Abstract
We investigated the agreement between remote dielectric sensing (ReDS) system, which is a recently introduced non-invasive technology to quantify the degree of pulmonary congestion, and lung ultrasound (LUS), which is a gold standard to assess the existence of severe pulmonary congestion. Consecutive patients who were hospitalized to examine the cause of heart failure and treat their heart failure in our institute were prospectively included. They received LUS and simultaneous ReDS measurements. Three or more B-lines at each LUS zone was assigned to B-profile positive, indicating the existence of significant pulmonary congestion. ReDS values ≥ 35% were defined as significant pulmonary congestion. A total of 19 heart failure patients were included (77 years, 13 men). Plasma B-type natriuretic peptide level was 131 (36, 416) pg/ml. Three patients had B-profile, indicating significant pulmonary congestion, and two of them had ≥ 35% of ReDS (sensitivity 66.7%, specificity 87.5%, and negative predictive value 93.3%). Most of the patients (79%) had lower B-lines below 3 and did not satisfy the criteria of B-profile, irrespective of wide ranges of ReDS values. ReDS system had as acceptable predictability as LUS in assessing the existence of significant pulmonary congestion. ReDS would be recommended to rule out significant pulmonary congestion or quantify the degree of less significant pulmonary congestion.
Similar content being viewed by others
References
Girerd N, Seronde MF, Coiro S, Chouihed T, Bilbault P, Braun F, Kenizou D, Maillier B, Nazeyrollas P, Roul G, Fillieux L, Abraham WT, Januzzi J Jr, Sebbag L, Zannad F, Mebazaa A, Rossignol P, Rossignol P; INI-CRCT, Great Network, and the EF-HF Group (2018) Integrative assessment of congestion in heart failure throughout the patient journey. JACC Heart Fail 6(4):273–285
Yuriditsky E, Horowitz JM, Panebianco NL, Sauthoff H, Saric M (2021) Lung ultrasound imaging: a primer for echocardiographers. J Am Soc Echocardiogr 34(12):1231–1241
Amir O, Rappaport D, Zafrir B, Abraham WT (2013) A novel approach to monitoring pulmonary congestion in heart failure: initial animal and clinical experiences using remote dielectric sensing technology. Congest Heart Fail 19(3):149–155
Čelutkienė J, Lainscak M, Anderson L, Gayat E, Grapsa J, Harjola VP, Manka R, Nihoyannopoulos P, Filardi PP, Vrettou R, Anker SD, Filippatos G, Mebazaa A, Metra M, Piepoli M, Ruschitzka F, Zamorano JL, Rosano G, Seferovic P (2020) Imaging in patients with suspected acute heart failure: timeline approach position statement on behalf of the heart failure association of the European society of cardiology. Eur J Heart Fail 22(2):181–195
Imamura T, Gonoi W, Hori M, Ueno Y, Narang N, Onoda H, Tanaka S, Nakamura M, Kataoka N, Ushijima R, Sobajima M, Fukuda N, Ueno H, Kinugawa K (2021) Validation of noninvasive remote dielectric sensing system to quantify lung fluid levels. J Clin Med 11(1):164
Abraham WT, Bensimhon D, Pinney SP, Feitell SC, Peacock WF, Amir O, Burkhoff D (2021) Patient monitoring across the spectrum of heart failure disease management 10 years after the CHAMPION trial. ESC Heart Fail 8(5):3472–3482
Volpicelli G, Elbarbary M, Blaivas M, Lichtenstein DA, Mathis G, Kirkpatrick AW, Melniker L, Gargani L, Noble VE, Via G, Dean A, Tsung JW, Soldati G, Copetti R, Bouhemad B, Reissig A, Agricola E, Rouby JJ, Arbelot C, Liteplo A, Sargsyan A, Silva F, Hoppmann R, Breitkreutz R, Seibel A, Neri L, Storti E, Petrovic T (2012) International liaison committee on lung ultrasound (ILC-LUS) for international consensus conference on lung ultrasound (ICC-LUS) (2012) international evidence-based recommendations for point-of-care lung ultrasound. Intensive Care Med 38(4):577–591
Conangla L, Domingo M, LupÓn J, Wilke A, JuncÀ G, Tejedor X, Volpicelli G, Evangelista L, Pera G, Toran P, Mas A, Cediel G, VerdÚ JM, Bayes-Genis A (2020) Lung ultrasound for heart failure diagnosis in primary care. J Card Fai 26(10):824–831
Amir O, Azzam ZS, Gaspar T, Faranesh-Abboud S, Andria N, Burkhoff D, Abbo A, Abraham WT (2016) Validation of remote dielectric sensing (ReDS™) technology for quantification of lung fluid status: comparison to high resolution chest computed tomography in patients with and without acute heart failure. Int J Cardiol 221:841–846
Imamura T, Hori M, Ueno Y, Narang N, Onoda H, Tanaka S, Nakamura M, Kataoka N, Sobajima M, Fukuda N, Ueno H, Kinugawa K (2022) Association between lung fluid levels estimated by remote dielectric sensing values and invasive hemodynamic measurements. J Clin Med 11(5):1208
Yang F, Wang Q, Zhang L, Ma Y, Chen Q (2021) Prognostic value of pulmonary oedema assessed by lung ultrasound in patient with acute heart failure. Heart Vessels 36(4):518–527
Acknowledgements
None.
Funding
None.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
IRB information
The present study was approved by the Ethics Committee of the University of Toyama (Reference number: MTK2020007, May 3. 2021).
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Izumida, T., Imamura, T. & Kinugawa, K. Remote dielectric sensing and lung ultrasound to assess pulmonary congestion. Heart Vessels 38, 517–522 (2023). https://doi.org/10.1007/s00380-022-02190-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00380-022-02190-0