Abstract
Stepped spillways have higher energy dissipation than smoother hydraulic structures used to divert flood discharges. The inception point related to air entrainment is, however, located further upstream causing an undesired bulking of the flow depth. For large discharge rates and for straight stepped spillways, the skimming flow regime may be assumed two dimensional; this is an attractive feature for the application of non-intrusive flow visualization techniques because these methods measure the flow characteristics in the vicinity of the sidewalls which are likely to correlate with the flow at the centre of the flume. This paper tests the hypothesis that such techniques can be used to measure the flow inside the flume. The hypothesis is tested against measurements taken with an intrusive probe. Void fraction contour lines and velocity fields are obtained in 12 different stepped spillway configurations using the image processing procedure and the bubble image velocimetry, respectively. The void fraction and velocity results are overall consistent with the probe measurements. The velocity fields show a persistent underestimation of the probe measurements which can at least be partially explained by sidewall effects and possible probe’s overestimation.
This is a preview of subscription content, access via your institution.
















Notes
For BIV replace: Ptr2, smfUL and smfLL, by overlap (OV), SNR threshold (SNR) and of peak height filter (Peak).
\({\text{For BIV replace}}\left\{ {\begin{array}{*{20}c} {Ptr2 \mathop \to \limits_{dx = 20} \left[ {160:240} \right]} \\ {\begin{array}{*{20}c} {smfUl\mathop \to \limits_{dx = 20} \left[ {180:220} \right]} \\ {\begin{array}{*{20}c} {smfLL\mathop \to \limits_{dx = 20} \left[ {80:140} \right]} \\ \end{array} } \\ \end{array} } \\ \end{array} } \right.\) \({\text{by}}\left\{ {\begin{array}{*{20}c} {OL \mathop \to \limits_{dx = 0.25} \left[ {0.25:0.75} \right]} \\ {\begin{array}{*{20}c} {SNR\mathop \to \limits_{dx = 0.1} \left[ {1.1:1.5} \right]} \\ {\begin{array}{*{20}c} {Peak\mathop \to \limits_{dx = 0.1} \left[ {0.2:0.5} \right]} \\ \end{array} } \\ \end{array} } \\ \end{array} } \right..\)
Normalization is only done at the end with the maximum value obtained from all matrices. The normalization enables an easier cross-comparison between matrices.
For BIV replace: nf = (100, 400, 800, 1,200) and gr = (2, 4, 8, 16, 32) by nf = (50, 100, 200, 400, 800, 1,200) and interrogation window size iws = (12, 16, 24, 32, 40).
Abbreviations
- Dx:
-
Calibration step discretization
- C, Cp, Co:
-
Void fraction defined as the volume of air per unit volume (air concentration), void fraction measured using the IPP and the dual-tip conductivity probes
- Fr*:
-
Froude number related to step-induced macro-roughness
- g:
-
Acceleration due to gravity
- gr:
-
IPP grid resolution
- h90 :
-
Water depth for void fraction = 90 %
- i, j:
-
Matrix indexes
- iws:
-
BIV interrogation window size
- \(I_{Tn}^{{}}\) :
-
IPP nth threshold function
- lim S:
-
IPP water surface upper limit
- lim St:
-
IPP water surface lower limit
- lmf :
-
IPP fuzzy logic linear function
- np :
-
Number of points measured along the void fraction profile
- nf :
-
Number of frames (images)
- OL:
-
BIV overlap parameter
- Peak:
-
BIV peak height filter parameter
- px:
-
Pixel units
- \(PI_{i,j} ,\) \(PI_{{_{i,j} }}^{1 \ldots 4}\) :
-
IPP matrixes of pixel intensity
- \(PI_{i,j}^{f}\) :
-
IPP transformed matrix
- \(medPI_{i}\) :
-
IPP average pixel intensity per row of the \(PI_{i,j}\)
- \(vectPI_{i}\) :
-
IPP vector of the differences between every two \(medPI_{i}\) values distancing k rows apart
- Ptr1, Ptr2, Ptr3:
-
IPP threshold values
- Q:
-
Specific discharge
- SNR:
-
BIV threshold parameter for signal-to-noise ratio filter
- Smf :
-
IPP fuzzy logic S function
- S:
-
Step height
- S(c.c):
-
Calibration score
- tair :
-
Total duration time of air
- u, up, uo :
-
Flow velocity in chute direction, flow velocity measured using the BIV and the dual-tip conductivity probes,
- x, z:
-
Horizontal and vertical distances (related to the pseudo-bottom)
- x′, z′:
-
Horizontal and vertical distances (related to the step surfaces)
- ϕ:
-
Chute angle
- Δte :
-
Travelling time of detected air bubbles
- Δxe :
-
Distance in flow direction of the two electrodes
References
Amador A, Puertas J (2004) Characterization of the flow field in a stepped spillway by PIV. 12th International symposium on applications of laser techniques (1) 1–10
Bazaraa MS, Sherali HD, Shetty CM (1993) Nonlinear programming, 2nd edn. Wiley, New York
Boes RM (2000) Zweiphasenströmung und Energieumsetzung an Großkaskaden. PhD thesis, ETH Zürich
Bung DB (2011a) Developing flow in skimming flow regime on embankment stepped spillways. J Hydraul Res 49(5):639–648
Bung DB (2011b) Non-intrusive measuring of air–water flow properties in self-aerated stepped spillway flow. Proceedings of the 34th world congress of the international association for hydro- environment research and engineering: 33rd Hydrology and water resources symposium and 10th conference on hydraulics in water engineering
Bung DB (2013) Non-intrusive detection of air–water surface roughness in self-aerated chute flows. J Hydraul Res 51(3):332–329. doi:10.1080/00221686.2013.777373
Carvalho RF, Amador AT (2008) Flow field over a stepped spillway: physical and numerical approach. In: IAHR – symposium on hydraulic structures (IAHR), international symposium on hydraulic structures (IAHR), 20–24 Oct 2008, China
Chanson H (1993) Stepped spillway flows and air entrainment. Can J Civil Eng 20(3):422–435
Chanson H (2007) Bubbly flow structure in hydraulic jump. Eur J Mech - B/Fluids, 26(3):367–384
Chanson H, Felder S (2010) Turbulence measurements in air–water self-aerated flows: basic analysis and results. In: Curtis JS, Balachandar S (eds) 7th International conference on multiphase flow ICMF 2010. Tampa FL, USA, pp 1–11
Chanson H, Toombes L (2004) Hydraulics of stepped chutes: the transition flow L’ hydraulique des chutes en marches d’ escalier : l’ écoulement de transition. J Hydraul Eng 42(1):43–54
Felder S, Guenther P, Chanson H (2012) Air–water flow properties and energy dissipation on stepped spillways: a physical study of several pooled. The University of Queensland School of Civil Engineering, Queensland
Gonzalez CA (2005) An experimental study of free-surface aeration on embankment stepped chutes. PhD thesis, The University of Queensland, Queensland
Kimmoun O, Branger H (2007) A particle image velocimetry investigation on laboratory surf-zone breaking waves over a sloping beach. J Fluid Mec 588:353–397
Kramer K (2004) Mitteilungen development of aerated chute flow. PhD thesis ETH Zurich, Switzerland
Kucukali S, Chanson H (2008) Turbulence measurements in the bubbly flow region of hydraulic jumps. Exp Therm Fluid Sci 33(1):41–53
Leandro J, Carvalho R, Chachereau Y, Chanson H (2012) Estimating void fraction in a hydraulic jump by measurements of pixel intensity. Exp Fluids 52(5):1307–1318. doi:10.1007/s00348-011-1257-1
Lennon JM, Hill DF (2006) Particle image velocity measurements of undular and hydraulic jumps. J Hydraul Eng 132(12):1283–1294
Lin C, Hsieh S-C, Kuo K-J, Chang K-A (2008) Periodic oscillation caused by a flow over a vertical drop pool. J Hydraul Eng 134(7):948–960
Mossa M, Tolve U (1998) Flow visualization in bubbly two-phase hydraulic jump. J Fluid Eng 120:160–165
Murillo RE (2006) Experimental study of the development flow region on stepped chutes. PhD, University of Manitoba, Canada
Pfister M, Hager WH (2011) Self-entrainment of air on stepped spillways. Int J Multiph Flow 37(2):99–107
Rajaratnam N (1962) An experimental study of air entrainment characteristics of the hydraulic jump. J Inst Eng India 42:247–273
Resch F, Leutheusser H, Alemum S (1974) Bubbly two-phase flow in hydraulic jump. J Hydraul Div ASCE 100:137–149
Ryu Y, Chang K-A, Lim H-J (2005) Use of bubble image velocimetry for measurement of plunging wave impinging on structure and associated green water. Meas Sci Technol 16(10):1945–1953
Sveen JK (2004) An introduction to MatPIV v. 1.6.1. Center for Mathematical Sciences, Department of Applied Mathematics and Theoretical Physics, University of Cambridge
Thorwarth J (2008) Hydraulisches verhalten von treppengerinnen mit eingetieften stufen - selbstinduzierte abflussinstationaritäten und energiedissipation (Hydraulics of pooled stepped chutes: self induced unsteady flow and energy dissipation), in German. PhD, RWTH Aachen, Germany
Toombes L, Chanson H (2008) Flow patterns in nappe flow regime down low gradient stepped chutes Configurations des écoulements en nappe le long des déversoirs en gradins à pente faible. J Hydraul Res 46(1):4–14
Yasuda Y, Ohtsu I (1999) Flow resistance of skimming flow in stepped channels. Proceeding 28th IAHR congress, Graz, Austria, Session B14 (CD-ROM)
Acknowledgments
The first and third authors acknowledge the support of the Foundation for Science and Technology, the Operacional Temático Factores de Competitividade (COMPETE) program and the Fundo Europeu de Desenvolvimento Regional (FEDER) through project PTDC/AAC-AMB/101197/2008.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Leandro, J., Bung, D.B. & Carvalho, R. Measuring void fraction and velocity fields of a stepped spillway for skimming flow using non-intrusive methods. Exp Fluids 55, 1732 (2014). https://doi.org/10.1007/s00348-014-1732-6
Received:
Revised:
Accepted:
Published:
DOI: https://doi.org/10.1007/s00348-014-1732-6
Keywords
- Void Fraction
- Step Height
- Hydraulic Jump
- Step Edge
- Interrogation Window Size