Skip to main content
Log in

Ultrasound-Guided Aspiration Biopsy for Detection of Nonpalpable Axillary Node Metastases in Breast Cancer Patients: New Diagnostic Method

  • Published:
World Journal of Surgery Aims and scope Submit manuscript

    We’re sorry, something doesn't seem to be working properly.

    Please try refreshing the page. If that doesn't work, please contact support so we can address the problem.

Abstract. This study was designed to evaluate the accuracy of ultrasonography alone and in combination with fine-needle aspiration biopsy (FNAB) for detection of axillary metastases of nonpalpable lymph nodes in breast cancer patients. Ultrasonography was carried out in 150 axillas of 148 patients (mean age 57 years, range 30–80 years); and in 93 axillas lymph nodes were detected. Nodes were described according to their dimension and echo patterns and were compared with histopathologic results. FNAB was carried out in 81 axillas (122 nodes). The sensitivity of ultrasonography was highest (87%) when size (length >5 mm) was used as criterion for malignancy, but the specificity was rather low (56%). When nodes with a malignant pattern (echo-poor or inhomogeneous) were visualized, specificity was 95%. Ultrasound-guided FNAB had a sensitivity of 80% and a specificity of 100% and detected metastases in 63% of node-positive patients. It is concluded that FNAB is an easy, reliable, inexpensive method for identifying patients with positive nodes. In the case of negative findings, other diagnostic procedures to exclude lymph node metastases, such as sentinel node mapping, could be performed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bonnema, J., van Geel, A., van Ooijen, B. et al. Ultrasound-Guided Aspiration Biopsy for Detection of Nonpalpable Axillary Node Metastases in Breast Cancer Patients: New Diagnostic Method. World J. Surg. 21, 270–274 (1997). https://doi.org/10.1007/s002689900227

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002689900227

Keywords

Navigation