Abstract

The purpose of this study was to simplify a fluoroscopy guided gastrostomy technique using pull-type tubes which are traditionally introduced with gastroscopic assistance. The stomach was transorally probed with a 5-Fr catheter and a guidewire. A second access was performed percutaneously through the anterior abdominal and gastric wall using an 8-Fr sheath and an 8-Fr guiding catheter. A duplicated guidewire was introduced through the guiding catheter in order to result in a great custom-made loop within the stomach. The transoral guidewire was captured and tightened with this loop and the guiding catheter, and both were subsequently pulled by the transoral guidewire until the tip of the guiding catheter exited the mouth. A thread was fed through the guiding catheter for fixation of the pull-type gastrostomy tube. Finally, the fixed tube was pulled through the esophagus into the stomach and through the abdominal wall until the anterior gastric wall fixed the retention plate of the tube. Thirty-seven patients (28 male, 9 female; age, 65.1 ± 14.4 years) with miscellaneous indications for percutaneous gastrostomies were supplied with pull-type gastrostomy catheters in a fluoroscopy technique without endoscopic assistance. Twenty-five of the 37 patients (67.6%) had undergone unsuccessful preceding gastroscopically guided PEG attempts because of tumor stenosis (= 12) or impossible transillumination of the abdominal wall (= 13). All procedures were technically successful, without major complications. Particularly, all patients with frustrating gastroscopic attempts were successfully provided with pull-type gastrostomy tubes. Five minor complications occurred: one tube loss during the passage of the hypopoharynx because of a torn thread, one transient small leakage alongside the tube (both successfully treated), and three cases of transient moderate local pain without leakage (symptomatic treatment). We conclude that this fluoroscopy-guided pull-through gastrostomy technique is easy and safe to perform and may be suggested as a standard procedure for radiological gastrostomies. It combines the ease of the radiological approach with the advantages of the pull-type tube devices, particularly the benefits of the typical retention plates.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Silas AM, Pearce LF, Lestina LS, Grove MR, Tosteson A, Manganiello WD, Bettmann MA, Gordon SR (2005) Percutaneous radiologic gastrostomy versus percutaneous endoscopic gastrostomy: a comparison of indications, complications and outcomes in 370 patients. Eur J Radiol 56:84–90

    Article  PubMed  Google Scholar 

  2. Gauderer MWL, Ponsky JL, Izant RJ (1980) Gastrostomy without laparotomy: a percutaneous endoscopic technique. J Pediatr Surg 15:872–875

    Article  PubMed  CAS  Google Scholar 

  3. Pershaw RM (1981) A percutaneous method for inserting a feeding gastrostomy tube. Surg Gynecol Obstet 152:658–660

    Google Scholar 

  4. Cosentini ER, Sautner T, Gnant M, et al. (1998) Outcomes of surgical, percutaneous endoscopic, and percutaneous radiological gastrostomies. Arch Surg 133:1076–1083

    Article  PubMed  CAS  Google Scholar 

  5. Stern JS (1986) Comparison of percutaneous endoscopic gastrostomy with surgical gastrostomy at a community hospital. Am J Gastroenterol 207:598–603

    Google Scholar 

  6. Given MF, Hanson JJ, Lee MJ (2005) Interventional radiology techniques for provision of enteral feeding. CardioVasc Interv Radiol 28:692–703

    Article  CAS  Google Scholar 

  7. Sanchez RB, van Sonnenberg E, D’Agostino HB, Goodacre BW, Moyers P, Casola G (1992) CT-guidance for percutaneous gastrostomy and gastroenterostomy. Radiology 184:201–205

    PubMed  CAS  Google Scholar 

  8. Tsukuda T, Fujita T, Ito K, Yamashita T, Matsunaga N (2006) Percutaneous radiologic gastrostomy using the push-type gastrostomy tubes with CT and fluoroscopic guidance. AJR 186:574–576

    Article  PubMed  Google Scholar 

  9. Thornton FJ, Varghese JC, Haslam PJ, McGrath FP, Keeling F, Lee MJ (2000) Percutaneous gastrostomy in patients who fail or are unsuitable for endoscopic gastrostomy. CardioVasc Interv Radiol 23:279–284

    Article  CAS  Google Scholar 

  10. Trerotola SO, Shah N, Johnson MS, et al. (1998) Single-step dilatation for a large bore percutaneous gastrostomy and gastrojejunostomy. J Vasc Interv Radiol 9:579–582

    Article  PubMed  CAS  Google Scholar 

  11. Hicks ME, Surratt RS, Picus D, Marx MV, Lang EV (1999) Fluoroscopically guided percutaneous gastrostomy and gastroenterostomy: analysis of 158 consecutive cases. AJR 154:725–728

    Google Scholar 

  12. Lyon SM, Haslam PJ, Duke DM, et al. (2003) De novo placement of button gastrostomy catheters in a adult population: experience in 53 patients. J Vasc Interv Radiol 14:1283–1289

    PubMed  Google Scholar 

  13. Shaw AS, Ampong MA, Rio A, et al. (2004) Entristar skin-level gastrostomy tube: primary placement with radiological guidance in patients with amyotrophic lateral sclerosis. Radiology 233:392–399

    Article  PubMed  Google Scholar 

  14. Brown AS, Mueller PR, Ferrucci JT (1986) Controlled percutaneous gastrostomy: nylon T-fasteners for fixation of the anterior gastric wall. Radiology 158:544–545

    Google Scholar 

  15. Dewald CL, Hiette PO, Sewall LE, Fredenberg PG, Palestrant AM (1999) Percutaneous gastrostomies and gastrojejunostomy woth gastropexy: experience in 701 procedures. Radiology 211:651–666

    PubMed  CAS  Google Scholar 

  16. Kavin H, Messersmiths R (2006) Radiologic percutaneous gastrostomy and gastrojejunostomy with T-fastener gastropexy: aspects of importance to the endoscopist. Am J Gastroenterol 101:2155–2159

    Article  PubMed  Google Scholar 

  17. Thornton FJ, Fotheringham T, Haslam PJ, et al. (2002) Percutaneous radiological gastrostomy with and withour T-Fastener gastropexy. A randomized comparison study. CardioVasc Interv Radiol 25:467–471

    Article  CAS  Google Scholar 

  18. Rosenzweig TB, Palestrant AM, Esplin CA, Gilsdorf RB (1994) A method for radiologic-assited gastrostomy when percutaneous endoscopic gastrostomy is contraindicated. Am J Surg 168:587–590

    Article  PubMed  CAS  Google Scholar 

  19. Towbin RB, Ball WS, Bissett GS (1988) Percutaneous gastrostomy and percutaneous gastrojejunostomy in children: antegrade approach. Radiology 168:473–476

    PubMed  CAS  Google Scholar 

  20. Szymski GX, Albazzaz AN, Funaki B, Rosenblum JD, Hackworth CA, Zernich BW, Leef JA (1997) Radiologically guided placement of pull-type gastrostomy tubes. Radiology 205:669–673

    PubMed  CAS  Google Scholar 

  21. Laasch HU, Wilbraham L, Bullen K, Marriott A, Lawrance AL, Johnson R, Lee SH, England RE, Gamble GE, Martin DF (2003) Gastrsotomy insertion: comparing the options—PEG, RIG or PIG? Clin Radiol 58:398–405

    Article  PubMed  Google Scholar 

  22. Cappell MS (2007) Risk factors and risk reduction of malignant seeding of the percutaneous endoscopic gastrostomy track from pharyngoesophageal malignancy: a review of all 44 known reported cases. Am J Gastroenterol 102:1307–1311

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. B. Pitton.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pitton, M.B., Herber, S. & Düber, C. Fluoroscopy-Guided Pull-Through Gastrostomy. Cardiovasc Intervent Radiol 31, 142–148 (2008). https://doi.org/10.1007/s00270-007-9179-2

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00270-007-9179-2

Keywords

Navigation