Abstract
Percutaneous left atrial appendage (LAA) closure using the WATCHMAN device is a novel option for prevention of stroke associated with atrial fibrillation. However, device-related thrombus (DRT) formation is a concern after WATCHMAN implantation and the predictors of DRT still remain unclear. We aimed to clarify the predictors of DRT after WATCHMAN implantation by analyzing 78 patients (50 males, 72 ± 8 years, average CHA2DS2-VASc score of 4.3 + 1.8) who had undergone WATCHMAN implantation. WATCHMAN was successfully implanted in all patients and four (5%) developed DRT. Patients with DRT were more often female (75 vs. 34%, p = 0.094). CHA2DS2-VASc score was higher for patients with DRT (6.3 ± 2.5 vs. 4.2 ± 1.7, p = 0.022). Chronic kidney disease (100% vs. 43%, p = 0.024) and deep implantation of the device, which was defined as implant position below the LAA ostial plane (75 vs. 24%, p = 0.026), were more common in patients with DRT. HAS-BLED score (4.5 ± 1.0 vs. 3.5 ± 1.1, p = 0.074) was higher and oral anticoagulants (50 vs. 84%, p = 0.086) were less commonly prescribed for patients with DRT. Multivariable logistic regression analysis showed that higher CHA2DS2-VASc score (p = 0.022, OR 2.8) and deep implantation (p = 0.032, OR 24.7) were associated with DRT. These results suggest the possible role of CHA2S2-VASc scores and implantation depth in the development of DRT after percutaneous LAA closure using the WATCHMAN device.
Similar content being viewed by others
References
Fountain RB, Holmes DR, Chandrasekaran K, Packer D, Asirvatham S, Van Tassel R, Turi Z (2006) The PROTECT AF (WATCHMAN Left Atrial Appendage System for Embolic PROTECTion in Patients with Atrial Fibrillation) trial. Am Heart J 151:956–961
Holmes DR, Reddy VY, Turi ZG, Doshi SK, Sievert H, Buchbinder M, Mullin CM, Sick P (2009) Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomised non-inferiority trial. The Lancet 374:534–542
Reddy VY, Doshi SK, Sievert H, Buchbinder M, Neuzil P, Huber K, Halperin JL, Holmes D (2013) Percutaneous left atrial appendage closure for stroke prophylaxis in patients with atrial fibrillation: 2.3-Year Follow-up of the PROTECT AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients with Atrial Fibrillation) Trial. Circulation 127:720–729
Reddy VY, Sievert H, Halperin J, Doshi SK, Buchbinder M, Neuzil P, Huber K, Whisenant B, Kar S, Swarup V, Gordon N, Holmes D (2014) Percutaneous left atrial appendage closure vs warfarin for atrial fibrillation: a randomized clinical trial. JAMA 312:1988–1998
Reddy VY, Holmes D, Doshi SK, Neuzil P, Kar S (2011) Safety of percutaneous left atrial appendage closure: results from the Watchman Left Atrial Appendage System for Embolic Protection in Patients with AF (PROTECT AF) clinical trial and the Continued Access Registry. Circulation 123:417–424
Main ML, Fan D, Reddy VY, Holmes DR, Gordon NT, Coggins TR, House JA, Liao L, Rabineau D, Latus GG, Huber KC, Sievert H, Wright RF, Doshi SK, Douglas PS (2016) Assessment of Device-Related Thrombus and Associated Clinical Outcomes With the WATCHMAN Left Atrial Appendage Closure Device for Embolic Protection in Patients With Atrial Fibrillation (from the PROTECT-AF Trial). Am J Cardiol 117:1127–1134
Hahn RT, Abraham T, Adams MS, Bruce CJ, Glas KE, Lang RM, Reeves ST, Shanewise JS, Siu SC, Stewart W, Picard MH (2013) Guidelines for performing a comprehensive transesophageal echocardiographic examination: recommendations from the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists. J Am Soc Echocardiogr 26:921–964
Kitkungvan D, Nabi F, Ghosn MG, Dave AS, Quinones M, Zoghbi WA, Valderrabano M, Shah DJ (2016) Detection of LA and LAA Thrombus by CMR in Patients Referred for Pulmonary Vein Isolation. JACC Cardiovasc Imaging 9:809–818
Seward JB, Khandheria BK, Oh JK, Freeman WK, Tajik AJ (1992) Critical appraisal of transesophageal echocardiography: limitations, pitfalls, and complications. J Am Soc Echocardiogr 5:288–305
Castello R, Pearson AC, Fagan L, Labovitz AJ (1990) Spontaneous echocardiographic contrast in the descending aorta. Am Heart J 120:915–919
Levey AS, Bosch JP, Lewis JB, Greene T, Rogers N, Roth D (1999) A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Modification of diet in renal disease study group. Ann Intern Med 130:461–470
Kaneko H, Neuss M, Schau T, Weissenborn J, Butter C (2016) Impact of left ventricular systolic dysfunction on the outcomes of percutaneous edge-to-edge mitral valve repair using MitraClip. Heart Vessels 31:1988–1996
Miyamoto K, Aiba T, Arihiro S, Watanabe M, Kokubo Y, Ishibashi K, Hirose S, Wada M, Nakajima I, Okamura H, Noda T, Nagatsuka K, Noguchi T, Anzai T, Yasuda S, Ogawa H, Kamakura S, Shimizu W, Miyamoto Y, Toyoda K, Kusano K (2016) Impact of renal function deterioration on adverse events during anticoagulation therapy using non-vitamin K antagonist oral anticoagulants in patients with atrial fibrillation. Heart Vessels 31:1327–1336
Kondo T, Yamada T, Morita T, Furukawa Y, Tamaki S, Iwasaki Y, Kawasaki M, Kikuchi A, Kawai T, Takahashi S, Ishimi M, Hakui H, Ozaki T, Sato Y, Seo M, Sakata Y, Fukunami M (2016) The CHADS2 score predicts ischemic stroke in chronic heart failure patients without atrial fibrillation: comparison to other stroke risk scores. Heart Vessels. doi:10.1007/s00380-016-0861-7
Yamashita Y, Takagi D, Hamatani Y, Iguchi M, Masunaga N, Esato M, Chun YH, Itoh H, Nishimura M, Wada H, Hasegawa K, Ogawa H, Abe M, Akao M (2016) Clinical characteristics and outcomes of dialysis patients with atrial fibrillation: the Fushimi AF Registry. Heart Vessels 31:2025–2034
Kar S, Hou D, Jones R, Werner D, Swanson L, Tischler B, Stein K, Huibregtse B, Ladich E, Kutys R, Virmani R (2014) Impact of Watchman and Amplatzer devices on left atrial appendage adjacent structures and healing response in a canine model. JACC Cardiovasc Interv 7:801–809
Gasparini M, Ceriotti C, Bragato R (2012) Huge left atrial thrombus after left atrial appendage occlusion with a Watchman device. Eur Heart J 33:1998
Ketterer U, D’Ancona G, Siegel I, Ortak J, Ince H, Kische S (2016) Percutaneous left atrial appendage occlusion: Device thrombosis in clopidogrel non-responders. Int J Cardiol 204:196–197
Boersma LV, Schmidt B, Betts TR, Sievert H, Tamburino C, Teiger E, Pokushalov E, Kische S, Schmitz T, Stein KM, Bergmann MW (2016) Implant success and safety of left atrial appendage closure with the WATCHMAN device: peri-procedural outcomes from the EWOLUTION registry. Eur Heart J 37:2465–2474
Schneider B, Stollberger C, Sievers HH (2005) Surgical closure of the left atrial appendage—a beneficial procedure? Cardiology 104:127–132
Rosenzweig BP, Katz E, Kort S, Schloss M, Kronzon I (2001) Thromboembolus from a ligated left atrial appendage. J Am Soc Echocardiogr 14:396–398
Lam SC, Bertog S, Sievert H (2015) Incomplete left atrial appendage occlusion and thrombus formation after Watchman implantation treated with anticoagulation followed by further transcatheter closure with a second-generation Amplatzer Cardiac Plug (Amulet device). Catheter Cardiovasc Interv 85:321–327
Reddy VY, Mobius-Winkler S, Miller MA, Neuzil P, Schuler G, Wiebe J, Sick P, Sievert H (2013) Left atrial appendage closure with the Watchman device in patients with a contraindication for oral anticoagulation: the ASAP study (ASA Plavix Feasibility Study With Watchman Left Atrial Appendage Closure Technology). J Am Coll Cardiol 61:2551–2556
Beppu S, Nimura Y, Sakakibara H, Nagata S, Park YD, Izumi S (1985) Smoke-like echo in the left atrial cavity in mitral valve disease: its features and significance. J Am Coll Cardiol 6:744–749
Tsai LM, Chen JH, Fang CJ, Lin LJ, Kwan CM (1992) Clinical implications of left atrial spontaneous echo contrast in nonrheumatic atrial fibrillation. Am J Cardiol 70:327–331
Chimowitz MI, DeGeorgia MA, Poole RM, Hepner A, Armstrong WM (1993) Left atrial spontaneous echo contrast is highly associated with previous stroke in patients with atrial fibrillation or mitral stenosis. Stroke 24:1015–1019
Leung DY, Black IW, Cranney GB, Hopkins AP, Walsh WF (1994) Prognostic implications of left atrial spontaneous echo contrast in nonvalvular atrial fibrillation. J Am Coll Cardiol 24:755–762
Fatkin D, Kelly R, Feneley MP (1994) Left atrial appendage blood velocity and thromboembolic risk in patients with atrial fibrillation. J Am Coll Cardiol 24:1429–1430
Fatkin D, Kelly RP, Feneley MP (1994) Relations between left atrial appendage blood flow velocity, spontaneous echocardiographic contrast and thromboembolic risk in vivo. J Am Coll Cardiol 23:961–969
Acknowledgements
We thank all staff of the intervention laboratory in our institute.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors report no relationships that could be construed as a conflict of interest regarding this study.
Funding
This work was supported by the Japan Society for the Promotion of Science (Hidehiro Kaneko).
Additional information
Hidehiro Kaneko and Michael Neuss contributed equally to this publication (share first authorship).
Rights and permissions
About this article
Cite this article
Kaneko, H., Neuss, M., Weissenborn, J. et al. Predictors of thrombus formation after percutaneous left atrial appendage closure using the WATCHMAN device. Heart Vessels 32, 1137–1143 (2017). https://doi.org/10.1007/s00380-017-0971-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00380-017-0971-x