Network meta-analysis of new-generation valves for transcatheter aortic valve implantation

  • Original Article
  • Published:
Heart and Vessels Aims and scope Submit manuscript

Abstract

To comprehensively compare and rank new-generation valves (NGVs) for transcatheter aortic valve implantation, we performed a network meta-analysis (NMA) of all eligible comparative studies. MEDLINE and EMBASE were searched through September 2018. We included all studies comparing 4 NGVs (ACURATE, Evolut R, Lotus, and SAPIEN 3) and an early generation valve (CoreValve) as the reference transcatheter heart valve (THV) each other and reporting at least one of postprocedural incidence of all-cause death, ≥ moderate aortic regurgitation (AR), and new permanent pacemaker implantation (PMI). To compare different THVs, a random-effects restricted-maximum-likelihood NMA based on a frequentist framework for indirect and mixed comparisons was used. Using surface under the cumulative ranking curve (SUCRA), the relative ranking probability of each THV was estimated and the hierarchy of competing THVs was obtained. We identified 29 eligible studies enrolling a total of 17,817 patients. In accordance with the estimated SUCRA probability, SAPIEN 3 was the best effective for a reduction in death (80.6%) and the second best for decreased ≥ moderate AR (74.4%) and PMI (74.1%) compared with the other THVs. Lotus was ranked the best for a reduction in ≥ moderate AR (94.5%;), whereas the worst for decreased PMI (1.2%) and the second worst for a reduction in mortality (38.6%). ACURATE was the best for decreased PMI (99.2%) and the second best for a reduction in mortality (77.9%). As a whole, SAPIEN 3 may be the best effective NGV among the 4 examined NGVs (ACURATE, Evolut R, Lotus, and SAPIEN 3).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9

Similar content being viewed by others

References

  1. Ando T, Takagi H, Telila T, Afonso L (2018) Comparison of outcomes in new-generation versus early-generation heart valve in transcatheter aortic valve implantation: a systematic review and meta-analysis. Cardiovasc Revasc Med 19:186–191

    Article  Google Scholar 

  2. Akodad M, Lattuca B, Agullo A, Macia JC, Gandet T, Marin G, Iemmi A, Vernhet H, Schmutz L, Nagot N, Albat B, Cayla G, Leclercq F (2018) Prognostic impact of calcium score after transcatheter aortic valve implantation performed with new generation prosthesis. Am J Cardiol 121:1225–1230

    Article  CAS  Google Scholar 

  3. Asch FM, Vannan MA, Singh S, Khandheria B, Little SH, Allocco DJ, Meredith IT, Feldman TE, Reardon MJ, Weissman NJ (2018) Hemodynamic and echocardiographic comparison of the lotus and corevalve transcatheter aortic valves in patients with high and extreme surgical risk: an analysis from the reprise iii randomized controlled trial. Circulation 137:2557–2567

    Article  Google Scholar 

  4. Eitan A, Witt J, Stripling J, Haselbach T, Rieß FC, Schofer J (2018) Performance of the Evolut-R 34 mm versus Sapien-3 29 mm in Transcatheter aortic valve replacement patients with larger annuli: Early outcome results of Evolut-R 34 mm as compared with Sapien-3 29 mm in patients with Annuli ≥26 mm. Catheter Cardiovasc Interv 5:5. https://doi.org/10.1002/ccd.27588

    Article  Google Scholar 

  5. Enríquez-Rodríguez E, Amat-Santos IJ, Jiménez-Quevedo P, Martín-Morquecho I, Tirado-Conte G, Pérez-Vizcayno MJ, Gómez de Diego JJ, Arnold R, Aldazábal A, Rojas P, de Agustín A, Del Trigo M, Gutiérrez H, San Román JA, Macaya C, Nombela-Franco L (2018) Comparison of the hemodynamic performance of the balloon-expandable SAPIEN 3 versus self-expandable evolut R transcatheter valve: a case-matched study. Rev Esp Cardiol (Engl Ed) 71:735–742

    Article  Google Scholar 

  6. Giannini C, De Carlo M, Tamburino C, Ettori F, Latib AM, Bedogni F, Bruschi G, Presbitero P, Poli A, Fabbiocchi F, Violini R, Trani C, Giudice P, Barbanti M, Adamo M, Colombo P, Benincasa S, Agnifili M, Petronio AS (2017) Transcathether aortic valve implantation with the new repositionable self-expandable Evolut R versus CoreValve system: a case-matched comparison. Int J Cardiol 243:126–131

    Article  Google Scholar 

  7. Gomes B, Geis NA, Chorianopoulos E, Meder B, Leuschner F, Katus HA, Bekeredjian R (2017) Improvements of procedural results with a new-generation self-expanding transfemoral aortic valve prosthesis in comparison to the old-generation device. J Interv Cardiol 30:72–78

    Article  Google Scholar 

  8. Gonska B, Seeger J, Baarts J, Rodewald C, Scharnbeck D, Rottbauer W, Wöhrle J (2017) The balloon-expandable Edwards Sapien 3 valve is superior to the self-expanding Medtronic CoreValve in patients with severe aortic stenosis undergoing transfemoral aortic valve implantation. J Cardiol 69:877–882

    Article  Google Scholar 

  9. Gooley RP, Talman AH, Cameron JD, Lockwood SM, Meredith IT (2015) Comparison of self-expanding and mechanically expanded transcatheter aortic valve prostheses. JACC Cardiovasc Interv 8:962–971

    Article  Google Scholar 

  10. Husser O, Kim WK, Pellegrini C, Holzamer A, Walther T, Mayr PN, Joner M, Kasel AM, Trenkwalder T, Michel J, Rheude T, Kastrati A, Schunkert H, Burgdorf C, Hilker M, Möllmann H, Hengstenberg C (2017) Multicenter comparison of novel self-expanding versus balloon-expandable transcatheter heart valves. JACC Cardiovasc Interv 10:2078–2087

    Article  Google Scholar 

  11. Jarr KU, Leuschner F, Meder B, Katus HA, Bekeredjian R, Chorianopoulos E (2017) Initial single-center experience with the fully repositionable transfemoral lotus aortic valve system. J Invasive Cardiol 29:30–35

    PubMed  Google Scholar 

  12. Jatene T, Castro-Filho A, Meneguz-Moreno RA, Siqueira DA, Abizaid AAC, Ramos AIO, Arrais M, Le Bihan DCS, Barretto RBM, Moreira AC, Sousa AGMR, Eduardo Sousa J (2017) Prospective comparison between three TAVR devices: ACURATE neo vs. CoreValve vs. SAPIEN XT. A single heart team experience in patients with severe aortic stenosis. Catheter Cardiovasc Interv 90:139–146

    Article  Google Scholar 

  13. Kalogeras K, Kabir T, Mittal T, Mirsadraee S, Skondras E, Rahman Haley S, Zuhair M, Vavuranakis M, Tousoulis D, Dalby M, Panoulas V (2018) Real-world comparison of the new 34 mm self-expandable transcatheter aortic prosthesis Evolut R to its 31 mm core valve predecessor. Catheter Cardiovasc Interv 5:5. https://doi.org/10.1002/ccd.27862

    Article  Google Scholar 

  14. Landes U, Bental T, Barsheshet A, Assali A, Vaknin Assa H, Levi A, Orvin K, Kornowski R (2017) Comparative matched outcome of Evolut-R vs CoreValve transcatheter aortic valve implantation. J Invasive Cardiol 29:69–74

    PubMed  Google Scholar 

  15. Mauri V, Kim WK, Abumayyaleh M, Walther T, Moellmann H, Schaefer U, Conradi L, Hengstenberg C, Hilker M, Wahlers T, Baldus S, Rudolph V, Madershahian N, Rudolph TK (2017) Short-term outcome and hemodynamic performance of next-generation self-expanding versus balloon-expandable transcatheter aortic valves in patients with small aortic annulus: a multicenter propensity-matched comparison. Circ Cardiovasc Interv 10:10

    Article  Google Scholar 

  16. Musa TA, Uddin A, Dobson LE, Swoboda PP, Garg P, Foley JRJ, Malkin C, Plein S, Blackman DJ, Greenwood JP (2018) Cardiovascular magnetic resonance assessment of 1st generation CoreValve and 2nd generation Lotus valves. J Interv Cardiol 31:391–399

    Article  Google Scholar 

  17. Nai Fovino L, Badawy MRA, Fraccaro C, D'Onofrio A, Purita PAM, Frigo AC, Tellaroli P, Mauro A, Tusa M, Napodano M, Gerosa G, Iliceto S, Bedogni F, AbdelRheim AER, Tarantini G (2018) Transfemoral aortic valve implantation with new-generation devices: the repositionable Lotus vs. the balloon-expandable Edwards Sapien 3 valve. J Cardiovasc Med (Hagerstown) 19:655–663

    Article  Google Scholar 

  18. Noble S, Stortecky S, Heg D, Tueller D, Jeger R, Toggweiler S, Ferrari E, Nietlispach F, Taramasso M, Maisano F, Grünenfelder J, Jüni P, Huber C, Carrel T, Windecker S, Wenaweser P, Roffi M (2017) Comparison of procedural and clinical outcomes with Evolut R versus Medtronic CoreValve: a Swiss TAVI registry analysis. EuroIntervention 12:e2170–e2176

    Article  Google Scholar 

  19. Perrin N, Perrin T, Hachulla AL, Frei A, Müller H, Roffi M, Cikirikcioglu M, Ellenberger C, Licker MJ, Burri H, Noble S (2018) Conduction disorders using the Evolut R prosthesis compared with the CoreValve: has anything changed? Open Heart 5:e000770

    Article  Google Scholar 

  20. Pilgrim T, Stortecky S, Nietlispach F, Heg D, Tueller D, Toggweiler S, Ferrari E, Noble S, Maisano F, Jeger R, Roffi M, Grünenfelder J, Huber C, Wenaweser P, Windecker S (2016) Repositionable versus balloon-expandable devices for transcatheter aortic valve implantation in patients with aortic stenosis. J Am Heart Assoc 5:e004088

    Article  Google Scholar 

  21. Rodés-Cabau J, Urena M, Nombela-Franco L, Amat-Santos I, Kleiman N, Munoz-Garcia A, Atienza F, Serra V, Deyell MW, Veiga-Fernandez G, Masson JB, Canadas-Godoy V, Himbert D, Castrodeza J, Elizaga J, Francisco Pascual J, Webb JG, de la Torre JM, Asmarats L, Pelletier-Beaumont E, Philippon F (2018) Arrhythmic burden as determined by ambulatory continuous cardiac monitoring in patients with new-onset persistent left bundle branch block following transcatheter aortic valve replacement: The MARE study. JACC Cardiovasc Interv 11:1495–1505

    Article  Google Scholar 

  22. Rodríguez-Olivares R, van Gils L, El Faquir N, Rahhab Z, Di Martino LF, van Weenen S, de Vries J, Galema TW, Geleijnse ML, Budde RP, Boersma E, de Jaegere PP, Van Mieghem NM (2016) Importance of the left ventricular outflow tract in the need for pacemaker implantation after transcatheter aortic valve replacement. Int J Cardiol 216:9–15

    Article  Google Scholar 

  23. Rogers T, Steinvil A, Buchanan K, Alraies MC, Koifman E, Gai J, Torguson R, Okubagzi P, Ben-Dor I, Pichard A, Satler L, Waksman R (2017) Contemporary transcatheter aortic valve replacement with third-generation balloon-expandable versus self-expanding devices. J Interv Cardiol 30:356–361

    Article  Google Scholar 

  24. Schofer N, Deuschl F, Schön G, Seiffert M, Linder M, Schaefer A, Schirmer J, Lubos E, Reichenspurner H, Blankenberg S, Conradi L, Schäfer U (2018) Comparative analysis of balloon-versus mechanically-expandable transcatheter heart valves considering landing zone calcification. J Cardiol 71:540–546

    Article  Google Scholar 

  25. Schulz E, Jabs A, Gori T, von Bardeleben S, Hink U, Kasper-König W, Vahl CF, Münzel T (2016) Transcatheter aortic valve implantation with the new-generation Evolut R™: comparison with CoreValve® in a single center cohort. Int J Cardiol Heart Vasc 12:52–56

    PubMed  PubMed Central  Google Scholar 

  26. Seeger J, Gonska B, Rottbauer W, Wöhrle J (2017) Outcome with the repositionable and retrievable boston scientific lotus valve compared with the balloon-expandable Edwards Sapien 3 valve in patients undergoing transfemoral aortic valve replacement. Circ Cardiovasc Interv 10:10

    Article  Google Scholar 

  27. Sorajja P, Kodali S, Reardon MJ, Szeto WY, Chetcuti SJ, Hermiller J Jr, Chenoweth S, Adams DH, Popma JJ (2017) Outcomes for the commercial use of self-expanding prostheses in transcatheter aortic valve replacement: a report from the STS/ACC TVT registry. JACC Cardiovasc Interv 10:2090–2098

    Article  Google Scholar 

  28. Subban V, Murdoch D, Savage ML, Crowhurst J, Saireddy R, Poon KK, Incani A, Bett N, Burstow DJ, Scalia GM, Clarke A, Raffel OC, Aroney CN, Walters DL (2016) Outcomes of transcatheter aortic valve implantation in high surgical risk and inoperable patients with aortic stenosis: a single Australian Centre experience. Intern Med J 46:42–51

    Article  CAS  Google Scholar 

  29. van Gils L, Tchetche D, Lhermusier T, Abawi M, Dumonteil N, Rodriguez Olivares R, Molina-Martin de Nicolas J, Stella PR, Carrié D, De Jaegere PP, Van Mieghem NM (2017) Transcatheter heart valve selection and permanent pacemaker implantation in patients with pre-existent right bundle branch block. J Am Heart Assoc 6:e005028

    PubMed  PubMed Central  Google Scholar 

  30. Veulemans V, Sötemann DB, Kleinebrecht L, Keymel S, Jung C, Zeus T, Kelm M, Westenfeld R (2017) Transcatheter aortic valve implantation in high-risk/inoperable patients: repositionable versus non-repositionable self-expanding valve. J Heart Valve Dis 26:405–412

    PubMed  Google Scholar 

  31. Chaimani A, Higgins JP, Mavridis D, Spyridonos P, Salanti G (2013) Graphical tools for network meta-analysis in STATA. PLoS ONE 8:e76654

    Article  CAS  Google Scholar 

  32. Higgins JPT, Deeks JJ, Altman DG (eds) (2011) Chapter 16: Special topics in statistics. In: Higgins JPT, Green S (eds) Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 (updated March 2011). The Cochrane Collaboration. https://www.cochrane-handbook.org. Accessed 1 Nov 2018

  33. Athappan G, Gajulapalli RD, Tuzcu ME, Svensson LG, Kapadia SR (2016) A systematic review on the safety of second-generation transcatheter aortic valves. EuroIntervention 11:1034–1043

    Article  Google Scholar 

  34. Barbanti M, Buccheri S, Rodés-Cabau J, Gulino S, Généreux P, Pilato G, Dvir D, Picci A, Costa G, Tamburino C, Leon MB, Webb JG (2017) Transcatheter aortic valve replacement with new-generation devices: a systematic review and meta-analysis. Int J Cardiol 245:83–89

    Article  Google Scholar 

  35. van Rosendael PJ, Delgado V, Bax JJ (2018) Pacemaker implantation rate after transcatheter aortic valve implantation with early and new-generation devices: a systematic review. Eur Heart J 39:2003–2013

    Article  Google Scholar 

  36. Meredith IT, Hood KL, Haratani N, Allocco DJ, Dawkins KD (2012) Boston Scientific Lotus valve. EuroIntervention 8(Suppl Q):Q70–Q74

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Consortia

Corresponding author

Correspondence to Hisato Takagi.

Ethics declarations

Conflict of interest

None of the authors declare any potential conflict of interest.

Research involving human participants and/or animals

The present study is a meta-analysis of published articles, and neither a human nor animal study that should be approved by the appropriate ethics committee and performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki and its later amendments.

Informed consent

The present study is a meta-analysis of published articles, and accordingly, there are no persons who gave their informed consent prior to their inclusion in the study.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Electronic supplementary material

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Takagi, H., Hari, Y., Nakashima, K. et al. Network meta-analysis of new-generation valves for transcatheter aortic valve implantation. Heart Vessels 34, 1984–1992 (2019). https://doi.org/10.1007/s00380-019-01442-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00380-019-01442-w

Keywords

Navigation