Abstract
The aim of the study was to assess the clinical value of combined SPECT/CT imaging using L-3-[123I]iodine-α-methyl tyrosine (IMT) for the differential diagnosis of recurrences in patients pre-treated for head and neck cancer. Thirty-four consecutive patients with biopsy-proven carcinomas, who had previously been treated by surgery and/or radio/chemotherapy, were examined at our clinic by IMT-SPECT using a dual-head system with integrated low-dose CT. SPECT results were correlated with histopathology, clinical and CT/MRI follow-up data. In the follow-up after SPECT examination, the final diagnosis of recurrent tumour was established in 26 patients; the remaining eight patients were recurrence-free (follow-up >6 months). IMT-SPECT/CT correctly detected recurrent disease and/or neck lymph node metastases in 22 patients. In addition, distant metastases were displayed in two patients. The study was false-negative in four patients (sensitivity 85%). True-negative results were registered in seven patients, and false-positive in one patient. Image fusion with coregistered low-dose CT facilitates the localisation and interpretation of IMT-SPECT findings. IMT-SPECT using integrated low-dose CT is a promising non-invasive imaging tool for the detection of head and neck cancer recurrences and their differentiation from treatment-induced changes.
Similar content being viewed by others
References
Myers E, Leffall L (1991) Head and neck oncology: diagnosis, treatment and rehabilitation. Little Brown, Boston
Bronstein AD, Nyberg DA, Schrarzt AN, Shuman WP, Griffin BR (1989) Soft-tissue changes after head and neck radiation: CT findings. Am J Neuroradiol 10:171–175
Som PM (1992) Detection of metastasis in cervical lymph nodes: CT and MR citeria and differential diagnosis. Am J Roentgenol 158:961–969
Chisin R (1999) Nuclear medicine in head and neck oncology: reality and perspectives. J Nucl Med 40:91–95
Davis JP, Maisey NM, Chevreton EB (1998) Positron emission tomography: a useful imaging technique for otolaryngology, head and neck surgery? J Laryngol Otol 112:125–127
Baum U, Anders K, Steinbichler G, Lell M, Greess H, Riedel T, Kachelriess M, Kalender WA, Bautz WA (2004) Improvement of image quality of multislice spiral CT scans of the head and neck region using a raw data-based multidimensional adaptive filtering (MAF) technique. Eur Radiol 14:1873–1881
Lapela M, Grenman R, Kurki T, Joensuu H, Leskinen S, Lindholm P, Haaparanta M, Ruotsalainen U, Minn H (1995) Head and neck cancer: detection of recurrence with PET and 2-[F-18]fluoro-2-deoxy-D-glucose. Radiology 197:205–211
Farber LA, Benard F, Machtay M, Smith RJ, Weber RS, Weinstein GS, Chalian AA, Alavi A, Rosenthal DI (1999) Detection of recurrent head and neck squamous cell carcinomas after radiation therapy with 2-18F-fluoro-2-deoxy-D-glucose positron emission tomography. Laryngoscope 109:970–975
Fischbein NJ, AAssar OS, Caputo GR, Kaplan MJ, Singer MI, Price DC, Dillon WP, Hawkins RA (1998) Clinical utility of positron emission tomography with 18F-fluorodeoxyglucose in detecting residual/recurrent squamous cell carcinoma of the head and neck. Am J Neuroradiol 19:1189–1196
Kao CH, ChangLai SP, Chieng PU, Yen RF, Yen TC (1998) Detection of recurrent or persistent nasopharyngeal carcinomas after radiotherapy with 18-fluoro-2-deoxyglucose positron emission tomography and comparison with computed tomography. J Clin Oncol 16:3550–3555
Wong RJ, Lin DT, Schoder H, Patel SG, Gonen M, Wolden S, Pfister DG, Shah JP, Larson SM, Kraus DH (2002) Diagnostic and prognostic value of [(18)F]fluorodeoxyglucose positron emission tomography for recurrent head and neck squamous cell carcinoma. J Clin Oncol 20:4199–4208
Yamada S, Kubota K, Kubota R, Ido T, Tamashashi N (1995) High accumulation of fluorine-fluorodeoxyglucose in terpentine-induced inflammatory tissue. J Nucl Med 36:1301–1306
Reinhardt MJ, Kubota K, Yamada S, Iwata R, Yaegashi H (1997) Assessment of cancer recurrence in residual tumors after fractionated radiotherapy: a comparison of flouorodeoxyglucose, L-methionine and thymidine. J Nucl Med 38:280–287
Hautzel H, Müller-Gärtner HW (1997) Early changes in fluorine-18-FDG uptake during radiotherapy. J Nucl Med 38:1384–1386
Leskinen-Kallio S, Nagren K, Lehikoinen P, Ruotsalainen U, Teras M, Joensuu H (1992) Carbon-11-methionine and PET is an effective method to image head and neck cancer. J Nucl Med 33:691–695
Lindholm P, Leskinen-Kallio S, Grenman R, Lehikoinen P, Nagren K, Teras M, Ruotsalainen U, Joensuu H (1995) Evaluation of response to therapy in head and neck cancer by positron emission tomography and [11C]methionine. Int J Radiat Oncol Biol Phys 32:787–794
Nuutinen J, Jyrkkio S, Lehikoinen P, Lindholm P, Minn H (1999) Evaluation of early response to radiotherapy in head and neck cancer measured with [11C]methionine-positron emission tomography. Radiother Oncol 52:225–232
Chesnay E, Babin E, Constans JM, Agostini D, Bequignon A, Regeasse A, Sobrio F, Moreau S (2003) Early response to chemotherapy in hypophyryngeal cancer: assessment with (11)C-methionine PET. Correlation with morphologic response, and clinical outcome. J Nucl Med 44:526–532
Langen KJ, Coenen HH, Roosen N, Kling P, Muzik O, Herzog H, Kuwert T, Stöcklin G, Feinendegen LE (1990) SPECT studies of brain tumors with L-3-[123]iodo-a-methyltyrosine: comparison with PET, 124IMT and first clinical results. J Nucl Med 31:281–286
Langen KJ, Ziemons K, Kiwit JCW, Herzog H, Kuwert T, Bock WJ, Stöcklin G, Feinendegen LE, Müller-Gärtner HW (1997) 3-[123I]iodo-alpha-methyltyrosine and [methyl-11C]-L-methionine uptake in cerebral gliomas: a comparative study using SPECT and PET. J Nucl Med 38:517–522
Langen K-J, Pauleit D, Coenen HH (2002) 3-(123I)-Iodo-a-methyl-L-tyrosne: uptake mechanisms and clinical applications. Nucl Med Biol 29:625–631
Dierickx LO, Everaert H, Deron P, Voordeckers M, Lahoutte T, Bossuyt A (2003) Evaluation of the response to therapy of head and neck squamous cell carcinoma by using 3-[123I]iodo-L-alpha-methyl tyrosine and single photon emission tomography. Nucl Med Commun 24:633–641
Flamen P, Bernheim N, Deron P, Caveliers V, Chavatte K, Franken PR, Bossuyt A (1998) Iodine-123 alpha-methyl-l-tyrosine single-photon emission tomography for the visualization of head and neck squamous cell carcinomas. Eur J Nucl Med 25:177–181
Dierickx LO, Lahoutte T, Deron P, Caveliers V, Vanhove C, Everaert H, Bossuyt A (2001) Diagnosis of recurrent head and neck squamous cell carcinoma with 3-[123I]iodo-L-alpha-methyltyrosine SPET. Eur J Nucl Med 28:282–287
Tomura N, Watanabe O, Omachi K, Sakuma I, Takahashi S, Otani T, Kidani H, Watarai J (2004) Image fusion of thallium-201 SPECT and MR imaging for the assessment of recurrent head and neck tumors following flap reconstructive surgery. Eur Radiol 14:1249–1254
Krummreich C, Holsbach M, Stöcklin G (1994) Direkt electrophilic radioiodination of tyrosine analogues: their in-vivo stability and brain uptake in mice. Appl Radiat Isotopes 45:929–935
Biersack HJ, Coenen HH, Stocklin G, Reichmann K, Bockisch A, Oehr P, Kashab M, Rollmann O (1989) Imaging of brain tumors with L-3-[123I]iodo-α-methyl tyrosine and SPECT. J Nucl Med 30:110–112
Samnick S, Bader JB, Hellwig D, Moringlane JR, Alexander C, Romeike BF, Feiden W, Kirsch CM (2002) Clinical value of iodine-123-alpha-methyl-L-tyrosine single-photon emission tomography in the differential diagnosis or recurrent brain tumor in patients pretreated for glioma at follow-up. J Clin Oncol 15:396–404
Kuwert T, Woesler B, Morgenroth C, Lerch H, Schafers M, Palkovic S, Matheja P, Brandau W, Wassmann H, Schober O (1998) Diagnosis of recurrent glioma with SPECT and iodine-123-alpha-methyl tyrosine. J Nucl Med 39:23–27
Matheja P, Weckesser M, Rickert C, Franzius C, Palkovic S, Riemann B, Schober O (2002) I-123-lodo-alpha-methyl tyrosine SPECT in non-parenchymal brain tumours. Nuklearmediziner 41:191–196
Plotkin M, Eisenacher J, Bruhn H, Wurm R, Michel R, Stockhammer R, Feußner A, Dudeck O, Wust P, Felix R, Amthauer H (2004) 123I-IMT SPECT and 1H MR-spectroscopy at 3.0 Tesla in the differential diagnosis of recurrent or residual gliomas: a comparative study. J Neuro-oncol 70:49–58
Plotkin M, Amthauer H, Eisenacher J, Wurm R, Michel R, Wust R, Stockhammer F, Gutberlet M, Röttgen R, Ruf J, Felix R (2005) Value of 123I-IMT SPECT for diagnosis of recurrent non-astrocytic intracranial tumours. Neuroradiology 47:18–26
Pauleit D, Floeth F, Tellmann L, Hamacher H, Hautzel H, Müller HW, Coenen HH, Langen KJ (2004) Comparison of O-(2-18F-fluoroethyl)-L-tyrosinePET and 3-123I-iodo-α-methyl-L-tyrosine SPECT in brain tumors. J Nucl Med 45:374–381
Jager PL, Franssen EJ, Kool W, Szabo BG, Hoekstra HJ, Groen HJ, de Vries EG, van Imhoff GW, Vaalburg W, Piers DA (1998) Feasibility of tumor imaging using L-3-[iodine-123]-iodo-alpha-methyl-tyrosine in extracranial tumors. J Nucl Med 39:1736–1743
Jager PL, Groen HJ, van der Leest A, van Putten JW, Pieterman RM, de Vries EG, Piers DA (2001) L-3-[123I]iodo-alpha-methyl-tyrosine SPECT in non-small cell lung cancer: preliminary observations. J Nucl Med 42:579–585
Willkomm P, Bangard M, Guhlke S, Sartor J, Bender H, Gallkowski U, Reichmann K, Biersack HJ (2002) Comparison of [18F]FDG-PET and L-3[123I]-iodo-alpha-methyl tyrosine (I-123 IMT)-SPECT in primary lung cancer. Ann Nucl Med 16:503–506
Jager PL, Plaat BE, de Vries EG, Molenaar WM, Vaalburg W, Piers DA, Hoekstra HJ (2000) Imaging of soft-tissue tumors using L-3-[iodine-123]iodo-alpha-methyl-tyrosine single photon emission computed tomography: comparison with proliferative and mitotic activity, cellularity, and vascularity. Clin Cancer Res 6:2252–2259
Jager PL, Meijer WG, Kema IP, Willemse PH, Piers DA, de Vries EG (2000) L-3-[123I]Iodo-alpha-methyltyrosine scintigraphy in carcinoid tumors: correlation with biochemical activity and comparison with [111In-DTPA-D-Phe1]-octreotide imaging. J Nucl Med 41:1793–1800
Steinert H, Boni R, Huch-Boni RA, Capaul R, von Schulthess GK, Westera G (1997) [123I]-alpha-methyltyrosine scintigraphy in malignant melanoma. Nuklearmediziner 36:36–41
Henze M, Mohammed A, Mier W, Rudat V, Dietz A, Nollert J, Eisenhut M, Haberkorn U (2002) Pretreatment evaluation of carcinomas of the hypopharynx and larynx with 18F-fluorodeoxyglucose, 123I-alpha-methyl-L-tyrosine and 99mTc-hexakis-2-methoxyisobutylisonitrile. Eur J Nucl Med Mol Imaging 29:324–330
Ruf J, Lehmkuhl L, Bertram H, Sandrock D, Amthauer H, Humplik B, Munz DL, Felix R (2004) Impact of SPECT and integrated low-dose CT after radioiodine therapy on the management of patients with thyroid carcinoma. Nucl Med Commun 25:1177–1182
Pfannenberg AC, Eschmann SM, Horger M, Lamberts R, Vonthein R, Claussen CD, Bares R (2003) Benefit of anatomical-functional image fusion in the diagnostic work-up of neuroendocrine neoplasms. Eur J Nucl Med Mol Imaging 30:835–843
Kaczirek K, Prager G, Kienast O, Dobrozemsky G, Dudczak R, Niederle B, Kurtaran A (2003) Combined transmission and (99m)Tc-sestamibi emission tomography for localization of mediastinal parathyroid glands. Nuklearmediziner 42:220–223
Ozer S, Dobrozemsky G, Kienast O, Beheshti M, Becherer A, Niederle B, Kainberger F, Dudczak R, Kurtaran A (2004) Value of combined XCT/SPECT technology for avoiding false positive planar (123)I-MIBG scintigraphy. Nuklearmediziner 43:164–170
Schwartz LH, Ozsahin M, Zhang GN, Touboul E, De Vataire F, Andolenko P, Lacau-Saint-Guily J, Laugier A, Schlienger M (1994) Synchronous and metachronous head and neck carcinomas. Cancer 74:1933–1938
Acknowledgements
Results of this study were partly presented at the 50th annual meeting of the Society of Nuclear Medicine in New Orleans (USA) in June 2003 and at the annual meeting of the European Association of Nuclear Medicine in Helsinki (Finland) in September 2004. The authors thank Gisela Keller for her assistance in preparing this study. Furthermore, the authors are very grateful to Professor Dr. Karl-Joseph Langen (Institute of Medicine, Research Centre Jülich) for valuable advises on data analysis.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Plotkin, M., Wurm, R., Eisenacher, J. et al. Combined SPECT/CT imaging using 123I-IMT in the detection of recurrent or persistent head and neck cancer. Eur Radiol 16, 503–511 (2006). https://doi.org/10.1007/s00330-005-2832-8
Received:
Revised:
Accepted:
Published:
Issue Date: