Abstract
Purpose: To evaluate the deliverability and protection capabilities of an embolism protection filter in angioplasty of peripheral arteries. Methods: The Angioguard emboli capture guidewire system was applied in 11 patients with femoropopliteal lesions (6 stenoses, 3 occlusions, 2 controls). Data on lesion crossing, flow deceleration and macroembolization were recorded. Filter membranes were evaluated with scanning electron microscopy (SEM). Results: System delivery was successful in all patients. Primary lesion crossing was feasible in four of six stenoses; predilatation was required in two of six. Marked flow deceleration was recorded in six patients. Emboli next to the filter were detected in each patient with concentric plaques, but could not reliably be removed with the filter. Downstream macroembolization was also present in all patients with concentric stenoses, but in none with chronic occlusion. None of the patients had clinical signs of ischemia. SEM analysis demonstrated only small particles on control group filters and non-obliterating fibrinous conglomerates on filters used in chronic occlusion. Substantial obliteration was seen on several filters used in stenotic lesions. Conclusion: Microembolization of fibrin aggregates is a common incident in balloon angioplasty of femoropopliteal stenoses. Macroembolization occurred more frequently than previously reported. The use of embolism protection filters aided in the detection but not in the removal of larger emboli.
Similar content being viewed by others
References
JG Théron GG Payelle O Coskun HF Huet L Guimaraens (1996) ArticleTitleCarotid artery stenosis: Treatment with protected balloon angioplasty and stent placement. Radiology 201 627–636 Occurrence Handle1:STN:280:ByiD1MzmslU%3D Occurrence Handle8939208
S. Müller-Hülsbeck (2002) ArticleTitleCerebral protection devices for treatment of carotid stenoses: Where do we stand today? Fortschr Röntgenstr 174 945–954
B Reimers N Corvaja S Moshiri S Saccà R Albiero C Di Mario P Pascotto A Colombo (2001) ArticleTitleCerebral protection with filter devices during carotid artery stenting. Circulation 104 12–15 Occurrence Handle1:STN:280:DC%2BD3MznvVyluw%3D%3D Occurrence Handle11435330
T Ohki GS Roubin FJ Veith SS Iyer E Brady (1999) ArticleTitleEfficacy of a filter device in the prevention of embolic events during carotid angioplasty and stenting. J Vasc Surg 30 1034–1044 Occurrence Handle1:STN:280:DC%2BD3c%2FlsVKlsg%3D%3D Occurrence Handle10587387
A Higginson F Alaeddin G Fishwick A Bolia (2001) ArticleTitle“Push and park”: An alternative strategy for management of embolic complication during balloon angioplasty. Eur J Vasc Endovasc Surg 21 279–282 Occurrence Handle10.1053/ejvs.2001.1324 Occurrence Handle1:STN:280:DC%2BD3M3ltlSkuw%3D%3D Occurrence Handle11352690
JC McDermott AB Crummy (1994) ArticleTitleComplications of angioplasty. Semin Interv Radiol 11 145–149
GJ Becker BT Katzen MD Dake (1989) ArticleTitleNoncoronary angioplasty. Radiology 170 921–940 Occurrence Handle1:STN:280:BiaC38bjvFM%3D Occurrence Handle2521745
HC Stary AB Chandler RE Dinsmore V Fuster S Glagov W Insull Jr ME Rosenfeld CJ Schwartz WD Wagner RW Wissler (1995) ArticleTitleA definition of advanced types of atherosclerotic lesions and a histological classification of atherosclerosis. Circulation 92 1355–1374 Occurrence Handle1:STN:280:ByqA2snnvVc%3D Occurrence Handle7648691
PVP Sharma SC Babu PM Shah ZE Nassoura (1996) ArticleTitleChanging patterns of atheroembolism. Cardiovasc Surg 4 573–579 Occurrence Handle10.1016/0967-2109(96)00003-8 Occurrence Handle1:STN:280:ByiD28njtlY%3D Occurrence Handle8909813
AJ McCleary M Nelson NM Dearden TAJ Calvey MJ Gough (1998) ArticleTitleCerebral haemodynamics and embolization during carotid angioplasty in high-risk patients. Br J Surg 85 771–774 Occurrence Handle10.1046/j.1365-2168.1998.00723.x Occurrence Handle1:STN:280:DyaK1czjtVakug%3D%3D Occurrence Handle9667704
WD Jordan DC Voellinger DD Doblar NP Plyushcheva WS Fisher HA McDowell (1999) ArticleTitleMicroemboli detected by transcranial Doppler monitoring in patients during carotid angioplasty versus carotid endarterectomy. Cardiovasc Surg 7 33–38 Occurrence Handle10.1016/S0967-2109(98)00097-0 Occurrence Handle1:STN:280:DyaK1M7ntFOltw%3D%3D Occurrence Handle10073757
P Abraham P L’hoste A Pasco-Papon JL Saumet (1996) ArticleTitleAsymptomatic peripheral embolism during balloon angioplasty. AJR Am J Roentgenol 166 1230–1231 Occurrence Handle1:STN:280:BymC1MjhvVA%3D
FE Zanella J Berkefeld (2000) ArticleTitleProtected carotid stenting. Z Kardiol 89 IssueIDSuppl 8 47–52
JB Martin JC Pache M Treggiari-Venzi KJ Murphy P Gailloud E Puget G Pizzolato K Sugiu L Guimaraens J Théron DA Rüfenacht (2001) ArticleTitleRole of distal balloon protection technique in the prevention of cerebral embolic events during carotid stent placement. Stroke 32 479–484 Occurrence Handle1:STN:280:DC%2BD3M3msFCitA%3D%3D Occurrence Handle11157186
T Ohki ML Marin RT Lyon GL Berdejo K Soundararajan M Ohki JG Yuan PL Faries RA Wain LA Sanchez WD Suggs FJ Veith (1998) ArticleTitleEx vivo human carotid bifurcation stenting: Correlation of lesion characteristics with embolic potential. J Vasc Surg 27 463–471 Occurrence Handle1:STN:280:DyaK1c3gs1ejtQ%3D%3D Occurrence Handle9546231
HI Manninen HAT Räsänen RL Vanninen P Vainio M Hippeläinen VM Kosma (1999) ArticleTitleStent placement versus percutaneous transluminal angioplasty of human carotid arteries in cadavers in situ: Distal embolization and findings at intravascular US, MR imaging, and histopathologic analysis. Radiology 212 483–492 Occurrence Handle1:STN:280:DyaK1MzlvVegug%3D%3D Occurrence Handle10429707
S Al-Hamali P Baskerville S Fraser H Walters HS Markus (1999) ArticleTitleDetection of distal emboli in patients with peripheral arterial stenosis before and after iliac angioplasty. J Vasc Surg 29 345–351 Occurrence Handle1:STN:280:DyaK1M7jslyktg%3D%3D Occurrence Handle9950992
G Tepe U Hahn B Pusich C König M Müller-Schimpfle S Raygrotzki CD Claussen SH Duda (2001) ArticleTitleNew strategies in platelet inhibition in noncoronary interventions. Semin Vasc Surg 14 143–149 Occurrence Handle10.1053/svas.2001.23171 Occurrence Handle1:STN:280:DC%2BD3Mzjt1aktQ%3D%3D Occurrence Handle11400090
Acknowledgements
We thank Cordis (Haan, Germany; a Johnson & Johnson Company, Warren, NJ, USA) for providing the AngioGuard devices. We are grateful to Michael Bretzke for assistance with the study.
Presented at CIRSE annual meeting, September 22–26, 2001, Gothenburg, Sweden.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
König, C., Pusich, B., Tepe, G. et al. Frequent Embolization in Peripheral Angioplasty: Detection with an Embolism Protection Device (AngioGuard) and Electron Microscopy . CVIR 26, 334–339 (2003). https://doi.org/10.1007/s00270-003-2656-3
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00270-003-2656-3