Skip to main content

Advertisement

Log in

Triple-rule-out CT angiography using two axial scans with 16 cm wide-detector for radiation dose reduction

  • Chest
  • Published:
European Radiology Aims and scope Submit manuscript

    We’re sorry, something doesn't seem to be working properly.

    Please try refreshing the page. If that doesn't work, please contact support so we can address the problem.

Abstract

Objective

To explore the use of two consecutive axial scans in triple-rule-out (TRO) examination on a 16 cm wide-detector CT for radiation dose reduction.

Materials and methods

Sixty TRO patients were assigned to either study group (Group A, n = 30) or control group (Group B, n = 30). Group A used a two-phasic contrast injection: 25mgI/kg/s for 12 s in 1st and at 3.0 ml/s injection rate for 7 s in 2nd phase. The pulmonary artery, coronary artery and aorta were scanned in succession with two axial scans using smart-coverage technique. Group B used the conventional protocol of scanning pulmonary arteries first in helical, followed by coronary arteries in axial and aorta in helical mode with contrast injection of 25mgI/kg/s for 14 s. All images were reconstructed with 80% ASIR-V. The qualitative and quantitative image assessment and effective dose of the two groups were statistically compared.

Results

The demographic data and quantitative measurements and qualitative image scores between the two groups were statistically the same (p > 0.05). However, Group A reduced radiation dose by 52% (2.67 ± 0.98 mSv vs. 5.65 ± 1.37 mSv) (p < 0.001).

Conclusion

Using two consecutive axial scans in triple-rule-out on a 16 cm wide-detector CT reduces radiation dose while maintaining image quality compared with the conventional TRO protocol.

Key Points

• Triple-rule-out can be performed with two-axial scans on a wide-detector CT system.

• TRO with two-axial scans maintain image quality compared with conventional protocol.

• TRO with two-axial scans reduces 52% radiation dose over conventional protocol.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

Explore related subjects

Discover the latest articles, news and stories from top researchers in related subjects.

Abbreviations

ACS:

Acute coronary syndrome

AD:

Aortic dissection

ASIR:

Adaptive statistical iterative reconstruction

CNR:

Contrast-to-noise ratio

CTA:

Computed tomography angiography

CTDI:

CT dose index

DFOV:

Display field of view

DLP:

Dose-length product

MIP:

Maximum intensity projection

mSv:

Millisievert

PTE:

Pulmonary thromboembolism

ROI:

Region-of-interest

SD:

Standard deviation

SSF:

Snapshot freeze

TRO:

Triple-rule-out

VR:

Volume rendering

References

  1. Wnorowski AM, Halpern EJ (2016) Diagnostic yield of triple-rule-out CT in an emergency setting. AJR Am J Roentgenol 207(2):295–301

    Article  Google Scholar 

  2. Kim HS, Kim SM, Cha MJ et al (2017) Triple rule-out CT angiography protocol with restricting field of view for detection of pulmonary thromboembolism and aortic dissection in emergency department patients: simulation of modified CT protocol for reducing radiation dose. Acta Radiol 58(5):521–527

    Article  Google Scholar 

  3. Manheimer ED, Peters MR, Wolff SD et al (2011) Comparison of radiation dose and image quality of triple-rule-out computed tomography angiography between conventional helical scanning and a strategy incorporating sequential scanning. Am J Cardiol 107(7):1093–1098

    Article  Google Scholar 

  4. Ayaram D, Bellolio MF, Murad MH et al (2013) Triple rule-out computed tomographic angiography for chest pain: a diagnostic systematic review and meta-analysis. Acad Emerg Med 20(9):861–871

    Article  Google Scholar 

  5. Krissak R, Henzler T, Prechel A et al (2012) Triple-rule-out dual-source CT angiography of patients with acute chest pain: dose reduction potential of 100 kV scanning. Eur J Radiol 81(12):3691–3696

    Article  Google Scholar 

  6. Mayo JR, Aldrich J, Muller NL et al (2003) Radiation exposure at chest CT: a statement of the Fleischner society. Radiology 228(1):15–21

    Article  Google Scholar 

  7. Andreini D, Pontone G, Mushtaq S et al (2017) Image quality and radiation dose of coronary CT angiography performed with whole-heart coverage CT scanner with intra-cycle motion correction algorithm in patients with atrial fibrillation. Eur Radiol. https://doi.org/10.1007/s00330-017-5131-2

    Article  Google Scholar 

  8. Wong DTL, Soh SY, Ko BS et al (2014) Superior CT coronary angiography image quality at lower radiation exposure with second generation 320-detector row CT in patients with elevated heart rate: a comparison with first generation 320-detector row CT. Cardiovasc Diagn Ther 4(4):299–306

    PubMed  PubMed Central  Google Scholar 

  9. Hong C, Becker CR, Huber A et al (2001) ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 220(3):712–717

    Article  CAS  Google Scholar 

  10. European guideline on quality criteria for computed tomography (1999) Brussels, Belgium Report EUR 16262 EN

  11. Frauenfelder T, Appenzeller P, Karlo C et al (2009) Triple rule-out CT in the emergency department: protocols and spectrum of imaging findings. Eur Radiol 19:789–799

    Article  Google Scholar 

  12. Messerli M, Dewes P, Scholtz J et al (2017) Evaluation of an adaptive detector collimation for prospectively ECG-triggered coronary CT angiography with third-generation dual-source CT. Eur Radiol. https://doi.org/10.1007/s00330-017-5177-1

    Article  Google Scholar 

  13. Hou DJ, Tso DK, Davison C et al (2013) Clinical utility of ultra high pitch dual source thoracic CT imaging of acute pulmonary embolism in the emergency department: are we one step closer towards a non-gated triple rule out? Eur J Radiol 82(10):1793–1798

    Article  Google Scholar 

  14. Sommer WH, Schenzle JC, Becker CR et al (2009) Saving dose in triple-rule-out computed tomography examination using a high-pitch dual spiral technique. Invest Radiol 45:64–71

    Article  Google Scholar 

  15. Halpern EJ, Levin DC, Zhang S et al (2009) Comparison of image quality and arterial enhancement with a dedicated coronary CTA protocol versus a triple rule-out coronary CTA protocol. Acad Radiol 16(9):1039–1048

    Article  Google Scholar 

  16. Burris AC, Boura JA, Raff GL (2015) Triple rule out versus coronary CT angiography in patients with acute chest pain: results from the ACIC consortium. J Am Coll Cardiol Img 8(7):817–825

    Article  Google Scholar 

  17. Takx RAP, Krissak R, Fink C et al (2017) Low-tube-voltage selection for triple-rule-out CTA: relation to patient size. Eur Radiol 27(6):1–6

    Article  Google Scholar 

Download references

Funding

The authors state that this work has not received any funding.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Taiping He.

Ethics declarations

Guarantor

The scientific guarantor of this publication is Taiping He.

Conflict of interest

The authors of this manuscript declare no conflict of interest exits in the submission of this manuscript.

Statistics and biometry

No complex statistical methods were necessary for this paper.

Informed consent

Written informed consent was obtained from all subjects (patients) in this study.

Ethical approval

Institutional Review Board approval was obtained.

Methodology

• Prospective

• randomized controlled trial

• performed at one institution

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chen, Y., Wang, Q., Li, J. et al. Triple-rule-out CT angiography using two axial scans with 16 cm wide-detector for radiation dose reduction. Eur Radiol 28, 4654–4661 (2018). https://doi.org/10.1007/s00330-018-5426-y

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00330-018-5426-y

Keywords

Navigation