Skip to main content
Log in

Echocardiographic and Clinical Follow-up After Aortic Valve Neocuspidization Using Autologous Pericardium

  • Original Scientific Report
  • Published:
World Journal of Surgery Aims and scope Submit manuscript

Abstract

Introduction

Mid-term data from a single centre showed the safety and durability of aortic valve neocuspidization using autologous pericardium (OZAKI procedure). Since validation data from other centres are missing, aim of this study was to analyze echocardiographic and clinical results of our first patients that were operated with the OZAKI technique.

Methods

Thirty-five patients (24 males, median (IQR) age 72.0 (59.0, 76.0) years) with aortic stenosis (AS; n = 10), aortic insufficiency (AR; n = 13) or a combination of both (AS/AR; n = 12), underwent aortic valve neocuspidization in our institution between September 2015 and May 2017. Echocardiographic follow-up was performed using a standardized examination protocol.

Results

Clinical follow-up was completed in 97% of the patients. Median (IQR) follow-up time was 645 (430, 813) days. Mortality rate was 9% (n = 1: aspiration pneumonia; n = 1: unknown; n = 1: anaphylactic shock), and the reoperation rate was 3% (n = 1: endocarditis). No pacemaker implantation was necessary after isolated OZAKI procedures. Echocardiographic follow-up was performed in 83% of the patients (n = 29; median (IQR) time 664 (497, 815) days). Median (IQR) mean and peak gradients were 6 (5,9) mmHg and 12 (8, 17) mmHg. Moderate aortic regurgitation was seen in 2 patients (7%). No severe aortic regurgitation or moderate or severe aortic stenosis occurred within the follow-up period.

Conclusions

The OZAKI procedure is reliable and reoperation due to structural valve deterioration nil within a median 645 days follow-up period. The low rate of moderate aortic regurgitation will be surveilled very closely. Further studies are required to evaluate the significance of this procedure in aortic valve surgery.

Clinical registration number

ClinicalTrials.gov (ID NCT03677804)

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Baumgartner H, Falk V, Bax JJ, De Bonis M, Hamm C, Holm PJ et al (2017 ) 2017 ESC/EACTS guidelines for the management of valvular heart disease. Eur Heart J 38(36):2739–2791

    Article  Google Scholar 

  2. Ozaki S, Kawase I, Yamashita H, Uchida S, Nozawa Y, Matsuyama T et al (2011) Aortic valve reconstruction using self-developed aortic valve plasty system in aortic valve disease. Interact Cardiovasc Thorac Surg 12(4):550–553

    Article  Google Scholar 

  3. Ozaki S, Kawase I, Yamashita H, Uchida S, Takatoh M, Hagiwara S et al (2015) Aortic valve reconstruction using autologous pericardium for aortic stenosis. Circ J 79(July):1504–1510

    Article  Google Scholar 

  4. Reuthebuch O, Koechlin L, Schurr U, Grapow M, Fassl J, Eckstein FS (2018) Aortic valve replacement using autologous pericardium: single centre experience with the Ozaki technique. Swiss Med Wkly 148:w14591

    PubMed  Google Scholar 

  5. Ozaki S, Kawase I, Yamashita H, Uchida S, Takatoh M, Kiyohara N (2018) Midterm outcomes after aortic valve neocuspidization with glutaraldehyde-treated autologous pericardium. J Thorac Cardiovasc Surg 155(6):2379–2387

    Article  Google Scholar 

  6. Sologashvili T, Prêtre R (2018) The place of the Ozaki procedure in the treatment of aortic valve disease. Swiss Med Wkly 148:w14612. https://doi.org/10.4414/smw.2018.14612

  7. Mourad F, Shehada SE, Lubarski J, Serrano M, Demircioglu E, Wendt D et al (2019) Aortic valve construction using pericardial tissue: Short-term single-centre outcomes †. Interact Cardiovasc Thorac Surg 28(2):183–190

    Article  Google Scholar 

Download references

Acknowledgements

The authors would like to thank Dr. Selina Ackermann for the critical review of the manuscript.

Funding

We have received no funding for this study.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Oliver Reuthebuch.

Ethics declarations

Conflict of interest

On behalf of all authors, the corresponding author states that there is no conflict of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Supplementary file1 (DOCX 41 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Koechlin, L., Schurr, U., Miazza, J. et al. Echocardiographic and Clinical Follow-up After Aortic Valve Neocuspidization Using Autologous Pericardium. World J Surg 44, 3175–3181 (2020). https://doi.org/10.1007/s00268-020-05588-x

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00268-020-05588-x

Navigation