Serious metallosis of a metal head due to fragmented ceramic screws in a cemented THA

  • Case Report
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Abstract

We reported a rare revision case necessitated by massive metallosis of a metal head due to a fragmented ceramic screw which had been extraarticularily used in the primary THA here and reviewed previous literature about metallosis of metal heads associated with ceramic materials. The ceramic screw had been used for the fixation of a bone graft and reattachment of the greater trochanter in the primary THA. Scanning electron microscope analysis revealed large alumina ceramic particles embedded on the bearing surface of the polyethylene. It has previously been pointed out that metallosis of an inner head occurred in bipolar case due to a fracture of the ceramic screws in contact with a proximally migrated outer head. However, this case showed that if a ceramic screw fragmented even though it was used outside of the hip joint, the fragments could migrate into bearing surface and cause serious metallosis of the metal head. Thus, we recommend that surgeons should pay special attention to the radiographic signs of ceramic failure or metallosis such as a change of the metal head contour, if an aseptic loosening or severe osteolysis is observed in a THA in which ceramic materials were used near the hip joint. And, when a surgical revision is planned, the surgeon should be prepared to exchange with a new ceramic head.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8.
Fig. 9

Similar content being viewed by others

References

  1. Allain J, Roudot-Thoraval F, Delecrin J, Anract P, Migaud H, Goutallier D (2003) Revision total hip arthroplasty performed after fracture of a ceramic femoral head. A multicenter survivorship study. J Bone Joint Surg Am 85:825

    PubMed  Google Scholar 

  2. Besong AA, Hailey JL, Ingham E, Stone M, Wroblewski BM, Fisher J (1997) A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of UHMWPE. Biomed Mater Eng 7:59

    PubMed  CAS  Google Scholar 

  3. Bohler M, Mochida Y, Bauer TW, Plenk H Jr, Salzer M (2000) Wear debris from two different alumina-on-alumina total hip arthroplasties. J Bone Joint Surg Br 82:901

    Article  PubMed  CAS  Google Scholar 

  4. Davidson JA, Poggie RA, Mishra AK (1994) Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris. Biomed Mater Eng 4:213

    PubMed  CAS  Google Scholar 

  5. Iizuka T, Fujimoto H, Ono T (1987) A new material (single crystal sapphire screw) for internal fixation of the mandibular ramus. J Craniomaxillofac Surg 15:24

    PubMed  CAS  Google Scholar 

  6. Ishizuki M, Furuya K (1991) Clinical application of sapphire pins as an internal fixation device for the upper extremity. J Hand Surg [Am] 16:922

    CAS  Google Scholar 

  7. Kempf I, Semlitsch M (1994) Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball. Med Prog Technol 20:185

    PubMed  Google Scholar 

  8. Matsuda Y, Yamamuro T (1990) Metallosis due to abnormal abrasion of the femoral head in bipolar hip prosthesis. Implant retrieval and analysis in six cases. Arch Orthop Trauma Surg 109:284

    Article  PubMed  Google Scholar 

  9. Matziolis G, Perka C, Disch A (2003) Massive metallosis after revision of a fractured ceramic head onto a metal head. Arch Orthop Trauma Surg 123:48

    PubMed  Google Scholar 

  10. McNie CM, Barton DC, Fisher J, Stone MH (2000) Modeling of damage to articulating surfaces by third body particles in total joint replacements. J Mater Sci: Mater Med 11:569

    Article  CAS  Google Scholar 

  11. Ooi Y, Suka T, Satoh Y, Shibuya K, Ohki I, Masubuchi M, Mikanagi K (1982) Clinical experience of Al2O3 ceramics as a surgical implant. Int Orthop 6:93

    Article  PubMed  CAS  Google Scholar 

  12. Shikita T, Inoue A, Hamaguchi T, Oonishi H (1980) Experience of peripheral osteosynthesis using single crystal alumina ceramics screws. Z Orthop Ihre Grenzgeb 118:975

    Article  PubMed  CAS  Google Scholar 

  13. Su EP, Callander PW, Salvati EA (2003) The bubble sign: a new radiographic sign in total hip arthroplasty. J Arthroplasty 18:110

    Article  PubMed  Google Scholar 

  14. Tipper JL, Hatton A, Nevelos JE, Ingham E, Doyle C, Streicher R, Nevelos AB, Fisher J (2002) Alumina–alumina artificial hip joints. Part II; characterisation of the wear debris from in vitro hip joint simulations. Biomaterials 23:3441

    Article  PubMed  CAS  Google Scholar 

  15. Watanabe M, Okumura H, Kihara Y, Shibata T (1993) Metallosis caused by alumina ceramic screw fixation of grafted bone in a bipolar hip endoprosthesis. Arch Orthop Trauma Surg 112:296

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hidenobu Miki.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Miki, H., Sugano, N., Yamamura, M. et al. Serious metallosis of a metal head due to fragmented ceramic screws in a cemented THA. Arch Orthop Trauma Surg 126, 192–196 (2006). https://doi.org/10.1007/s00402-006-0112-y

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00402-006-0112-y

Keywords

Navigation