Skip to main content
Log in

Improvement of cold-wire response for measurement of temperature dissipation

  • Published:
Experiments in Fluids Aims and scope Submit manuscript

Abstract

This work aimed at improving fine-scale measurements using cold-wire anemometry. The dissipation ɛ θ of the temperature variance was measured on the axis of a heated turbulent round jet. The measurements were performed with a constant current anemometer (CCA) operating fine Pt–10%Rh wires at very low overheat. The CCA developed for this purpose allowed the use of the current injection method in order to estimate the time constant of the wire. In the first part of the paper, it is shown that the time constants obtained for two wire diameters −d=1.2 and d=0.58 μm – compare well with those measured at the same time using two other methods (laser excitation and pulsed wire). Moreover, for these two wires, the estimated time constants were in good agreement with those obtained from a semi-empirical relation. In the second part of the paper, a compensation procedure – post-processing filtering – was developed in order to improved the frequency response of the cold-wire probes. The measurements carried out on the axis of the jet (Re D =16 500, Re λ ≃ 167) showed that the frequency response of the 1.2 μm wire was significantly improved. In fact, the spectral characteristics of the compensated signal obtained with the 1.2 μm wire compared fairly well with those from the 0.58 μm wire. Moreover, the results indicated that the compensation procedure must be applied when the cut-off frequency of the cold-wire f c is lower than two times the Kolmogorov frequency f K. In the case where f c ≃ 0.6f K, the compensation procedure can reduce the error in the estimate of ɛ θ by more than 20%. When f c ≃ 2f K, the effect of the compensation is reduced to about 5%.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 3 November 2000/Accepted: 23 March 2001

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lemay, J., Benaïssa, A. Improvement of cold-wire response for measurement of temperature dissipation. Experiments in Fluids 31, 347–356 (2001). https://doi.org/10.1007/s003480100294

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s003480100294

Keywords

Navigation