Abstract
A 74-year-old male claudicant who had a significant abdominal aortic stenosis was hydrated before aortic stent placement because of an elevated creatinine level. During the intervention the patient experienced acute abdominal pain with vomiting. No vascular cause was detected. Due to persistant pain, plain radiography and an abdominal CT scan were performed a few hours after the procedure. Images revealed a bilateral renal fornix rupture with a large retroperitoneal fluid collection. The patient was treated conservatively with ureteral double-J placement and percutaneous nephrostomy. The further course was uneventful and the patient was discharged 2 weeks later free of symptoms. Renal fornix rupture is a very rare complication after contrast medium application that can be treated without surgery.
Similar content being viewed by others
References
G Traumann DR Holsten G Berndt (1972) ArticleTitleExtravasation from fornix rupture during infusion urography ROEFO Fortschr Roentgenstr 117 429–433 Occurrence Handle1:STN:280:CSyD3s3mtlI%3D
ME Bernardino BL Clennan (1976) ArticleTitleHigh dose urography: incidence and relationship to spontaneous peripelvic extravasation Am J Roentgenol 127 373–376 Occurrence Handle1:STN:280:CSmB2srltlA%3D
R Fluckiger M Gunst (1989) ArticleTitleFornix rupture. A contribution to differential acute abdomen diagnosis Helv Chir Acta 56 361–364 Occurrence Handle1:STN:280:By%2BD3snhsFQ%3D Occurrence Handle2807968
RM Friedenberg H Moorehouse M Gade (1983) ArticleTitleUrinomas secondary to pyelosinus backflow Urol Radiol 5 23–29 Occurrence Handle1:STN:280:BiyC2szisVQ%3D Occurrence Handle6836788
JJ Smulewicz J Dorfman S Cagan WH Seery (1970) ArticleTitleSpontaneous rupture of the collecting system of the kidney: an evaluation J Urol 104 507–511 Occurrence Handle1:STN:280:CS6D38njt1M%3D Occurrence Handle5476462
E Walter KJ Wolf S Grehn (1979) ArticleTitleLong-term follow-up after spontaneous contrast extravasation during infusion urograms ROEFO Foertschr Roentgenstr 131 17–23 Occurrence Handle1:STN:280:Bi%2BD3crgsFQ%3D
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Niggemann, P., Brehmer, B. & Schuermann, K. Bilateral Renal Fornix Rupture Following Intraarterial Contrast Medium Application for Infrarenal Aortic Stent Placement. Cardiovasc Intervent Radiol 29, 157–159 (2006). https://doi.org/10.1007/s00270-004-0006-8
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00270-004-0006-8