Abstract

To assess the accuracy and efficacy of intravascular ultrasound guidance obtained by an intracardiac ultrasound probe during complex aortic endografting. Between November 1999 and July 2002, 19 patients (5 female, 14 male; mean age 73.5 ± 2.1 years) underwent endovascular repair of thoracic (n = 10), complex abdominal (n = 6) and concomitant thoraco-abdominal (n = 3) aortic aneurysm. The most suitable size and configuration of the stent-graft were chosen on the basis of preoperative computed tomographic angiography (CTA) or magnetic resonance angiography (MRA). Intraoperative intravascular ultrasound imaging was obtained using a 9 Fr, 9 MHz intracardiac echocardiography (ICE) probe, 110 cm in length, inserted through a 10 Fr precurved long sheath. The endografts were deployed as planned by CTA or MRA. Before stent-graft deployment, the ICE probe allowed us to view the posterior aortic arch and descending thoraco-abdominal aorta without position-related artifacts, and to identify both sites of stent-graft positioning. After stent-graft deployment, the ICE probe allowed us to detect the need for additional modular components to internally reline the aorta in 11 patients, and to discover 2 incomplete graft expansions subsequently treated with adjunctive balloon angioplasty. In 1 patient, the ICE probe supported the decision that the patient was ineligible for the endovascular exclusion procedure. The ICE probe provides accurate information on the anatomy of the posterior aortic arch and thoracic and abdominal aortic aneurysms and a rapid identification of attachment sites and stent-graft pathology, allowing refinement and improvement of the endovascular strategy.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Figure 1
Figure 2
Figure 3

Similar content being viewed by others

References

  1. DM Moskowitz RA Kahn SN Konstadt et al. (1999) ArticleTitleIntraoperative transesophageal echocardiography as an adjunctive to fluoroscopy during endovascular thoracic aortic repair Eur J Vasc Endovasc Surg 17 22–27 Occurrence Handle10.1053/ejvs.1998.0661 Occurrence Handle10071613

    Article  PubMed  Google Scholar 

  2. K Orihashi Y Matsuura T Sueda et al. (2000) ArticleTitleEchocardiography-assisted surgery in transaortic endovascular stent grafting: Role of transesophageal echocardiography J Thorac Cardiovasc Surg 120 672–678 Occurrence Handle10.1067/mtc.2000.109237 Occurrence Handle1:STN:280:DC%2BD3M%2FhsFyhsA%3D%3D Occurrence Handle11003747

    Article  CAS  PubMed  Google Scholar 

  3. C Rapezzi G Rocchi R Fattori et al. (2001) ArticleTitleUsefulness of transesophageal echocardiography monitoring to improve the outcome of stent-graft treatment of thoracic aortic aneurysms Am J Cardiol 87 315–319 Occurrence Handle10.1016/S0002-9149(00)01365-5 Occurrence Handle1:STN:280:DC%2BD3M7is1OntA%3D%3D Occurrence Handle11165967

    Article  CAS  PubMed  Google Scholar 

  4. T Lie J Lundbom S Hatlinghus et al. (1997) ArticleTitleUltrasound imaging during endovascular abdominal aortic aneurysm repair using Stentor bifurcated endograft J Endovasc Surg 4 272–278 Occurrence Handle10.1583/1074-6218(1997)004<0272:UIDEAA>2.0.CO;2 Occurrence Handle1:STN:280:ByiH3snjvVE%3D Occurrence Handle9291052

    Article  CAS  PubMed  Google Scholar 

  5. RA White C Donayre G Kopchok et al. (1997) ArticleTitleIntravascular ultrasound: The ultimate tool for abdominal aortic aneurysm assessment and endovascular graft delivery J Endovasc Surg 4 45–55 Occurrence Handle10.1583/1074-6218(1997)004<0045:IUTUTF>2.0.CO;2 Occurrence Handle1:STN:280:ByiC1cjks1I%3D Occurrence Handle9034919

    Article  CAS  PubMed  Google Scholar 

  6. KC Vogt J Brunkwall M Malina et al. (1997) ArticleTitleThe use of intravascular ultrasound as control procedure for the deployment of endovascular stented grafts Eur J Vasc Endovasc Surg 13 592–596 Occurrence Handle1:STN:280:ByiA2sbptFA%3D Occurrence Handle9236713

    CAS  PubMed  Google Scholar 

  7. Essen JA van der Lugt A van EJ Gussenhoven et al. (1998) ArticleTitleIntravascular ultrasonography allows accurate assessment of abdominal aortic aneurysm: an in vitro validation study J Vasc Surg 27 347–353 Occurrence Handle9510290

    PubMed  Google Scholar 

  8. DW Losordo K Rosenfield A Pieczek et al. (1992) ArticleTitleHow does angioplasty work? Serial analysis of human iliac arteries using intravascular ultrasound Circulation 86 1845–1858 Occurrence Handle1:STN:280:ByyD1c3osFM%3D Occurrence Handle1451257

    CAS  PubMed  Google Scholar 

  9. EJ Gussenhoven A van der Lugt G Pasterkamp et al. (1995) ArticleTitleIntravascular ultrasound predictors of outcome after peripheral balloon angioplasty Eur J Vasc Endovasc Surg 10 279–288 Occurrence Handle1:STN:280:BymD3c%2FhtVM%3D Occurrence Handle7552525

    CAS  PubMed  Google Scholar 

  10. A van der Lugt EJ Gussenhoven T Stijnen et al. (1995) ArticleTitleComparison of intravascular ultrasonic findings after coronary balloon angioplasty evaluated in vitro with histology Am J Cardiol 76 661–666 Occurrence Handle10.1016/S0002-9149(99)80193-3 Occurrence Handle1:STN:280:BymD3Mnjt1I%3D Occurrence Handle7572621

    Article  CAS  PubMed  Google Scholar 

  11. E Chu AP Fitzpatrick MC Chin et al. (1994) ArticleTitleRadiofrequency catheter ablation guided by intracardiac echocardiography Circulation 89 1301–1305 Occurrence Handle1:STN:280:ByuC2s%2FkvFQ%3D Occurrence Handle8124819

    CAS  PubMed  Google Scholar 

  12. E Chu JM Kalman MA Kwasman et al. (1994) ArticleTitleIntracardiac echocardiography during radiofrequency catheter ablation of cardiac arrhythmias in humans J Am Coll Cardiol 24 1351–1357 Occurrence Handle1:STN:280:ByqD3MrkvVY%3D Occurrence Handle7930260

    CAS  PubMed  Google Scholar 

  13. JM Kalman RJ Lee WG Fisher et al. (1995) ArticleTitleRadiofrequency catheter modification of sinus pacemaker function guided by intracardiac echocardiography Circulation 92 3070–3081 Occurrence Handle1:STN:280:BymD2s7jtlM%3D Occurrence Handle7586278

    CAS  PubMed  Google Scholar 

  14. JM Kalman JE Olgin MR Karch et al. (1997) ArticleTitleUse of intracardiac echocardiography in interventional electrophysiology Pacing Clin Electrophysiol 20 2248–2262 Occurrence Handle1:STN:280:ByiH2MrjvFc%3D Occurrence Handle9309751

    CAS  PubMed  Google Scholar 

  15. JE Olgin JM Kalman M Chin et al. (1997) ArticleTitleElectrophysiological effects of long, linear atrial lesions placed under intracardiac ultrasound guidance Circulation 96 2715–2721 Occurrence Handle1:STN:280:DyaK1c%2FhsF2qsw%3D%3D Occurrence Handle9355914

    CAS  PubMed  Google Scholar 

  16. JM Kalman JE Olgin MR Karch et al. (1998) ArticleTitle“Cristal tachycardias”: Origin of right atrial tachycardias from the crista terminalis identified by intracardiac echocardiography J Am Coll Cardiol 31 451–459 Occurrence Handle10.1016/S0735-1097(97)00492-0 Occurrence Handle1:STN:280:DyaK1c7it1Chtg%3D%3D Occurrence Handle9462592

    Article  CAS  PubMed  Google Scholar 

  17. JF Ren D Schwartzman D Callans et al. (1998) ArticleTitleImaging technique and clinical utility for electrophysiologic procedures of lower frequency (9 MHz) intracardiac echocardiography Am J Cardiol 82 1557–1560 Occurrence Handle10.1016/S0002-9149(98)00709-7 Occurrence Handle1:STN:280:DyaK1M%2FovFCltQ%3D%3D Occurrence Handle9874071

    Article  CAS  PubMed  Google Scholar 

  18. LM Epstein MA Mitchell TW Smith et al. (1998) ArticleTitleComparative study of fluoroscopy and intracardiac echocardiographic guidance for the creation of linear atrial lesions Circulation 98 1796–1801 Occurrence Handle1:STN:280:DyaK1M%2FgsFCisQ%3D%3D Occurrence Handle9788836

    CAS  PubMed  Google Scholar 

  19. TJ Cohen B Ibrahim J Lazar J Rosen J Klein (1999) ArticleTitleUtility of intracardiac echocardiography (ICE) in electrophysiology: ICEing the CAKE (Catheter Ablation Knowledge Enhancement) J Invasive Cardiol 11 364–368 Occurrence Handle10745552

    PubMed  Google Scholar 

  20. PA Friedman D Luria AM Fenton et al. (2000) ArticleTitleGlobal right atrial mapping of human atrial flutter: The presence of posteromedial (sinus venosa region) functional block and double potentials: A study in biplane fluoroscopy and intracardiac echocardiography Circulation 101 1568–1577 Occurrence Handle1:STN:280:DC%2BD3c3htFenug%3D%3D Occurrence Handle10747351

    CAS  PubMed  Google Scholar 

  21. JF Mitchel LD Gillam BW Sanzobrino et al. (1995) ArticleTitleIntracardiac ultrasound imaging during transseptal catheterization Chest 108 104–108 Occurrence Handle1:STN:280:ByqA3s%2FpvVI%3D Occurrence Handle7606942

    CAS  PubMed  Google Scholar 

  22. LM Epstein T Smith H TenHoff (1998) ArticleTitleNonfluoroscopic transseptal catheterization: safety and efficacy of intracardiac echocardiographic guidance J Cardiovasc Electrophysiol 9 625–630 Occurrence Handle1:STN:280:DyaK1czhs1yjsw%3D%3D Occurrence Handle9654229

    CAS  PubMed  Google Scholar 

  23. ZM Hijazi Z Wang QL Cao (2001) ArticleTitleTranscatheter closure of atrial septal defects and patent foramen ovale under intracardiac echocardiographic guidance: Feasibility and comparison with transesophageal echocardiography Cathet Cardiovasc Intervent 52 194–199 Occurrence Handle10.1002/1522-726X(200102)52:2<194::AID-CCD1046>3.3.CO;2-W Occurrence Handle1:STN:280:DC%2BD3M3jt1yjug%3D%3D

    Article  CAS  Google Scholar 

  24. M Zanchetta E Onorato G Rigatelli et al. (2001) ArticleTitleUse of Amplatzer septal occluder in a case of residual atrial septal defect causing bidirectional shunting after percutaneous Inoue mitral balloon valvuloplasty J Invasive Cardiol 13 223–226 Occurrence Handle1:STN:280:DC%2BD3M3gvVWjuw%3D%3D Occurrence Handle11231648

    CAS  PubMed  Google Scholar 

  25. HG Beebe (1997) ArticleTitleImaging modalities for aortic endografting J Endovasc Surg 4 111–123 Occurrence Handle10.1583/1074-6218(1997)004<0111:IMFAE>2.0.CO;2 Occurrence Handle1:STN:280:ByiA38fks1U%3D Occurrence Handle9184999

    Article  CAS  PubMed  Google Scholar 

  26. YG Wolf M Tillich WA Lee et al. (2001) ArticleTitleImpact of aortoiliac tortuosity on endovascular repair of abdominal aortic aneurysms: Evaluation of 3D computer-based assessment J Vasc Surg 34 594–599 Occurrence Handle10.1067/mva.2001.118586 Occurrence Handle1:STN:280:DC%2BD3MrmsFaltQ%3D%3D Occurrence Handle11668310

    Article  CAS  PubMed  Google Scholar 

  27. R Balm R Kaatee JD Blankensteijn et al. (1996) ArticleTitleCT-angiography of abdominal aortic aneurysms after transfemoral endovascular aneurysm management Eur J Vasc Endovasc Surg 12 182–188 Occurrence Handle1:STN:280:BymA2cjptlU%3D Occurrence Handle8760980

    CAS  PubMed  Google Scholar 

  28. MF Fillinger (2000) ArticleTitleImaging of the thoracic and thoracoabdominal aorta Semin Vasc Surg 13 247–263 Occurrence Handle1:STN:280:DC%2BD3M3gtFCnsw%3D%3D Occurrence Handle11156053

    CAS  PubMed  Google Scholar 

  29. MF Fillinger (1999) ArticleTitleNew imaging techniques in endovascular surgery Surg Clin North Am 79 451–475 Occurrence Handle1:STN:280:DyaK1MzjvVyksg%3D%3D Occurrence Handle10410681

    CAS  PubMed  Google Scholar 

  30. RA White CE Donayre I Walot et al. (2001) ArticleTitleComputed tomography assessment of abdominal aortic aneurysm morphology after endograft exclusion J Vasc Surg 33[2 Suppl] S1–10 Occurrence Handle10.1067/mva.2001.111680

    Article  Google Scholar 

  31. R Balm R Stokking R Kaatee et al. (1997) ArticleTitleComputed tomographic angiographic imaging of abdominal aortic aneurysms: Implications for transfemoral endovascular aneurysm management J Vasc Surg 26 231–237 Occurrence Handle1:STN:280:ByiH38risF0%3D Occurrence Handle9279309

    CAS  PubMed  Google Scholar 

  32. C Verbin M Scoccianti G Kopchok et al. (1995) ArticleTitleComparison of the utility of CT scans and intravascular ultrasound in endovascular aortic grafting Ann Vasc Surg 9 434–440 Occurrence Handle1:STN:280:BymD1MbpsVQ%3D Occurrence Handle8541191

    CAS  PubMed  Google Scholar 

  33. R White C Donayre I Walot et al. (1997) ArticleTitleEndograft repair of an aortic pseudoaneurysm following gunshot wound injury: Impact of imaging on diagnosis and planning of intervention J Endovasc Surg 4 344–351 Occurrence Handle10.1583/1074-6218(1997)004<0344:EROAAP>2.0.CO;2 Occurrence Handle1:STN:280:DyaK1c%2FnvFeqsw%3D%3D Occurrence Handle9418196

    Article  CAS  PubMed  Google Scholar 

  34. M Zanchetta G Rigatelli L Pedon et al. (2001) ArticleTitleAn unusual case of renal artery stenosis following endovascular AAA repair Eur J Vasc Endovasc Surg 21 379–380 Occurrence Handle10.1053/ejvs.2000.1289 Occurrence Handle1:STN:280:DC%2BD3M3nsFyksA%3D%3D Occurrence Handle11359343

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mario Zanchetta.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zanchetta, M., Rigatelli, G., Pedon, L. et al. Endovascular Repair of Complex Aortic Aneurysms: Intravascular Ultrasound Guidance with an Intracardiac Probe . CVIR 26, 448–453 (2003). https://doi.org/10.1007/s00270-003-0054-5

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00270-003-0054-5

Keywords

Navigation