Abstract
Objective
Iterative reconstruction (IR) allows diagnostic CT imaging with less radiation exposure than filtered back projection (FBP). We studied an IR low-dose CT abdomen/pelvis (LDCTAP) protocol, designed to image at an effective dose (ED) approximating 1 mSv in patients with Crohn’s disease (CD).
Methods
Forty patients, mean age 37 ± 13.4 years (range 17–69), with CD underwent two synchronous CT protocols (conventional-dose (CDCTAP) and LDCTAP). CDCTAP and LDCTAP images were compared for diagnostic acceptability, yield, image quality and ED (in millisieverts). The optimal level of IR for LDCTAP was also studied.
Results
LDCTAP yielded a mean ED of 1.3 ± 0.8 mSv compared with 4.7 ± 2.9 mSv for CDCTAP, reducing ED by 73.7 ± 3.3 % (mean dose reduction, 3.5 ± 2.1 mSv; P < 0.001) and dose length product by 73.6 ± 2.6 % (P < 0.001). Sub-millisievert (0.84 mSv) imaging was performed for patients with a body mass index (BMI) less than 25 (i.e. 63 % of our cohort). LDCTAP resulted in increased image noise and reduced diagnostic acceptability compared with CDCTAP despite use of IR, but detection of extra-luminal complications was comparable.
Conclusion
Patients with suspected active CD can be adequately imaged using LDCTAP, yielding comparable information regarding extent, activity and complications of CD compared with CDCTAP, but with 74 % less dose. LDCTAP at doses equivalent to that of two abdominal radiographs represents a feasible alternative to CDCTAP.
Key points
• Radiation dose is a concern when imaging patients with Crohn’s disease.
• New techniques allow low-dose abdominopelvic CT with acceptable image quality.
• Using hybrid iterative reconstruction, its diagnostic yield compares well with that of conventional CT.
• Sub-millisievert CT of patients with Crohn’s disease appears technically and clinically feasible.
Similar content being viewed by others
References
Huprick JE, Rosen MP, Fidler JL et al (2010) ACR appropriateness criteria on Crohn’s disease. J Am Coll Radiol 7:94–102
Schreyer SG, Seitz J, Feuerbach S et al (2004) Modern imaging using computer tomography and magnetic resonance imaging for inflammatory bowel disease (IBD). Inflamm Bowel Dis 10:45–54
Desmond AN, O’ Regan K, Curran C et al (2008) Crohn’s disease: factors associated with exposure to high levels of diagnostic radiation. Gut 57:1524–9
Cardis E, Vrijheid M, Blettner M et al (2007) The 15-country collaborative study of cancer risk among radiation workers in the nuclear industry: estimates of radiation-related cancer risks. Radiat Res 167:396–416
Mettler FA Jr, Huda W, Yoshizumi TT et al (2008) Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 248:254–63
Leyendecker JR, Bloomfeld RS, DiSantis DJ et al (2009) MR enterography in the management of patients with Crohn disease. Radiographics 29:1827–46
Fidler JL, Guimaraes L, Einstein DM (2009) MR imaging of the small bowel. Radiographics 29:1811–25
Prassopoulos P, Papanikolaou N, Grammatikakis J et al (2001) MR enteroclysis imaging of Crohn disease. Radiographics 21 Spec No:S161–72
Van Assche G, Dignass A, Panes J et al (2010) The second European evidence-based consensus on the diagnosis and management of Crohn’s disease: definitions and diagnosis. J Crohns Colitis 4:7–27
McCollough CH, Primak AN, Braun N et al (2009) Strategies for reducing radiation dose in CT. Radiol Clin North Am 194:191–9
Fleischmann D, Boas FE (2011) Computed tomography – old ideas and new technology. Eur Radiol 21:510–7
Silva AC, Lawder HJ, Hara A (2010) Innovations in CT dose reduction strategy: application of adaptive statistical iterative reconstruction algorithm. AJR AM J Roentgenol 194:191–9
Desai GS, Uppot RN, Yu EW et al (2012) Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults. Eur Radiol 22:1631–40
Mitsumori LM, Shuman WP, Busey JM et al (2012) Adaptive statistical iterative reconstruction versus filtered back projection in the same patient: 64 channel liver CT image quality and patient radiation dose. Eur Radiol 22:138–43
Winklehner A, Karlo C, Puippe G et al (2011) Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential. Eur Radiol 21:2521–6
Desmond AN, O’Regan K, Malik N et al (2012) Selection of symptomatic patients with Crohn’s disease for abdominopelvic computed tomography: role of serum C-reactive protein. Can Assoc Radiol J 63:267–74
Bongartz G, Golding SJ, Jurik AG et al (2000) European guidelines on quality criteria for computed tomography, EUR 16262. The European Commission’s Study Group on Development of Quality Criteria for Computed Tomography. Office for Official Publications of the European Communities, Luxembourg
Bongartz G, Golding SJ, Jurik AG et al (2004) 2004 CT quality criteria. Office for Official Publications of the European Communities, Luxembourg
Prakash P, Kalra MK, Kambadakone AK et al (2010) Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique. Invest Radiol 45:202–10
Singh S, Kalra MK, Hsieh J et al (2010) Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques. Radiology 257:373–83
Kalra MK, Rizzo S, Maher MM et al (2005) Chest CT performed with z-axis modulation: scanning protocol and radiation dose. Radiology 237:303–8
Kalra MK, Maher MM, Kamath RS et al (2004) 16-slice multidetector-row CT of the abdomen and pelvis: a study for optimization of z-axis modulation technique in 153 subjects. Radiology 233:241–249
Kalra MK, Maher MM, Toth TL et al (2004) Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis. Radiology 232:347–53
Marin D, Nelson RC, Schindera ST et al (2010) Low-tube voltage, high tube current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm – initial clinical experience. Radiology 254:145–53
Nakayama Y, Awai K, Funama Y et al (2006) Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography. AJR Am J Roentgenol 187:W490–7
Jackson VP, Cushing T, Abujudeh HH et al (2009) RADPEER scoring white paper. J Am Coll Radiol 6:21–5
Brenner DJ, Hall EJ (2007) Computed tomography – an increasing source of radiation exposure. N Engl J Med 357:2277–84
Kinsella SM, Coyle JP, Long EB et al (2010) Maintenance haemodialysis patients have high cumulative radiation exposure. Kidney Int 78:789–93
O’Connell OJ, McWilliams S, McGarrigle A et al (2012) Radiologic imaging in cystic fibrosis: cumulative effective dose and changing trends over 2 decades. Chest 141:1575–83
O’Regan K, O’Connor OJ, O’Neill SB et al (2012) Plain abdominal radiographs in patients with Crohn’s disease: radiological findings and diagnostic value. Clin Radiol 67:774–81
Flicek KT, Hara AK, Silva AC et al (2010) Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study. AJR Am J Roentgenol 195:126–31
Hara AK, Paden RG, Silva AC et al (2009) Iterative reconstruction techniques for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 193:764–71
May MS, Wust W, Brand M et al (2011) Dose reduction in abdominal computed tomography: intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dual-source computed tomography. Invest Radiol 46:465–70
Sagara Y, Hara AK, Pavlicek W et al (2010) Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients. AJR Am J Roentgenol 195:713–9
Schindera ST, Nelson RC, DeLong DM et al (2007) Multi-detector row CT of the small bowel: peak enhancement temporal window—initial experience. Radiology 243:438–44
Acknowledgements
Jackie Bye is an employee of GE Healthcare.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
O’Neill, S.B., Mc Laughlin, P.D., Crush, L. et al. A prospective feasibility study of sub-millisievert abdominopelvic CT using iterative reconstruction in Crohn’s disease. Eur Radiol 23, 2503–2512 (2013). https://doi.org/10.1007/s00330-013-2858-2
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00330-013-2858-2