Abstract
Endovascular stenting has emerged as an effective alternative for unsuccessful angioplasty of the aorta in aortoarteritis. This is a single case report of fatal aortic rupture following balloon angioplasty of post-patch aortoplasty restenosis in aortoarteritis. We report a fatal aortic rupture during angioplasty of the primarily stented stenotic segment of the aorta in a case of aortoarteritis.
Similar content being viewed by others
References
S Tyagi UA Kaul M Nair KK Sethi R Arora M Khalilullah (1992) ArticleTitleBalloon angioplasty of the aorta in Takayasu’s arteritis: Initial and long-term results. Am Heart J 124 87–82 Occurrence Handle10.1016/0002-8703(92)90924-K Occurrence Handle1615832
T Berger R Sorensen J Konrad (1986) ArticleTitleAortic rupture: A complication of transluminal angioplasty. AJR 146 373–374 Occurrence Handle1:STN:280:BimC3c%2FhvFc%3D Occurrence Handle2934960
S Tyagi UA Kaul R Arora (1999) ArticleTitleEndovascular stenting for unsuccessful angioplasty of the aorta in aortoarteritis. Cardiovasc Intervent Radiol 22 IssueID6 452–456 Occurrence Handle10.1007/s002709900431 Occurrence Handle10556402
S Sharma JR Pinto (1995) ArticleTitleFatal aortic rupture following balloon angioplasty of aortic restenosis in aortoarteritis. Cathet Cardiovasc Diagn 36 132–133 Occurrence Handle1:STN:280:BymC3M7htFw%3D Occurrence Handle8829834
PS Rao (1993) ArticleTitleAortic rupture after balloon angioplasty of aortic coarctation (editorial). Am Heart J 125 1205–1206 Occurrence Handle10.1016/0002-8703(93)90150-8 Occurrence Handle1:STN:280:ByyB38%2FmtFU%3D Occurrence Handle8465764
DH Roberts CM Bellamy DR Ramsdale (1993) ArticleTitleFatal aortic rupture during balloon dilatation of recoarctation. Am Heart J 125 1181–1182 Occurrence Handle10.1016/0002-8703(93)90139-Z Occurrence Handle1:STN:280:ByyB38%2FmtVQ%3D Occurrence Handle8465753
Tyagi Sanjay Rangesetty Umamahesh C. Kaul Upkar A. (2003) ArticleTitleEndovascular treatment of aortic rupture during angioplasty for aortic in-stent restenosis in aortoarteritis. Cathet Cardiovasc Intervent 58 IssueID1 103–106 Occurrence Handle10.1002/ccd.10396
KA Krabill JL Bass RV Lucas Jr JE Edwards (1987) ArticleTitleDissecting transverse aortic arch aneurysm after percutaneous transluminal balloon dilatation angioplasty of an aortic coarctation. Pediatr Cardiol 8 39–42 Occurrence Handle1:STN:280:BiiB28%2FivVM%3D Occurrence Handle2955289
RF Colapinto EP Harries-Jones KW Johnston (1980) ArticleTitlePercutaneous transluminal dilatation and recanalization in the treatment of peripheral vascular disease. Radiology 135 583–587 Occurrence Handle1:STN:280:Bi%2BB3M3osFI%3D Occurrence Handle7384439
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Deshmukh, H., Rathod, K., Sheth, R. et al. Fatal Aortic Rupture Complicating Stent Plasty in a Case of Aortoarteritis . CVIR 26, 496–498 (2003). https://doi.org/10.1007/s00270-003-0063-4
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00270-003-0063-4