Abstract

Introduction

The results and complications using a palmar plate system with the possibility of multidirectional fixed-angle screw fixation (Aptus® Radius 2.5 mm by Medartis®) for the treatment of unstable distal radius fractures were evaluated in a single cohort study including 62 patients.

Patients

Patients with extra- and intraarticular fractures were evaluated separately. The mean follow-up was 14.7 months. Active wrist motion averaged 60.1° extension, 52.0° flexion, 86.3° pronation, and 84.6° supination. Grip strength averaged 89% of the contralateral wrist.

Results

There was no loss of the initial reduction with bony union in all cases. The mean DASH-score was 12.6 points. Postoperative complications included two extensor pollicis longus tendon ruptures, two median nerve compression syndromes, one complex regional pain syndrome, and one postoperative haematoma. In our series the results of the intraarticular fracture group were similar to the extraarticular fracture group. The complication rate, however, was substantially higher in the intraarticular fracture group.

Conclusion

We conclude that palmar plating with multidirectional fixed-angle screw insertion is an effective and useful treatment option, especially for complex intraarticular distal radius fractures.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Altissimi M, Antenucci R, Fiacca C, Mancini GB (1986) Long-term results of conservative treatment of fractures of the distal radius. Clin Orthop Relat Res 206:202–210

    PubMed  Google Scholar 

  2. Bradway JK, Amadio PC, Cooney WP (1989) Open reduction and internal fixation of displaced, comminuted intra-articular fractures of the distal end of the radius. J Bone Joint Surg Am 71:839–847

    CAS  PubMed  Google Scholar 

  3. Fernandez DR (2000) Should anatomic reduction be pursued in distal radial fractures? J Hand Surg Br 25:523–527

    Article  CAS  PubMed  Google Scholar 

  4. Field J, Warwick D, Bannister GC, Gibson AG (1992) Long-term prognosis of displaced Colles’ fracture: a 10-year prospective review. Injury 23:529–532

    Article  CAS  PubMed  Google Scholar 

  5. Jupiter JB, Fernandez DL, Toh CL, Fellman T, Ring D (1996) Operative treatment of volar intra-articular fractures of the distal end of the radius. J Bone Joint Surg Am 78:1817–1828

    CAS  PubMed  Google Scholar 

  6. Jupiter JB, Ring D, Weitzel PP (2002) Surgical treatment of redisplaced fractures of the distal radius in patients older than 60 years. J Hand Surg Am 27:714–723

    Article  PubMed  Google Scholar 

  7. Trumble TE, Schmitt SR, Vedder NB (1994) Factors affecting functional outcome of displaced intra-articular distal radius fractures. J Hand Surg Am 19:325–340

    Article  CAS  PubMed  Google Scholar 

  8. Drobetz H, Kutscha-Lissberg E (2003) Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 27:1–6

    CAS  PubMed  Google Scholar 

  9. Kamano M, Honda Y, Kazuki K, Yasuda M (2002) Palmar plating for dorsally displaced fractures of the distal radius. Clin Orthop Relat Res 397:403–408

    Article  PubMed  Google Scholar 

  10. Mehling I, Meier M, Schloer U, Krimmer H (2007) Multidirectional palmar fixed-angle plate fixation for unstable distal radius fracture. Handchir Mikrochir Plast Chir 39:29–33

    Article  CAS  PubMed  Google Scholar 

  11. Orbay JL, Fernandez DL (2002) Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am 27:205–215

    Article  PubMed  Google Scholar 

  12. Orbay JL, Fernandez DL (2004) Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg Am 29:96–102

    Article  PubMed  Google Scholar 

  13. Osada D, Kamei S, Masuzaki K, Takai M, Kameda M, Tamai K (2008) Prospective study of distal radius fractures treated with a volar locking plate system. J Hand Surg Am 33:691–700

    Article  PubMed  Google Scholar 

  14. Ruch DS, Papadonikolakis A (2006) Volar versus dorsal plating in the management of intra-articular distal radius fractures. J Hand Surg Am 31:9–16

    Article  PubMed  Google Scholar 

  15. Lafontaine M, Hardy D, Delince P (1989) Stability assessment of distal radius fractures. Injury 20:208–210

    Article  CAS  PubMed  Google Scholar 

  16. Mueller MR, Nazarian S, Koch P, Schatzker J (1990) The comprehensive classification of fractures of long bones. Springer, Berlin

    Google Scholar 

  17. Orbay JL, Badia A, Indriago IR et al (2001) The extended flexor carpi radialis approach: a new perspective for the distal radius fracture. Tech Hand Up Extrem Surg 5:204–211

    Article  CAS  PubMed  Google Scholar 

  18. Orbay JL, Touhami A (2006) Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res 445:58–67

    PubMed  Google Scholar 

  19. Mathiowetz V, Weber K, Volland G, Kashman N (1984) Reliability and validity of grip and pinch strength evaluations. J Hand Surg Am 9:222–226

    CAS  PubMed  Google Scholar 

  20. Hudak PL, Amadio PC, Bombardier C (1996) Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand) [corrected]. The Upper Extremity Collaborative Group (UECG). Am J Ind Med 29:602–608

    Article  CAS  PubMed  Google Scholar 

  21. Chung KC, Watt AJ, Kotsis SV, Margaliot Z, Haase SC, Kim HM (2006) Treatment of unstable distal radial fractures with the volar locking plating system. J Bone Joint Surg Am 88:2687–2694

    Article  PubMed  Google Scholar 

  22. Figl M, Weninger P, Liska M, Hofbauer M, Leixnering M (2009) Volar fixed-angle osteosynthesis of unstable distal radius fractures: 12 months results. Arch Orthop Trauma Surg 129:661–669

    Article  PubMed  Google Scholar 

  23. Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking plate. J Orthop Trauma 21:316–322

    Article  PubMed  Google Scholar 

  24. Benson EC, DeCarvalho A, Mikola EA, Veitch JM, Moneim MS (2006) Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop Relat Res 451:218–222

    Article  PubMed  Google Scholar 

  25. Rampoldi M, Marsico S (2007) Complications of volar plating of distal radius fractures. Acta Orthop Belg 73:714–719

    PubMed  Google Scholar 

  26. Cross AW, Schmidt CC (2008) Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg Am 33:164–167

    Article  PubMed  Google Scholar 

  27. Hohendorff B, Kurzen P, Boss A (2006) Flexor tendon rupture after palmar osteosynthesis using a multidirectional fixed-angle plate. Unfallchirurg 109:995–997

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Juerg Sonderegger.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sonderegger, J., Schindele, S., Rau, M. et al. Palmar multidirectional fixed-angle plate fixation in distal radius fractures: do intraarticular fractures have a worse outcome than extraarticular fractures?. Arch Orthop Trauma Surg 130, 1263–1268 (2010). https://doi.org/10.1007/s00402-010-1045-z

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00402-010-1045-z

Keywords

Navigation