Skip to main content
Log in

Wedged Hepatic Venography for Targeting the Portal Vein During TIPS: Comparison of Carbon Dioxide and Iodinated Contrast Agents

  • Published:
CardioVascular and Interventional Radiology Aims and scope Submit manuscript

Purpose: Carbon dioxide (CO2) can traverse the hepatic sinusoids better than iodinated contrast medium and has been used by many interventionalists for wedged hepatic venography during transjugular intrahepatic portosystemic shunt (TIPS) procedures. Our study was designed to compare the extent of the portal vein opacification using either CO2 or iodinated contrast medium. Methods: Wedged hepatic venography for portal vein opacification during TIPS was performed using hand injection through a 6.5 Fr diagnostic catheter. Portograms of 36 patients performed with 10 ml of iodinated contrast medium were retrospectively compared with portograms of 45 patients performed with 30-40 ml of CO2. Opacification of the right portal vein branch including the portal vein bifurcation was defined as a successful study. Results: Using CO2 the right portal vein branch and the portal vein bifurcation were opacified in 87% of patients (39 of 45); only a part of the right portal vein branch was opacified in 6% of patients and no opacification of any portal vein branch was seen in 7% of patients. Using iodinated contrast medium, there was opacification of the portal vein bifurcation in 25% of patients (9 of 36), of a part of the portal vein branch in 36% and no opacification of any branch in 39%. There was one case of hepatic laceration from CO2 wedged venography which was treated with microcoil embolization. Conclusions: Using CO2 as a contrast medium, opacification of the portal vein bifurcation by wedged hepatic venography was seen in 87% of patients, in comparison with only 25% when iodinated contrast medium was used (p < 0.001). CO2 is superior to iodinated contrast medium for wedged hepatic venography during TIPS.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Krajina, A., Lojik, M., Chovanec, V. et al. Wedged Hepatic Venography for Targeting the Portal Vein During TIPS: Comparison of Carbon Dioxide and Iodinated Contrast Agents. CVIR 25, 171–175 (2002). https://doi.org/10.1007/s00270-001-0096-5

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00270-001-0096-5

Keywords

Navigation