Abstract
Introduction
Foreign bodies in the esophagus are common in children. Time from ingestion to presentation is variable, and may not be known. Our center usually performs Foley catheter balloon extraction under fluoroscopy as the first step to attempt removal to prevent all patients from going to the operating room. The efficacy of this procedure has been reported. However, information is lacking about the relationship between presentation variables and the likelihood of success.
Methods
After IRB approval, we performed a retrospective single-center review from January 1988 to August 2011 of children with an esophageal foreign body. Pearson’s correlation was used to evaluate the relationship between variables and successful balloon extraction for P < 0.05. A logistic regression was done to evaluate for independence.
Results
819 patients presented with esophageal foreign bodies, with a mean age of 3.3 years. 572 patients underwent balloon extraction, 83 % successful. Mean ingestion duration was 16.6 h with fluoroscopy time of 2.3 min and mean number of attempts was 1.5. Successful balloon extraction had a negative correlation with refusal to eat, respiratory distress, cough, wheeze, upper respiratory infection symptoms, stridor, fever, duration of ingestion >1 day, unwitnessed ingestion, fluoroscopy time and number of balloon catheter attempts. There was a positive correlation between success and both age and duration of ingestion <1 day. Independent predictive factors were number of balloon catheter attempts.
Conclusions
Patients with longer duration of ingestion, symptoms from the foreign body and increased number of removal attempts have a decreased likelihood of success with balloon catheter extraction and should not undergo prolonged efforts of removal.
Similar content being viewed by others
References
Bronstein AC, Spyker DA, Cantilena LR Jr et al, American Association of Poison Control Centers (2008) 2007 Annual Report of the American Association of Poison Control Centers’ National Poison Data System (NPDS): 25th Annual Report. Clin Toxicol 46:927–1057
Waltzman ML (2006) Management of esophageal coins. Curr Opin Pediatr 18:571–574
Janik JS, Bailey WC, Burrington JD (1986) Occult coin perforation of the esophagus. J Pediatr Surg 21:794–797
Schunk JE, Harrison AM, Corneli HM et al (1994) Fluoroscopic Foley catheter removal of esophageal foreign bodies in children: experience with 415 episodes. Pediatrics 94:709–714
Little DC, Shah SR, St Peter SD et al (2006) Esophageal foreign bodies in the pediatric population: our first 500 cases. J Pediatr Surg 41:914–918
Morrow SE, Bickler SW, Kennedy AP et al (1998) Balloon extraction of esophageal foreign bodies in children. J Pediatr Surg 33:266–270
Rubin SZ, Mueller DL (1987) Removal of esophageal foreign bodies with a Foley balloon catheter under fluoroscopic control. CMAJ 137:125–127
Alexander W, Kadish JA, Dunbar JS (1969) Ingested foreign bodies in children. In: Kaufmann HJ (ed) Progress in pediatric radiology, 2nd edn. Yearbook Medical Publishers, Chicago, pp 256–285
Balci AE, Eren S, Eren MN (2004) Esophageal foreign bodies under cricopharyngeal level in children: an analysis of 1116 cases. Interact Cadiovasc Thorac Surg 3:14–18
Chang JH, Burrington JD (1973) Removal of coins from the esophagus: nothing new under the sun. Pediatrics 51:313
Rodriguez H, Passali GC, Gregori D et al (2012) Management of foreign bodies in the airway and oesophagus. Int J Pediatr Otorhinolaryngol 76:584–591
McNeill MB, Sperry SL, Crockett SD et al (2012) Epidemiology and management of oesophageal coin impaction in children. Dig Liver Dis 44:482–486
Jackson RM, Hawkins DB (1986) Coins in the esophagus. What is the best management? Int J Pediar Otorhinolaryngol 12:127–135
Hawkins DB (1990) Removal of blunt foreign bodies from the esophagus. Ann Otol Rhinol Laryngol 99:935–939
Korcok M (1982) No-confidence vote on catheter removal of foreign bodies. JAMA 247:3304
Ritter FN (1974) Questionable methods of foreign body treatment. Ann Otorhinolaryngol 83:729–733
Mariani PJ, Wagner DK (1986) Foley catheter extraction of blunt esophageal foreign bodies. J Emerg Med 4:301–306
Kelley JE, Leech MH, Carr MG (1993) A safe cost-effective protocol for the management of esophageal coins in children. J Pediatr Surg 28:898–900
O’Neill JA Jr, Holcomb GW Jr, Neblett WW (1983) Management of tracheobronchial and esophageal foreign bodies in childhood. J Pediatr Surg 18:475–479
Kirks DR (1992) Fluoroscopic catheter removal of blunt esophageal foreign bodies, a pediatric radiologist’s perspective. Pediatr Radiol 22:64–65
Campbell JB, Foley LC (1983) A safe alternative to endoscopic removal of blunt esophageal foreign bodies. Arch Otolaryngol 109:323–325
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Gasior, A.C., Knott, E.M., Sharp, S.W. et al. Predictive factors for successful balloon catheter extraction of esophageal foreign bodies. Pediatr Surg Int 29, 791–794 (2013). https://doi.org/10.1007/s00383-013-3331-7
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00383-013-3331-7