Foreign body reaction due to polyethylene’s wear after implantation of an interspinal segment

  • Orthopaedic Surgery
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Abstract

Different interspinous implants are used as minimal invasive intervention in the management of degenerative disorders of the lumbar spine. We present a case with foreign body reaction due to polyethylene’s wear after a device for intervertebral assisted motion (DIAM) implantation. We conclude that the polyethylene interspinous devices can cause biological response, therefore; the surgeons and the companies should carefully watch their patients following application of such devices.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Christie SD, Song JK, Fessler RG (2005) Dynamic interspinous process technology. Spine 30(Suppl 16): S73–S78

    Article  PubMed  Google Scholar 

  2. Korovessis P, Papazisis Z, Koureas G, Lambiris E (2004) Rigid, semirigid versus dynamic instrumentation for degenerative lumbar spinal stenosis: a correlative radiological and clinical analysis of short-term results. Spine 29(7): 735–742

    Article  PubMed  Google Scholar 

  3. Lindsey DP, Swanson KE, Fuchs P, Hsu KY, Zucherman JF, Yerby SA (2003) The effects of an interspinous implant on the kinematics of the instrumented and adjacent levels in the lumbar spine. Spine 28(19): 2192–2197

    Article  PubMed  Google Scholar 

  4. Mariottini A, Pieri S, Giachi S, Carangelo B, Zalaffi A, Muzii FV, Palma L (2005) Preliminary results of a soft novel lumbar intervertebral prothesis (DIAM) in the degenerative spinal pathology. Acta Neurochir 92:129–131

    Article  CAS  Google Scholar 

  5. Nockels RP (2005) Dynamic stabilization in the surgical management of painful lumbar spinal disorders. Spine 30(Suppl 16): S68–S72

    Article  PubMed  Google Scholar 

  6. Schwarzenbach O, Berlemann U, Stoll TM, Dubois G (2005) Posterior dynamic stabilization systems: DYNESYS. Orthop Clin North Am 36(3):363–372

    Article  PubMed  Google Scholar 

  7. Senegas J (2002) Mechanical supplementation by non-rigid fixation in degenerative intervertebral lumbar segments: the Wallis system. Eur Spine 11(Suppl 2): S164–S169

    Google Scholar 

  8. Willert HG (1977) Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res 11(2):157–164

    Article  PubMed  CAS  Google Scholar 

  9. Wiseman CM, Lindsey DP, Fredrick AD, Yerby SA (2005) The effect of an interspinous process implant on facet loading during extension. Spine 30(8):903–907

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Joerg Jerosch.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jerosch, J., Moursi, M.G. Foreign body reaction due to polyethylene’s wear after implantation of an interspinal segment. Arch Orthop Trauma Surg 128, 1–4 (2008). https://doi.org/10.1007/s00402-007-0354-3

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00402-007-0354-3

Keywords

Navigation