Feasibility and Safety of Endovascular Stripping of Totally Implantable Venous Access Devices

  • Clinical Investigation
  • Published:
CardioVascular and Interventional Radiology Aims and scope Submit manuscript

Abstract

Purpose

To evaluate the safety and feasibility of percutaneous stripping of totally implantable venous access devices (TIVAD) in case of catheter-related sleeve and to report a technique to free the catheter tip from vessel wall adherence.

Materials and Methods

A total of 37 stripping procedures in 35 patients (14 men, 40%, and 21 women, 60%, mean age 53 ± 14 years) were reviewed. Totally implantable venous access devices were implanted because of malignancy in most cases (85.7%). Catheter-related sleeve was confirmed as cause of persistent catheter dysfunction despite instillation of thrombolytics. A technique to mobilize the catheter tip from the vessel wall was used when stripping with the snare catheter was impossible. Technical success, complication rate, and outcome were noted.

Results

A total of 55.9% (n = 19) of the 34 technically successful procedures (91.9%) could be done with the snare catheter. In 15 cases (44.1%), additional maneuvers to free the TIVAD’s tip from the vessel wall were needed. Success rate was not significantly lower before (72.4%) than after (96.7%) implementation of the new technique (P = 0.09). No complications were observed. Follow-up was available in 67.6% of cases. Recurrent catheter dysfunction was found in 17 TIVADs (78.3%) at a mean of 137.7 days and a median of 105 days.

Conclusions

Stripping of TIVADs is technically feasible and safe, with an overall success rate of 91.9%. Additional endovascular techniques to mobilize the distal catheter tip from the wall of the superior vena cava or right atrium to allow encircling the TIVAD tip with the snare catheter may be needed in 44.1% of cases.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Jordan K, Behlendorf T, Surov A et al (2008) Venous access ports: frequency and management of complications in oncology patients. Onkologie 31:404–410

    Article  PubMed  Google Scholar 

  2. Schutz JCL, Patel AA, Clark TWI et al (2004) Relationship between chest port catheter tip position and port malfunction after interventional radiologic placement. J Vasc Interv Radiol 15:581–587

    Article  PubMed  Google Scholar 

  3. Bessoud B, de baere T, Kuoch V et al (2003) Experience at a single institution with endovascular treatment of mechanical complications caused by implanted central venous access devices in pediatric and adult patients. AJR Am J Roentgenol 180:527–532

    PubMed  Google Scholar 

  4. Sobolevsky S, Sheiman RG, Faintuch S, Perry L (2007) Femoral-to-port through-and-through wire access to reestablish subcutaneous port function. AJR Am J Roentgenol 188:1047–1049

    Article  PubMed  Google Scholar 

  5. Baskin JL, Pui CH, Reiss U et al (2009) Management of occlusion and thrombosis associated with long-term indwelling central venous catheters. Lancet 374:159–169

    Article  PubMed  Google Scholar 

  6. Sacks D, McClenny TE, Cardella JF, Lewis CA (2003) Society of interventional radiology clinical practice guidelines. J Vasc Interv Radiol 14:S199–S202

    Article  PubMed  Google Scholar 

  7. Caers J, Fontaine C, Vinh-Hung V et al (2005) Catheter tip position as a risk factor for thrombosis associated with the use of subcutaneous infusion ports. Support Care Cancer 13:325–331

    Article  PubMed  Google Scholar 

  8. Cohn DE, Mutch DG, Rader JS et al (2001) Factors predicting subcutaneous implanted central venous port function: the relationship between catheter tip location and port failure in patients with gynecologic malignancies. Gynecol Oncol 83:533–536

    Article  PubMed  CAS  Google Scholar 

  9. Surov A, Jordan K, Buerke M et al (2008) Port catheter insufficiency: incidence and clinical–radiological correlations. Onkologie 31:455–461

    Article  PubMed  Google Scholar 

  10. Janne D’Othée B, Tham JC, Sheiman RG (2006) Restoration of patency in failing tunneled hemodialysis catheters: a comparison of catheter exchange, exchange and balloon disruption of the fibrin sheath, and femoral stripping. J Vasc Interv Radiol 17:1011–1015

    Article  PubMed  Google Scholar 

  11. Crain MR, Mewissen MW, Ostrowski GJ et al (1996) Fibrin sleeve stripping for salvage of failing hemodialysis catheters: technique and initial results. Radiology 198:41–44

    PubMed  CAS  Google Scholar 

  12. Haskal ZJ, Leen VH, Thomas-Hawkins C (1996) Transvenous removal of fibrin sheaths from tunneled hemodialysis catheters. J Vasc Interv Radiol 7:513–517

    Article  PubMed  CAS  Google Scholar 

  13. Rockall AG, Harris A, Wetton CW et al (1997) Stripping of failing haemodialysis catheters using the Amplatz gooseneck snare. Clin Radiol 52:616–620

    Article  PubMed  CAS  Google Scholar 

  14. Brady PS, Spence LD, Levitin A et al (1999) Efficacy of percutaneous fibrin sheath stripping in restoring patency of tunneled hemodialysis catheters. AJR Am J Roentgenol 173:1023–1027

    PubMed  CAS  Google Scholar 

  15. Gebauer B, Teichgräber UK, Podrabsky P et al (2007) Radiologic interventions for correction of central venous port catheter migrations. Cardiovasc Interv Radiol 30:216–221

    Article  Google Scholar 

Download references

Conflict of Interest

The authors declare that they have no conflict of interest.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sam Heye.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Heye, S., Maleux, G., Goossens, G.A. et al. Feasibility and Safety of Endovascular Stripping of Totally Implantable Venous Access Devices. Cardiovasc Intervent Radiol 35, 607–612 (2012). https://doi.org/10.1007/s00270-011-0158-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00270-011-0158-2

Keywords

Navigation