Filum terminale lipomas—the role of intraoperative neuromonitoring

  • Original Article
  • Published:
Child's Nervous System Aims and scope Submit manuscript

Abstract

Background

Filum terminale lipomas (FTL) represent a sub-type of spinal lipomas, where there is fatty infiltration of the filum. It becomes a surgical entity when it manifests as clinical or radiological tethered cord syndrome. Intraoperative neuromonitoring (IONM) has been suggested as a valuable tool in children for tethered cord surgeries. FTL is distinct and cannot be compared with complex tethered cord syndrome (TCS). Untethering an FTL is a relatively straightforward microsurgical exercise, usually based on anatomical findings. Neurological morbidity in FTL untethering is extremely low. The necessity of IONM in FTL has not been evaluated. The objective of this study was to identify the role of IONM in untethering an FTL

Methods

Available electronic data and case files were interrogated to identify children (0–18 years) who underwent an untethering of FTL between 2008 and 2019. We had a shift in our policy and tried to use IONM as often as possible in all tethered cord surgery from 2014. All children were categorised under ‘IONM implemented’ or ‘no IONM’ group. Outcomes analysed were as follows: (1) Clinical status on short-term and long-term follow-up, (2) alteration of surgical course by IONM and (3) complications specifically associated with IONM

Results

Among 80 children included in this study, IONM was implemented in 37 children and 43 children underwent untethering without IONM. 32.5% of children were ‘syndromic’. Seventy-five percent of children were under age 3 years during surgery. Both groups (No IONM vs. IONM implemented) were well matched in most variables. Majority of ‘no IONM’ surgeries were performed prior to 2014. There was no neurological morbidity in the entire cohort. Mean duration of follow-up was 49.10 (± 33.67) months. Short-term and long-term clinical status remained stable in both cohorts. In 16 children, the filum was stimulated. Based on our protocol, majority had a negative response. One child showed a positive response, contradicted by thorough microscopic inspection. Despite a positive response, the filum was untethered. IONM was not associated with any complication in this study.

Conclusion

FTL untethering is an inherently low-risk microsurgery in experienced hands with rarely reported neurological morbidity. IONM may not be required for all FTL and may be used more judiciously.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

Abbreviations

FTL:

Filum terminale lipoma

TCS:

Tethered cord syndrome

IONM:

Intraoperative neuromonitoring

MEP:

Motor evoked potential

SSEP:

Somato-sensory evoked potentials

EMG:

Electromyography

CMAP:

Compound muscle action potential

TIVA:

Total intravenous anaesthesia

References

  1. Morota N, Ihara S, Ogiwara H (2017) New classification of spinal lipomas based on embryonic stage. J Neurosurg Pediatr 19:428–439. https://doi.org/10.3171/2016.10.PEDS16247

    Article  Google Scholar 

  2. Blount JP, Elton S (2001) Spinal lipomas. Neurosurg Focus 10:1–13

    Article  Google Scholar 

  3. Cools MJ, Al-Holou WN, Stetler WR et al (2014) Filum terminale lipomas: Imaging prevalence, natural history, and conus position - clinical article. J Neurosurg Pediatr 13:559–567. https://doi.org/10.3171/2014.2.PEDS13528

    Article  PubMed  Google Scholar 

  4. O’Neill BR, Yu AK, Tyler-Kabara EC (2010) Prevalence of tethered spinal cord in infants with VACTERL: clinical article. J Neurosurg Pediatr 6:177–182. https://doi.org/10.3171/2010.5.PEDS09428

    Article  PubMed  Google Scholar 

  5. Kuo MF, Tsai Y, Hsu WM, Chen RS, Tu YK, Wang HS (2007) Tethered spinal cord and VACTERL association. J Neurosurg 106:201–204. https://doi.org/10.3171/ped.2007.106.3.201

    Article  PubMed  Google Scholar 

  6. Ostling LR, Bierbrauer KS, Kuntz C IV (2012) Outcome, reoperation, and complications in 99 consecutive children operated for tight or fatty filum. World Neurosurg 77:187–191. https://doi.org/10.1016/j.wneu.2011.05.017

    Article  PubMed  Google Scholar 

  7. Vassilyadi M, Tataryn Z, Merziotis M (2013) Retethering in children after sectioning of the filum terminale. Pediatr Neurosurg 48:335–341. https://doi.org/10.1159/000353477

    Article  Google Scholar 

  8. Von Koch CS, Quinones-Hinojosa A, Gulati M et al (2002) Clinical outcome in children undergoing tethered cord release utilizing intraoperative neurophysiological monitoring. Pediatr Neurosurg 37:81–86. https://doi.org/10.1159/000065109

    Article  Google Scholar 

  9. Yong RL, Habrock-Bach T, Vaughan M, Kestle JR, Steinbok P (2011) Symptomatic retethering of the spinal cord after section of a tight filum terminale. Neurosurgery 68:1594–1601. https://doi.org/10.1227/NEU.0b013e31821246c6

    Article  PubMed  Google Scholar 

  10. Hoving EW, Haitsma E, Ophuis CMCO, Journée HL (2011) The value of intraoperative neurophysiological monitoring in tethered cord surgery. Child’s Nerv Syst 27:1445–1452. https://doi.org/10.1007/s00381-011-1471-4

    Article  Google Scholar 

  11. Kothbauer KF, Deletis V (2010) Intraoperative neurophysiology of the conus medullaris and cauda equina. Child’s Nerv Syst 26:247–253. https://doi.org/10.1007/s00381-009-1020-6

    Article  Google Scholar 

  12. Kothbauer KF, Novak K (2004) Intraoperative monitoring for tethered cord surgery: an update. Neurosurg Focus 16:1–5. https://doi.org/10.3171/foc.2004.16.2.1

    Article  Google Scholar 

  13. Sala F, Squintani G, Tramontano V, Arcaro C, Faccioli F, Mazza C (2013) Intraoperative neurophysiology in tethered cord surgery: techniques and results. Child’s Nerv Syst 29:1611–1624. https://doi.org/10.1007/s00381-013-2188-3

    Article  Google Scholar 

  14. Halevi PD, Udayakumaran S, Ben-Sira L, Constantini S (2011) The value of postoperative MR in tethered cord: a review of 140 cases. Child’s Nerv Syst 27:2159–2162. https://doi.org/10.1007/s00381-011-1578-7

    Article  Google Scholar 

  15. Sala F, Bricolo A, Faccioli F, et al (2007) Surgery for intramedullary spinal cord tumors: the role of intraoperative (neurophysiological) monitoring. In: European Spine Journal. Springer, p 130

  16. Hadley MN, Shank CD, Rozzelle CJ, Walters BC (2017) Guidelines for the use of electrophysiological monitoring for surgery of the human spinal column and spinal cord. Neurosurgery 81:713–732

    Article  Google Scholar 

  17. Sala F, Palandri G, Basso E, Lanteri P, Deletis V, Faccioli F, Bricolo A (2006) Motor evoked potential monitoring improves outcome after surgery for intramedullary spinal cord tumors: a historical control study. Neurosurgery 58:1129–1141. https://doi.org/10.1227/01.NEU.0000215948.97195.58

    Article  PubMed  Google Scholar 

  18. Yi YG, Kim K, Shin HI, Bang MS, Kim HS, Choi J, Wang KC, Kim SK, Lee JY, Phi JH, Seo HG (2019) Feasibility of intraoperative monitoring of motor evoked potentials obtained through transcranial electrical stimulation in infants younger than 3 months. J Neurosurg Pediatr 23:758–766. https://doi.org/10.3171/2019.1.PEDS18674

    Article  Google Scholar 

  19. Gavaret M, Pesenti S, Choufani E, Pennaroli D, Bollini G, Jouve JL (2016) Intraoperative spinal cord monitoring in children under 4 years old. Eur Spine J 25:1847–1854. https://doi.org/10.1007/s00586-016-4553-x

    Article  PubMed  Google Scholar 

  20. Quiñones-Hinojosa A, Gadkary CA, Gulati M, von Koch CS, Lyon R, Weinstein PR, Yingling CD (2004) Neurophysiological monitoring for safe surgical tethered cord syndrome release in adults. Surg Neurol 62:127–133. https://doi.org/10.1016/j.surneu.2003.11.025

    Article  PubMed  Google Scholar 

  21. Selçuki M, Vatansever S, Inan S, Erdemli E, Bağdatoğlu C, Polat A (2003) Is a filum terminale with a normal appearance really normal? Child’s Nerv Syst 19:3–10. https://doi.org/10.1007/s00381-002-0665-1

    Article  Google Scholar 

  22. Pierre-Kahn A, Zerah M, Renier D, Cinalli G, Sainte-Rose C, Lellouch-Tubiana A, Brunelle F, Merrer ML, Giudicelli Y, Pichon J, Kleinknecht B, Nataf F (1997) Congenital lumbosacral lipomas. Child’s Nerv Syst 13:298–335

    Article  CAS  Google Scholar 

  23. Brophy JD, Sutton LN, Zimmerman RA, Bury E, Schut L (1989) Magnetic resonance imaging of lipomyelomeningocele and tethered cord. Neurosurgery:336. https://doi.org/10.1097/00006123-198909000-00002

  24. Kumar GSS, Rajshekhar V, Babu KS (2006) Intraoperative mapping of sacral nervous system (S2 - 4). Br J Neurosurg 20:396–402. https://doi.org/10.1080/02688690601101481

    Article  PubMed  Google Scholar 

  25. Gaddam SSK, Santhi V, Babu S, Chacko G, Baddukonda RA, Rajshekhar V (2012) Gross and microscopic study of the filum terminale: does the filum contain functional neural elements? Laboratory investigation. J Neurosurg Pediatr 9:86–92. https://doi.org/10.3171/2011.10.PEDS11102

    Article  PubMed  Google Scholar 

  26. Saker E, Henry BM, Tomaszewski KA, Loukas M, Iwanaga J, Oskouian RJ, Tubbs RS (2017) The filum terminale internum and externum: a comprehensive review. J Clin Neurosci 40:6–13. https://doi.org/10.1016/j.jocn.2016.12.020

    Article  PubMed  Google Scholar 

  27. Laratta JL, Shillingford JN, Ha A et al (2018) Utilization of intraoperative neuromonitoring throughout the United States over a recent decade: an analysis of the nationwide inpatient sample. J Spine Surg 4:211–219. https://doi.org/10.21037/jss.2018.04.05

    Article  PubMed  PubMed Central  Google Scholar 

  28. Schraag S, Pradelli L, Alsaleh AJO, Bellone M, Ghetti G, Chung TL, Westphal M, Rehberg S (2018) Propofol vs. inhalational agents to maintain general anaesthesia in ambulatory and in-patient surgery: a systematic review and meta-analysis. BMC Anesthesiol 18:162. https://doi.org/10.1186/s12871-018-0632-3

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgement

We thank Dr Swetha Kumar for editorial assistance.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Shlomi Constantini.

Ethics declarations

Conflict of interest

None declared

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lalgudi Srinivasan, H., Valdes-Barrera, P., Agur, A. et al. Filum terminale lipomas—the role of intraoperative neuromonitoring. Childs Nerv Syst 37, 931–939 (2021). https://doi.org/10.1007/s00381-020-04856-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00381-020-04856-4

Keywords

Navigation