Abstract
Airborne transmission is an important route for many microbial pathogens in outdoor and indoor environments, including hospitals. A 2-year-long survey of bioaerosol quality in operating theatres (OT), hospital rooms (HR) and maternity wards (MW) at a hospital in Murcia, Spain, was performed. Total aerobic counts (TAC) and fungal load (FL) were assessed using a microbiological air sampler (MAS-100 single-stage impactor). While fungal levels were below 1 cfu/m3 (0–7.33 cfu/m3) in OT, they were higher in MW (mean, 6.9 cfu/m3; range 0.44–44.67 cfu/m3) and in HR (mean, 10.6 cfu/m3; range, 0–266 cfu/m3). In OT the aerobic counts were considerably higher, with a mean of 25.6 cfu/m3 (range, 1.67–157 cfu/m3). MW and HR also showed higher means for total aerobic counts compared to OT. Seasonal changes were not detected in mould and bacteria levels in OT. Hospital renovation occurred during this study and OT adjacent to renovated areas were closed. A survey of TAC and FL in OT resumed when renovation was completed. We observed an outstanding increase in FL (more than 100 cfu/m3), particularly Aspergillus spp., during this period, but no significant changes in TAC were observed after renovation.
Similar content being viewed by others
References
Alberti C, Bouakline A, Ribaud P et al (2001) Relationship between environmental fungal contamination and the incidence of invasive aspergillosis in haematology patients. J Hosp Infect 48:196–198
Augustowska M, Dutkiewicz J (2006) Variability of airborne microflora in a hospital ward within a period of one year. Ann Agric Environ Med 13:99–106
Bouza E, Peláez T, Pérez-Molina J et al (2002) Demolition of a hospital building by controlled explosion: the impact on filamentous fungal load in internal and external air. J Hosp Infect 52:234–242
Brunetti L, Santoro E, Cavallo P et al (2006) Two-years surveillance of fungal contamination in three hospital departments in Campania region. J Prev Med Hyg 47:22–25
Burge H (1990) Bioaerosols: prevalence and health effects in the indoor environment. J Allergy Clin Immunol 86:687–701
Chow TT, Yang XY (2005) Ventilation performance in the operating theatre against airborne infection: numerical study on an ultra-clean system. J Hosp Infect 59:138–147
Curtis L, Cali S, Conroy L et al (2005) Aspergillus surveillance project at a large tertiary-care hospital. J Hosp Infect 59:188–196
Dharan S, Pittet D (2002) Environmental control in operating theatres. J Hosp Infect 51:79–84
European Communities (1998) Good manufacturing practices—medicinal products for human and veterinary use (The rules governing medicinal products in the European Union), Vol 4. Office for Official Publications of the European Communities, Louxembourg
Falvey DG, Streifel AJ (2007) Ten-year air sample analysis of Aspergillus prevalence in a universitary hospital. J Hosp Infect 67:35–41
Feller W (1950) An introduction to the probability theory and its application. John Wiley and Sons, Inc., New York
Górny RL, Dutkiewicz J (2002) Bacterial and fungal aerosols in indoor environment in central and eastern European countries. Ann Agric Environ Med 9:17–23
ISO 14698-1 (2003) Cleanrooms and associated controlled environments-Biocontamination control, Part 1: general principles and methods
Kuhn DM, Ghannoum MA (2003) Indoor mould, toxigenic fungi and Stachybotrys chartarum: infectious disease perspective. Clin Microbiol Rev 16:144–172
Lee KS, Bartlett KH, Brauer M et al (2004) A field comparison of four samplers for enumerating fungal aerosols I sampling characteristics. Indoor Air 14:360–366
Li CS, Hou PA (2003) Bioaerosol characteristics in hospital clean rooms. Sci Total Environ 305:169–176
Loo VG, Bertrand C, Dixon C et al (1966) Control of construction-associated nosocomial aspergillosis in an antiquated hematology unit. Infect Control Hosp Epidemiol 17:360–364
Mahieu LM, De Dooy JJ, Van Laer FA et al (2000) A prospective study on factors influencing aspergillus spore load in the air during renovation works in a neonatal intensive care unit. J Hosp Infect 45:191–197
Mehta SK, Mishra SK, Pierson DL (1996) Evaluation of three portable samplers for monitoring airborne fungi. Appl Environ Microbiol 62:1835–1838
Morris G, Kokki MH, Anderson K et al (2000) Sampling of Aspergillus spores in air. J Hosp Infect 44:81–92
Nesa D, Lortholary J, Bouakline A et al (2001) Comparative performance of impactor air samplers for quantification of fungal contamination. J Hosp Infect 47:145–155
Nunes ZN, Martins AS, Altoe ALF et al (2005) Indoor air microbiological evaluation of offices, hospitals, industries and shopping centers. Mem Inst Oswaldo Cruz Rio de Janeiro 100:351–357
Panagopoulou P, Filioti J, Petrikkos G et al (2002) Environmental surveillance of filamentous fungi in three tertiary care hospitals in Greece. J Hosp Infect 52:185–191
Pasqualotto AC (2008) Differences in pathogenicity and clinical syndromes due to Aspergillus fumigatus and Aspergillus flavus. Med Mycol July:1–10
Pasqualotto AC, Denning DW (2006) Post-operative aspergillosis. Clin Microbiol Infect 12:1060–1076
Perdelli F, Cristina ML, Sartini M et al (2006) Fungal contamination in hospital environments. Infect Control Hosp Epidemiol 27:44–47
Pini G, Donato R, Faggi E et al (2004) Two years of a fungal aerobiocontamination survey in a Florentine haematology ward. Eur J Epidemiol 19:693–698
Samson R, Van Reenen-Hoekstra ES (1988) Introduction to food-borne fungi. Centraalburea Voor Schimmelcultures, The Netherlands
Singh N, Paterson DL (2005) Aspergillus infections in transplant recipients. Clin Microbiol Rev 18:44–69
Streifel AJ, Lauer JL, Vesley D et al (1983) Aspergillus fumigatus and other thermotolerant fungi generated by hospital building demolition. Appl Environ Microbiol 46:375–378
Takahashi T (1997) Airborne fungal colony-forming units in outdoor and indoor environments in Yokohama, Japan. Mycopathologia 139:23–33
Vanden Bergh MFQ, Verweij PE, Voss A (1999) Epidemiology of nosocomial fungal infections: invasive aspergillosis and the environment. Diagn Microbiol Infect Dis 34:221–227
Vonberg RP, Gastmeier P (2006) Nosocomial aspergillosis in outbreak settings. J Hosp Infect 63:246–254
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ortiz, G., Yagüe, G., Segovia, M. et al. A Study of Air Microbe Levels in Different Areas of a Hospital. Curr Microbiol 59, 53–58 (2009). https://doi.org/10.1007/s00284-009-9398-7
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00284-009-9398-7