soballe K (2001) Hypotensive epidural anesthesia in total knee replacement without tourniquet: reduced blood loss and transfusion. Reg Anesth Pain Med 26:105–110
Orpen NM, Little C, Walker G, Crawfurd EJ (2006) Tranexamic acid reduces early post-operative blood loss after total knee arthroplasty: a prospective randomized controlled trial of 29 patients. Knee 13:106–110
Charoencholvanich K, Siriwattanasakul P (2011) Tranexamic acid reduces blood loss and blood transfusion after TKA: a prospective randomized controlled trial. Clin Orthop Relat Res 469(10):2874–2880
Yamada K, Imaizumi T, Uemura M, Takada N, Kim Y (2001) Comparison between 1-hour and 24-hour drain clamping using diluted epinephrine solution after total knee arthroplasty. J Arthroplasty 16:458–462
Raut VV, Stone MH, Wroblewski BM (1993) Reduction of postoperative blood loss after press-fit condylar knee arthroplasty with use of a femoral intramedullary plug. J Bone Joint Surg Am 75:1356–1357
Gibbons CE, Solan MC, Ricketts DM, Patterson M (2001) Cryotherapy compared with Robert Jones bandage after total knee replacement: a prospective randomized trial. Int Orthop 25:250–252
Brodell JD, Axon DL, Evarts CM (1986) The Robert Jones bandage. J Bone Joint Surg Br 68B:776–779
Tsumara N, Yoshiya S, Chin T, Shiba R, Kohso K, Doita M (2006) A prospective comparison of clamping the drain or post-operative salvage of blood in reducing blood loss after total knee arthroplasty. J Bone Joint Surg Br 88:49
Stucinskas J, Tarasevicius S, Cebatorius A, Robertsson O, Smailys A, Wingstrand H (2008) Conventional drainage versus four hour clamping drainage after total knee arthroplasty in severe osteoarthritis: a prospective, randomised trial. Int Orthop 33(5):1275–1278
Crevoisier XM, Reber P, Noesberger B (1998) Is suction drainage necessary after total joint arthroplasty? A prospective study. Arch Orthop Trauma Surg 117:121
Esler CN, Blakeway C, Fiddian NJ (2003) The use of a closed-suction drain in total knee arthroplasty. A prospective, randomized study. J Bone Joint Surg Br 85:215
Drinkwater CJ, Neil MJ (1995) Optimal timing of wound drain removal following total joint arthroplasty. J Arthroplasty 10:185
Holt BT, Parks NL, Engh GA, Lawrence JM (1997) Comparison of closed-suction drainage and no drainage after primary total knee arthroplasty. Orthopedics 20:1121
Kim YH, Cho SH, Kim RS (1998) Drainage versus nondrainage in simultaneous bilateral total knee arthroplasties. Clin Orthop Relat Res 347:188–193
Willeman D, Paul J, White SH, Crook DW (1991) Closed suction drainage following knee arthroplasty: effectiveness and risks. Clin Orthop 264:232–234
Canty SJ, Shepard GJ, Ryan WG, Banks AJ (2003) Do we practice evidence based medicine with regard to drain usage in knee arthroplasty? Results of a questionnaire of BASK members. Knee 10:385
Raleigh E, Hing CB, Hanusiewicz AS, Fletcher SA, Price R (2007) Drain clamping in knee arthroplasty, a randomized controlled trial. ANZ J Surg 77:333
Fan CH, Hung HH, Chiu KH (2006) Rate of drainage following total knee replacement. J Orthop Surg (Hong Kong) 10(1):10–13
Senthil KG, Von Arx OA, Pozo JL (2005) Rate of blood loss over 48 hours following total knee replacement. Knee 12:307
Kiely N, Hockings M, Gambhir A (2001) Does temporary clamping of drains following knee arthroplasty reduce blood loss? A randomised controlled trial. Knee 8:325
Shen PC, Jou IM, Lin YT, Lai KA, Yang CY, Chern TC (2005) Comparison between 4-hour clamping drainage and nonclamping drainage after total knee arthroplasty. J Arthroplasty 20:909
Eum DS, Lee HK, Hwang SY, Park JU (2006) Blood loss after navigation-assisted minimally invasive total knee arthroplasty. Orthopedics 29:S152
Sakihara H, Fukubayashi T, Okuwaki T (1988) A method to control postoperative bleeding after total knee replacement. Seikei-saigaigeka 31:543–545 (in Japanese)
Ryu J, Sakamoto A, Honda T, Saito S (1997) The postoperative drain-clamping method for hemostasis in total knee arthroplasty: reducing postoperative bleeding in total knee arthroplasty. Bull Hosp Jt Dis 56:251–254
Aglietti P, Baldini A, Vena LM, Abbate R, Fedi S, Falciani M (2000) Effect of tourniquet use on activation of coagulation in total knee replacement. Clin Orthop Relat Res 371:169–177
Tai TW, Yang CY, Jou IM, Lai KA, Chen CH (2010) Temporary drainage clamping after total knee arthroplasty A meta-analysis of randomized controlled trials. J Arthroplasty 25:8. doi:10.1016/j.arth.2009.08.013
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Pornrattanamaneewong, C., Narkbunnam, R., Siriwattanasakul, P. et al. Three-hour interval drain clamping reduces postoperative bleeding in total knee arthroplasty: a prospective randomized controlled trial. Arch Orthop Trauma Surg 132, 1059–1063 (2012). https://doi.org/10.1007/s00402-012-1501-z
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00402-012-1501-z