Abstract
Planar self-calibration methods have become standard for stereo PIV to correct misalignments between laser light sheet and calibration plane. Computing cross-correlation between images from camera 1 and 2 taken at the same time, non-zero disparity vectors indicate rotational and translational misalignments relative to the coordinate system defined by a calibration plate. This approach works well for thin light sheets but fails for extended volumes recorded in 3D-PTV or tomographic PIV experiments. Here it is primarily necessary to correct calibration errors leading to triangulation errors in 3D-PTV or in degraded tomographic volume reconstruction. Tomographic PIV requires calibration accuracies of a fraction of a pixel throughout the complete volume, which is difficult to achieve experimentally. A new volumetric self-calibration technique has been developed based on the computation of the 3D position of matching particles by triangulation as in 3D-PTV. The residual triangulation error (‘disparity’) is then used to correct the mapping functions for all cameras. A statistical clustering method suitable for dense particle images has been implemented to find correct disparity map peaks from true particle matches. Disparity maps from multiple recordings are summed for better statistics. This self-calibration scheme has been validated using several tomographic PIV experiments improving the vector quality significantly. The relevance for other 3D velocimetry methods is discussed.
This is a preview of subscription content, access via your institution.








References
Brücker Ch (1996) 3-D scanning-particle-image-velocimetry: technique and application to a spherical cap wake flow. Exp Fluids 56:157–179
Calluaud D, David L (2004) Stereoscopic particle image velocimetry measurements of a flow around a surface-mounted block. Exp Fluids 36:33–61
Coudert S, Schon JP (2001) Back-projection algorithm with misalignment corrections for 2D3C stereoscopic PIV. Meas Sci Technol 12:1371–1381
Elsinga GE, Scarano F, Wieneke B, van Oudheusden BW (2006) Tomographic particle image velocimetry. Exp Fluids 41:933–947
Hartley R, Sturm P (1994) Triangulation. ARPA Image Understanding Workshop, Monterey, pp 957–966
Hori T, Sakakibara J (2004) High speed scanning stereoscopic PIV for 3D vorticity measurement in liquids. Meas Sci Technol 15:1067–1078
Maas HG (1996) Contributions of digital photogrammatry to 3D PTV. In: Dracos T (ed) Three-dimensional velocity and vorticity measuring and image annalysis techniques. Kluwer, Dordrecht, pp 191–208
Michaelis D, Poelma C, Scarano F, Westerweel J, Wieneke B (2006) A 3D time-resolved cylinder wake survey by Tomographic PIV. In: 12th international symposium on flow visualization, Göttingen, Germany, 10–14 September
Prasad A (2000) Stereoscopic particle image velocimetry. Exp Fluids 29:103–116
Scarano F, David L, Bsibsi M, Calluaud D (2005) S-PIV comparative assessment: image dewarping + misalignment correction and pinhole + geometric back projection. Exp Fluids 39:257–266
Soloff SM, Adrian RJ, Liu ZC (1997) Distortion compensation for generalized stereoscopic particle image velocimetry. Meas Sci Technol 8:1441–1454
Westerweel J, Scarano F (2005) A universal detection criterion for the median test. Exp Fluids 39–6, 1096
Wieneke B (2005) Stereo-PIV using self-calibration on particle images. Exp Fluids 39:267–280
Wieneke B, Taylor S (2006) Fat-sheet PIV with computation of full 3D-strain tensor using tomographic reconstruction. In: 13th international symposium on applications of laser techniques to fluid mechanics, Lisbon
Willert C (1997) Stereoscopic digital particle image velocimetry for application in wind tunnel flows. Meas Sci Technol 8:1465–1469
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Wieneke, B. Volume self-calibration for 3D particle image velocimetry. Exp Fluids 45, 549–556 (2008). https://doi.org/10.1007/s00348-008-0521-5
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00348-008-0521-5