Skip to main content

A Novel Use of the AMPLATZER Vascular Plug: Preventing Bile Leak Following Inadvertent Subcapsular Deployment of a Biliary Stent

Abstract

The AMPLATZER Vascular Plug (AVP; AGA Medical, USA) is designed to provide optimal embolization of peripheral veins and arteries through single-device occlusion. There are no reported cases of the AVP’s being used to prevent bile leak. We report the successful use of the AVP within the liver to prevent intraperitoneal bile leak following inadvertent subcapsular stent deployment.

This is a preview of subscription content, access via your institution.

Fig. 1
Fig. 2

References

  1. Smilanich RP, Hafner GH (1994) Complications of biliary stents in obstructive pancreatic malignancies—a case report and review. Dig Dis Sci 39(12):2645–2649

    Article  CAS  PubMed  Google Scholar 

  2. Kawakami H, Uebayashi M, Konishi K et al (2008) A rare complication with extraction of proximally migrated biliary stent by using a basket catheter. Gastrointest Endosc 67(7):1170–1171 discussion 1172

    Article  PubMed  Google Scholar 

  3. Riddle C, Ahmed B, Doyle J et al (2008) Migration of Gelfoam to the gallbladder after liver biopsy. Pediatr Radiol 38(7):806–809

    Article  PubMed  Google Scholar 

  4. Doshi T, Mojtahedi A, Goswami GK et al (2009) Persistent cystic duct stump leak managed with hydrocoil embolisation. Cardiovasc Intervent Radiol 32(2):394–396

    Article  PubMed  Google Scholar 

  5. Tuite DJ, Kessel DO, Nicholson AA et al (2008) Initial clinical experience using the Amplatzer vascular plug. Cardiovasc Intervent Radiol 31(2):444–445

    Article  Google Scholar 

  6. Rimon U, Heldenberg E, Golan G et al (2008) Amplatzer Vascular Plug: expanding the applications spectrum. Cardiovasc Intervent Radiol 31(Suppl 2):S84–S87

    Article  PubMed  Google Scholar 

  7. Pellerin O, Caruba T, Kandounakis Y et al (2008) Embolization of the internal iliac artery: cost-effectiveness of two different techniques. Cardiovasc Intervent Radiol 31(6):1088–1093

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Roberta Dionello.

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Dionello, R., Warakaulle, D. & Liong, WC. A Novel Use of the AMPLATZER Vascular Plug: Preventing Bile Leak Following Inadvertent Subcapsular Deployment of a Biliary Stent. Cardiovasc Intervent Radiol 33, 213–214 (2010). https://doi.org/10.1007/s00270-009-9605-8

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00270-009-9605-8

Keywords