Abstract
The optimum incident angle for a 4 mm long and 4 μm core thickness D-type optical fiber sensor in the intensity measurements is near at 89°. The sensitivity is higher than 40 (1/RIU) and its resolution is better than 2.5×10-5 RIU. This sensor is used to detect the refractive index or gas or liquid concentration in real-time, and it has some merits such as small, simple and inexpensive and provides an in vivo test.
Similar content being viewed by others
References
U. Kunz, A. Katerkamp, R. Renneberg, F. Spener, K. Cammann, Sens. Actuators B 32, 149 (1996)
A. Abdelghani, C. Veillas, J.M. Chovelon, N. Jaffrezic-Renault, H. Gagnaire, Synth. Met. 90, 193 (1997)
R. Slavik, J. Homola, E. Brynda, Biosens. Bioelectron. 17, 591 (2002)
M. Mitsushio, S. Higashi, M. Higo, Sens. Actuators A 111, 252 (2004)
E. Brynda, J. Homola, M. Houska, P. Pfeifer, J. Škvor, Sens. Actuators B 54, 132 (1999)
R. Slavik, J. Homola, J. Čtyroký, Sens. Actuators B 51, 311 (1998)
R. Slavik, J. Homola, J. Čtyroký, Sens. Actuators B 54, 74 (1999)
R. Slavik, J. Homola, J. Čtyroký, E. Brynda, Sens. Actuators B 74, 106 (2001)
M. Piliarik, J. Homola, Z. Maníková, J. Čtyroký, Sens. Actuators B 90, 236 (2003)
D. Monzón-Hernández, J. Villatoro, D. Talavera, D. Luna-Moreno, Appl. Opt. 43, 1216 (2004)
R.C. Jorgenson, Sens. Actuators B 73, 236 (2001)
E. Fontana, IEEE 50, 82 (2002)
W.B. Lin, N. Jaffrezic-Renault, A. Gagnaire, H. Gagnaire, Sens. Actuators 84, 198 (2000)
M. Iga, A. Seki, K. Watanabe, Sens. Actuators B 101, 368 (2004)
K. Kurihara, H. Ohkawa, Y. Iwasaki, O. Niwa, T. Tobita, K. Suzuki, Anal. Chim. Acta 523, 165 (2004)
S.F. Wang M.H. Chiu, R.S. Chang, Opt. Eng. Lett. 44, 030502-1 (2005)
M.H. Chiu, S.F. Wang, R.S. Chang, Opt. Lett. 30, 233 (2005)
B.D. Gupta, A.K. Sharma, Sens. Actuators B 107, 40 (2005)
J. Villatoro, A. García-Valenzuela, Appl. Opt. 38, 4837 (1999)
J. Homola, Sens. Actuators B 41, 207 (1997)
R. Naraoka, K. Kajikawa, Sens. Actuators B 107, 952 (2005)
K.H. Chen, C.C. Hsu, D.C. Su, Opt. Commun. 209, 167 (2002)
Author information
Authors and Affiliations
Corresponding author
Additional information
PACS
42.81.Pa; 07.07.Df; 73.20.Mf; 42.62.Eh; 07.60.Vg
Rights and permissions
About this article
Cite this article
Chiu, MH., Chi, MH. & Shih, CH. Optimum sensitivities of D-type optical fiber sensor at a specific incident angle. Appl. Phys. A 89, 413–416 (2007). https://doi.org/10.1007/s00339-007-4136-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00339-007-4136-0