Abstract

Background

Distal biceps tendon ruptures are uncommon injuries with only around 300 cases reported in the literature. Current management tends to favour anatomical reinsertion of the tendon into the radial tuberosity, especially in young and active individuals. These injuries are commonly repaired using either a single anterior incision with suture anchors or the Boyd-Anderson dual incision technique.

Case report

We report the use of a bioabsorbable interference screw for the repair of distal biceps tendon rupture using a minimal incision technique. In this technique the avulsed tendon and a bioabsorbable screw are secured in a drill hole on the radial tuberosity using whip stitch and fibre wire sutures according to Biotenodesis system guidelines.

Conclusion

The technique described requires minimal volar dissection that is associated with a reduced number of synostosis and posterior interosseous nerve injuries. The bioabsorbable interference screw has all the advantages of being biodegradable and has been shown to have greater pullout strength than suture anchors. It is also a reasonable alternative to titanium screws in terms of primary fixation strength. The strong fixation provided allows early active motion and return to previous activities as seen in our case.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Aldridge JW, Bruno RJ, Straunch RJ, Rosenwasser MP (2000) Management of acute and chronic biceps tendon rupture. Hand Clin 16:497–503

    CAS  PubMed  Google Scholar 

  2. Barber FA, Deck MA (1995) The in vivo histology of an absorbable suture anchor: a preliminary report. Arthroscopy 11:77–81

    CAS  PubMed  Google Scholar 

  3. Berlet GC, Johnson JA, Milne AD, Patterson SD, King GJ (1998) Distal biceps brachii tendon repair. An in vitro biochemical study of tendon reattachment. Am J Sports Med 26:428–432

    CAS  PubMed  Google Scholar 

  4. Bernstein AD, Breslow MJ, Jazravi LM (2001) Distal biceps tendon ruptures: a historical perspective and current concepts. Am J Orthop 30:193–200

    CAS  PubMed  Google Scholar 

  5. Boileau P, Krishnan SG, Coste JS, Walch G (2002) Arthroscopic biceps tenodesis: a new technique using bioabsorbable interference screw fixation. Arthroscopy 18:1002–1012

    Article  PubMed  Google Scholar 

  6. Boyd HB, Anderson LD (1961) A method for reinsertion of the distal biceps brachii tendon. J Bone Joint Surg Am 43:1041–1043

    Google Scholar 

  7. D’Arco P, Sitler M, Kelly J, Moyer R, Marchetto P, Kimura I, Ryan J (1998) Clinical, functional, and radiographic assessments of the conventional and modified Boyd-Anderson surgical procedures for repair of distal biceps tendon ruptures. Am J Sports Med 26:254–261

    CAS  PubMed  Google Scholar 

  8. Lajtai G, Noszian I, Humer K, Unger F, Aitzetmuller G, Orthner E (1999) Serial magnetic resonance imaging evaluation of operative site after fixation of patellar tendon graft with bioabsorbable interference screws in anterior cruciate ligament reconstruction. Arthroscopy 15:709–718

    CAS  PubMed  Google Scholar 

  9. Lintner S, Fischer T (1996) Repair of distal biceps tendon using suture anchors and an anterior approach. Clin Orthop 322:116–119

    Article  PubMed  Google Scholar 

  10. McReynolds IS (1963) Avulsion of the insertion of the biceps brachii tendon and its surgical treatment. J Bone Joint Surg Am 45:1780–1781

    Google Scholar 

  11. Morgan CD, Gehrmann RM, Jayo MJ, Johnson CS (2002) Histological findings with a bioabsorbable anterior cruciate ligament interference screw explant after 2.5 years in vivo. Arthroscopy 18:E47

    Article  PubMed  Google Scholar 

  12. Morrey BF, Askew LJ, An KN, Dobyns JH (1985) Rupture of the distal tendon of the biceps brachii. A biomechanical study. J Bone Joint Surg Am 67:418–421

    CAS  PubMed  Google Scholar 

  13. Morrison KD, Hunt TR 3rd (2002) Comparing and contrasting methods for tenodesis of the ruptured distal biceps tendon. Hand Clin 18:169–178

    PubMed  Google Scholar 

  14. Norman WH (1985) Repair of avulsion of insertion of biceps brachii tendon. Clin Orthop 193:189–194

    PubMed  Google Scholar 

  15. Pereira DS, Kvitne RS, Liang M, Giacobetti FB, Ebramzadeh E (2002) Surgical repair of distal biceps tendon ruptures: a biomechanical comparison of two techniques. Am J Sports Med 30:432–436

    PubMed  Google Scholar 

  16. Ramsey ML (1999) Distal biceps tendon injuries: diagnosis and management. J Am Acad Orthop Surg 7:199–207

    CAS  PubMed  Google Scholar 

  17. Rantenen J, Orava S (1999) Rupture of the distal biceps tendon. A report of nineteen patients treated with anatomic reinsertion, and a meta-analysis of 147 cases found in literature. Am J Sports Med 27:128–132

    PubMed  Google Scholar 

  18. Rupp S, Krauss PW, Fritsch EW (1997) Fixation strength of a biodegradable interference screw and a press-fit technique in anterior cruciate ligament reconstruction with a BPTB graft. Arthroscopy 13:61–65

    CAS  PubMed  Google Scholar 

  19. Rupp S, Seil R, Schneider A, Kohn DM (1999) Ligament graft initial fixation strength using biodegradable interference screws. J Biomed Mater Res 48:70–74

    Article  CAS  PubMed  Google Scholar 

  20. Sotereanos DG, Pierce TD, Varitimidis SE (2000) A simplified method of repair for distal biceps tendon ruptures. J Shoulder Elbow Surg 9:227–233

    CAS  PubMed  Google Scholar 

  21. Straunch RJ (2001) Techniques of distal biceps tendon repair. Curr Opin Orthop 12:338–342

    Article  Google Scholar 

  22. Strauch RJ, Michelson H, Rosenwasser MP (1997) Repair of rupture of the distal tendon of the biceps brachii. Review of literature and report of three cases treated with a single anterior incision and suture anchors. Am J Orthop 26:151–156

    CAS  PubMed  Google Scholar 

  23. Szymankiewickz J, Ramesh FT, Bunker T (2003) Biotenodesis post: a novel technique for knotless arthroscopic cuff repair. British Elbow and Shoulder Society, 14th Annual Scientific Meeting, May 2003

    Google Scholar 

  24. Verhaven E, Huylebroek J, Van Nieuwenhuysen W, Van Overschelde J (1993) Surgical treatment of acute biceps tendon ruptures with a suture anchor. Acta Orthop Belg 59:426–429

    CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to W. Khan.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Khan, W., Agarwal, M. & Funk, L. Repair of distal biceps tendon rupture with the Biotenodesis screw. Arch Orthop Trauma Surg 124, 206–208 (2004). https://doi.org/10.1007/s00402-004-0639-8

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00402-004-0639-8

Keywords

Navigation