Abstract
Introduction and objective
Fluoroscopy time influences radiation exposure of both surgeons and patients during endourological interventions. Changes in fluoroscopy habits of endourological surgeons after being informed about their fluoroscopy times were evaluated depending on their endourological experience.
Materials and methods
From April 2010 to April 2011, 402 endourological interventions in 337 Patients were assessed. Evaluated interventions were ureter stent placement (USP), ureter stent change (USC) nephrostomy change (NC), ureterorenoscopy (URS) and percutaneous nephrolithotomy (PCNL). Fluoroscopy time (FT) and operation time (OT) were recorded. For USP, USC and NC, the surgeons were divided into two groups: group I with >2 years of endourological experience and group II with <2 years experience. URS and PCNL only were performed by experienced surgeons. After 6 months, all surgeons were informed about their mean detected results. Both groups were compared, and changes in FT and OT in the second part of the study were analysed.
Results
Surgeons reduced their median fluoroscopy times up to 55 % after being informed about their fluoroscopy manners. Experienced surgeons reduced both operation and fluoroscopy times significantly for USP, USC and NC. For URS and PCNL, and OT and FT, the differences were not statistically significant. Inexperienced surgeons were not able to reduce both OT and FT significantly.
Conclusion
If experienced surgeons are informed about their fluoroscopy time during endourological interventions, fluoroscopy times can be reduced significantly in easy procedures, which leads to less radiation exposure of surgeons and patients. Inexperienced surgeons have less possibility to influence their fluoroscopy manners.
Similar content being viewed by others
References
The 2007 Recommendations of the International commission on radiological protection. ICRP publication 103. Ann ICRP 2007; 37(2–4):1–332
Bundesregierung Verordnung über den Schutz vor Schäden durch ionisierende Strahlen. Strahlenschutzverordnung-StrlSchV 2001
Radiation NAoSCotBEoI (2006) Health risks from exposure to low levels of ionizing radiation. BEIR VII PHASE 2 report, National Academies Press, Washington
Kumari G, Kumar P, Wadhwa P, Aron M, Gupta NP, Dogra PN (2006) Radiation exposure to the patient and operating room personnel during percutaneous nephrolithotomy. Int Urol Nephrol 38(2):207–210
Krupp N, Bowman R, Tenggardjaja C et al (2010) Fluoroscopic organ and tissue-specific radiation exposure by sex and body mass index during ureteroscopy. J Endourol 24(7):1067–1072
Mancini JG, Raymundo EM, Lipkin M et al (2010) Factors affecting patient radiation exposure during Percutaneous Nephrolithotomy. J Urol 184(6):2373–2377
Ritter M, Krombach P, Martinschek A et al (2012) Radiation exposure during endourologic procedures using over-the-table fluoroscopy sources. J Endourol 26(1):47–51
Ngo TC, Macleod LC, Rosenstein DI, Reese JH, Shinghal R (2011) Tracking intraoperative fluoroscopy utilization reduces radiation exposure during ureteroscopy. J Endourol 25(5):763–767
Botchu R, Ravikumar K (2008) Radiation exposure from fluoroscopy during fixation of hip fracture and fracture of ankle: effect of surgical experience. Indian j orthop 42(4):471–473
Darling S, Sammer M, Chapman T, Parisi MT (2011) Physician documentation of fluoroscopy time in voiding cystourethrography reports correlates with lower fluoroscopy times: a surrogate marker of patient radiation exposure. AJR Am J Roentgenol 196(6):W777–W780
Miller DL, Balter S, Cole PE et al (2003) Radiation doses in interventional radiology procedures: the RAD-IR study: part I: overall measures of dose. J Vasc Interv Radiol 14(6):711–727
Sheyn DD, Racadio JM, Ying J, Patel MN, Johnson ND (2008) Efficacy of a radiation safety education initiative in reducing radiation exposure in the pediatric IR suite. Pediatr Radiol 38(6):669–674
Vano E, Gonzalez L, Fernandez JM, Alfonso F, Macaya C (2006) Occupational radiation doses in interventional cardiology: a 15-year follow-up. Br J Radiol 79(941):383–388
Ferrandino MN, Bagrodia A, Pierre SA et al (2009) Radiation exposure in the acute and short-term management of urolithiasis at 2 academic centers. J Urol 181(2):668–672 (discussion 673)
Hellawell GO, Mutch SJ, Thevendran G, Wells E, Morgan RJ (2005) Radiation exposure and the urologist: what are the risks? J Urol 174(3):948–952 (discussion 952)
Lipkin ME, Wang AJ, Toncheva G, Ferrandino MN, Yoshizumi TT, Preminger GM (2012) Determination of patient radiation dose during ureteroscopic treatment of urolithiasis using a validated model. J Urol 187(3):920–924
Lowe FC, Auster M, Beck TJ, Chang R, Marshall FF (1986) Monitoring radiation exposure to medical personnel during percutaneous nephrolithotomy. Urology 28(3):221–226
Conflict of interest
No financial interests exist.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ritter, M., Siegel, F., Krombach, P. et al. Influence of surgeon’s experience on fluoroscopy time during endourological interventions. World J Urol 31, 183–187 (2013). https://doi.org/10.1007/s00345-012-0923-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00345-012-0923-0