Abstract
In this communication, the Digital Image Compression (DIC) – PIV system is introduced. The present system allows the measurement of mean and RMS velocities in turbulent flow fields, using JPEG digital image compression technique for on-line recording of thousands of images. The decompression and subsequent analysis of the images, performed by means of digital cross-correlation technique, is carried out off-line. Errors incurred by the application of the compression method are assessed and discussed. The effect of the compression is firstly analysed by linearly traversing (synthetic) computer-generated PIV-images at constant velocity. Secondly, accurate LDA measurements and data from direct numerical simulation (DNS) are used as a basis for the analysis in a low Reynolds number open water channel flow. The results show that excellent agreement between LDA and DIC–PIV measurements for mean and RMS velocities can be achieved using a compression factor up to 12.
Similar content being viewed by others
Author information
Authors and Affiliations
Additional information
Received: 27 August 1996 / Accepted: 15 December 1998
Rights and permissions
About this article
Cite this article
Freek, C., Sousa, J., Hentschel, W. et al. On the accuracy of a MJPEG-based digital image compression PIV-system. Experiments in Fluids 27, 310–320 (1999). https://doi.org/10.1007/s003480050355
Issue Date:
DOI: https://doi.org/10.1007/s003480050355