Ablation index-guided high-power vs. moderate-power cavotricuspid isthmus ablation

  • Original Article
  • Published:
Heart and Vessels Aims and scope Submit manuscript

Abstract

Ablation index (AI)-guided ablation is useful for pulmonary vein isolation (PVI) and cavotricuspid isthmus (CTI) ablation. However, the impact of radiofrequency (RF) application power on CTI ablation with a fixed target AI remains unclear. One-hundred-thirty drug-refractory atrial fibrillation and/or atrial flutter patients who underwent AI-guided CTI ablation with or without PVI between July 2020 and August 2021 were randomly assigned to high-power (45 W) and moderate-power (35 W) groups. We performed CTI ablation with the same target AI value in both groups: 500 for the anterior 1/3 segments and 450 for the posterior 2/3 segments. In total, first-pass conduction block of the CTI was obtained in 111 patients (85.4%), with 7 patients (5.4%) showing CTI reconnection. The rate of first-pass conduction block was significantly higher in the 45 W group (61/65, 93.8%) than in the 35 W group (50/65, 76.9%, P = 0.01). CTI ablation and CTI fluoroscopy time were significantly shorter in the 45 W group than in the 35 W group (CTI ablation time: 192.3 ± 84.8 vs. 319.8 ± 171.4 s, P < 0.0001; CTI fluoroscopy time: 125.2 ± 122.4 vs. 171.2 ± 124.0 s, P = 0.039). Although there was no significant difference, steam pops were identified in two patients from the 45 W group at the anterior segment of the CTI. The 45 W ablation strategy was faster and provided a higher probability of first-pass conduction block than the 35 W ablation strategy for CTI ablation with a fixed AI target.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

  1. Asirvatham SJ (2009) Correlative anatomy and electrophysiology for the interventional electrophysiologist: right atrial flutter. J Cardiovasc Electrophysiol 20:113–122

    Article  Google Scholar 

  2. Ikeda A, Nakagawa H, Lambert H, Shah DC, Fonck E, Yulzari A, Sharma T, Pitha JV, Lazzara R, Jackman WM (2014) Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: electrogram amplitude, impedance, and electrode temperature are poor predictors of electrode-tissue contact force and lesion size. Circ Arrhythm Electrophysiol 7:1174–1180

    Article  Google Scholar 

  3. Das M, Loveday JJ, Wynn GJ, Gomes S, Saeed Y, Bonnett LJ, Waktare JEP, Todd DM, Hall MCS, Snowdon RL, Modi S, Gupta D (2017) Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values. Europace 19:775–783

    Google Scholar 

  4. Hussein A, Das M, Chaturvedi V, Asfour IK, Daryanani N, Morgan M, Ronayne C, Shaw M, Snowdon R, Gupta D (2017) Prospective use of Ablation Index targets improves clinical outcomes following ablation for atrial fibrillation. J Cardiovasc Electrophysiol 28:1037–1047

    Article  Google Scholar 

  5. Taghji P, El Haddad M, Phlips T, Wolf M, Knecht S, Vandekerckhove Y, Tavernier R, Nakagawa H, Duytschaever M (2018) Evaluation of a strategy aiming to enclose the pulmonary veins with contiguous and optimized radiofrequency lesions in paroxysmal atrial fibrillation: a pilot study. JACC Clin Electrophysiol 4:99–108

    Article  Google Scholar 

  6. Zhang T, Wang Y, Han Z, Zhao H, Liang Z, Wang Y, Wu Y, Ren X (2019) Cavotricuspid isthmus ablation using ablation index in typical right atrial flutter. J Cardiovasc Electrophysiol 30:2414–2419

    Article  Google Scholar 

  7. Viola G, Stabile G, Bandino S, Rossi L, Marrazzo N, Pecora D, Bottoni N, Solimene F, Schillaci V, Scaglione M, Ocello S, Baiocchi C, Santoro A, Donzelli S, De Ruvo E, Lavalle C, Sanchez-Gomez JM, Pastor JFA, Grandio PC, Ferraris F, Castro A, Rebellato L, Marchese P, Adao L, Primo J, Barra S, Casu G (2021) Safety, efficacy, and reproducibility of cavotricuspid isthmus ablation guided by the ablation index: acute results of the FLAI study. Europace 23:264–270

    Article  Google Scholar 

  8. Winkle RA, Mohanty S, Patrawala RA, Mead RH, Kong MH, Engel G, Salcedo J, Trivedi CG, Gianni C, Jais P, Natale A, Day JD (2019) Low complication rates using high power (45–50 W) for short duration for atrial fibrillation ablations. Heart Rhythm 16:165–169

    Article  Google Scholar 

  9. Berte B, Hilfiker G, Russi I, Moccetti F, Cuculi F, Toggweiler S, Ruschitzka F, Kobza R (2019) Pulmonary vein isolation using a higher power shorter duration CLOSE protocol with a surround flow ablation catheter. J Cardiovasc Electrophysiol 30:2199–2204

    Article  Google Scholar 

  10. Winkle RA (2021) HPSD ablation for AF high-power short-duration RF ablation for atrial fibrillation: a review. J Cardiovasc Electrophysiol 32:2813–2823

    Article  Google Scholar 

  11. Ravi V, Poudyal A, Abid QU, Larsen T, Krishnan K, Sharma PS, Trohman RG, Huang HD (2021) High-power short duration vs. conventional radiofrequency ablation of atrial fibrillation: a systematic review and meta-analysis. Europace 23:710–721

    Article  Google Scholar 

  12. Okamatsu H, Koyama J, Sakai Y, Negishi K, Hayashi K, Tsurugi T, Tanaka Y, Nakao K, Sakamoto T, Okumura K (2019) High-power application is associated with shorter procedure time and higher rate of first-pass pulmonary vein isolation in ablation index-guided atrial fibrillation ablation. J Cardiovasc Electrophysiol 30:2751–2758

    Article  Google Scholar 

  13. Jaïs P, Haïssaguerre M, Shah DC, Takahashi A, Hocini M, Lavergne T, Lafitte S, Le Mouroux A, Fischer B, Clémenty J (1998) Successful irrigated-tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation. Circulation 98:835–838

    Article  Google Scholar 

  14. Atiga WL, Worley SJ, Hummel J, Berger RD, Gohn DC, Mandalakas NJ, Kalbfleisch S, Halperin H, Donahue K, Tomaselli G, Calkins H, Daoud E (2002) Prospective randomized comparison of cooled radiofrequency versus standard radiofrequency energy for ablation of typical atrial flutter. Pacing Clin Electrophysiol 25:1172–1178

    Article  Google Scholar 

  15. Scavée C, Jaïs P, Hsu LF, Sanders P, Hocini M, Weerasooriya R, Macle L, Raybaud F, Clementy J, Haïssaguerre M (2004) Prospective randomised comparison of irrigated-tip and large-tip catheter ablation of cavotricuspid isthmus-dependent atrial flutter. Eur Heart J 25:963–969

    Article  Google Scholar 

  16. Ventura R, Klemm H, Lutomsky B, Demir C, Rostock T, Weiss C, Meinertz T, Willems S (2004) Pattern of isthmus conduction recovery using open cooled and solid large-tip catheters for radiofrequency ablation of typical atrial flutter. J Cardiovasc Electrophysiol 15:1126–1130

    Article  Google Scholar 

  17. Ilg KJ, Kühne M, Crawford T, Chugh A, Jongnarangsin K, Good E, Pelosi F Jr, Bogun F, Morady F, Oral H (2011) Randomized comparison of cavotricuspid isthmus ablation for atrial flutter using an open irrigation-tip versus a large-tip radiofrequency ablation catheter. J Cardiovasc Electrophysiol 22:1007–1012

    Article  Google Scholar 

  18. Saremi F, Pourzand L, Krishnan S, Ashikyan O, Gurudevan SV, Narula J, Kaushal K, Raney A (2008) Right atrial cavotricuspid isthmus: anatomic characterization with multi-detector row CT. Radiology 247:658–668

    Article  Google Scholar 

  19. Kajihara K, Nakano Y, Hirai Y, Ogi H, Oda N, Suenari K, Makita Y, Sairaku A, Tokuyama T, Motoda C, Fujiwara M, Watanabe Y, Kiguchi M, Kihara Y (2013) Variable procedural strategies adapted to anatomical characteristics in catheter ablation of the cavotricuspid isthmus using a preoperative multidetector computed tomography analysis. J Cardiovasc Electrophysiol 24:1344–1351

    Article  Google Scholar 

  20. Chikata A, Kato T, Usuda K, Fujita S, Maruyama M, Otowa KI, Takashima SI, Murai H, Usui S, Furusho H, Kaneko S, Takamura M (2019) Coronary sinus catheter placement via left cubital vein for phrenic nerve stimulation during pulmonary vein isolation. Heart Vessels 34:1710–1716

    Article  Google Scholar 

  21. Baccillieri MS, Rizzo S, De Gaspari M, Paradiso B, Thiene G, Verlato R, Basso C (2019) Anatomy of the cavotricuspid isthmus for radiofrequency ablation in typical atrial flutter. Heart Rhythm 16:1611–1618

    Article  Google Scholar 

  22. Kwon HJ, Lee SS, Park YJ, Park SJ, Park KM, Kim JS, On YK (2020) Effectiveness and safety of high-power and short-duration ablation for cavotricuspid isthmus ablation in atrial flutter. Pacing Clin Electrophysiol 43:941–946

    Article  Google Scholar 

  23. Barkagan M, Contreras-Valdes FM, Leshem E, Buxton AE, Nakagawa H, Anter E (2018) High-power and short-duration ablation for pulmonary vein isolation: Safety, efficacy, and long-term durability. J Cardiovasc Electrophysiol 29:1287–1296

    Article  Google Scholar 

  24. Bourier F, Duchateau J, Vlachos K, Lam A, Martin CA, Takigawa M, Kitamura T, Frontera A, Cheniti G, Pambrun T, Klotz N, Denis A, Derval N, Cochet H, Sacher F, Hocini M, Haïssaguerre M, Jais P (2018) High-power short-duration versus standard radiofrequency ablation: Insights on lesion metrics. J Cardiovasc Electrophysiol 29:1570–1575

    Article  Google Scholar 

  25. Leshem E, Zilberman I, Tschabrunn CM, Barkagan M, Contreras-Valdes FM, Govari A, Anter E (2018) High-power and short-duration ablation for pulmonary vein isolation: biophysical characterization. JACC Clin Electrophysiol 4:467–479

    Article  Google Scholar 

  26. Yavin HD, Leshem E, Shapira-Daniels A, Sroubek J, Barkagan M, Haffajee CI, Cooper JM, Anter E (2020) Impact of High-Power Short-Duration Radiofrequency Ablation on Long-Term Lesion Durability for Atrial Fibrillation Ablation. JACC Clin Electrophysiol 6:973–985

    Article  Google Scholar 

Download references

Funding

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Takeshi Kato.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chikata, A., Kato, T., Usuda, K. et al. Ablation index-guided high-power vs. moderate-power cavotricuspid isthmus ablation. Heart Vessels 38, 90–95 (2023). https://doi.org/10.1007/s00380-022-02125-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00380-022-02125-9

Keywords

Navigation