Abstract
Background
Maintaining continuity of the greater trochanter and restoring abductor function are of paramount importance in primary and revision total hip arthroplasty. Failure to rigidly fix the greater trochanter can lead to failure. Because of the lack of reports on the clinical results of greater trochanter fixation with a claw plate and cable system, we aimed to analyze the indications for the use of such a system that produces the best clinical results.
Methods
We retrospectively studied 41 consecutive patients who had undergone primary or revision total hip arthroplasty at our institution between January 2004 and December 2014 using a claw plate and cable system to achieve stable fixation of the greater trochanter.
Results
The mean follow-up duration was ten years. The median Harris hip score improved from 47 points before surgery to 87 points after surgery (p < 0.01). Significant improvements were observed in the range of motion, hip function, and routine activity. Osseous and fibrous union occurred in all patients, and one patient had severe complications (sciatica). Based on the Beals and Tower classification, 67%, 21%, and 13% of outcomes were considered excellent, good, and poor, respectively.
Conclusions
Our data support the use of a claw plate and cable system for greater trochanter fixation in complex primary and revision hip arthroplasty. The system showed promising results in patients with floating greater trochanters, intertrochanteric fractures requiring extra devices to maintain rotational stability, and extended trochanteric osteotomy fragments with a weakened proximodistal junction. The use of this system should be further investigated and compared to other methods.
Similar content being viewed by others
Data availability
All data are available in Chinese.
References
Hamadouche M, Zniber B, Dumaine V, Kerboull M, Courpied JP (2004) Reattachment of the ununited greater trochanter following total hip arthroplasty. J Bone Joint Surg Am 86-A(Suppl 1):112–118. https://doi.org/10.2106/00004623-200409001-00002
Harris WH, Crothers OD (1978) Reattachment of the greater trochanter in total hip-replacement arthroplasty. A new technique. J Bone Joint Surg Am 60:211–213
Jensen NF, Harris WH (1986) A system for trochanteric osteotomy and reattachment for total hip arthroplasty with a ninety-nine percent union rate. Clin Orthop Relat Res:174–181
Nercessian OA, Newton PM, Joshi RP, Sheikh B, Eftekhar NS (1996) Trochanteric osteotomy and wire fixation: a comparison of 2 techniques. Clin Orthop Relat Res 333:208–216
Bal BS, Maurer BT, Harris WH (1998) Trochanteric union following revision total hip arthroplasty. J Arthroplasty 13:29–33. https://doi.org/10.1016/s0883-5403(98)90072-9
Bernard AA, Brooks S (1987) The role of trochanteric wire revision after total hip replacement. J Bone Joint Surg Br 69:352–354. https://doi.org/10.1302/0301-620X.69B3.3584183
Markolf KL, Hirschowitz DL, Amstutz HC (1979) Mechanical stability of the greater trochanter following osteotomy and reattachment by wiring. Clin Orthop Relat Res:111–121
Schutzer SF, Harris WH (1988) Trochanteric osteotomy for revision total hip arthroplasty. 97% union rate using a comprehensive approach. Clin Orthop Relat Res 227:172–183
Mei XY, Gong YJ, Safir OA, Gross AE, Kuzyk PR (2018) Fixation options following greater trochanteric osteotomies and fractures in total hip arthroplasty: a systematic review. JBJS Rev 6:e4. https://doi.org/10.2106/JBJS.RVW.17.00164
Zhu Z, Ding H, Shao H, Zhou Y, Wang G (2013) An in-vitro biomechanical study of different fixation techniques for the extended trochanteric osteotomy in revision THA. J Orthop Surg Res 8:7. https://doi.org/10.1186/1749-799X-8-7
Hersh CK, Williams RP, Trick LW, Lanctot D, Athanasiou K (1996) Comparison of the mechanical performance of trochanteric fixation devices. Clin Orthop Relat Res:317–325. https://doi.org/10.1097/00003086-199608000-00039
Wroblewski BM, Shelley P (1985) Reattachment of the greater trochanter after hip replacement. J Bone Joint Surg Br 67:736–740. https://doi.org/10.1302/0301-620X.67B5.4055872
Abdel MP, Cottino U, Mabry TM (2015) Management of periprosthetic femoral fractures following total hip arthroplasty: a review. Int Orthop 39:2005–2010. https://doi.org/10.1007/s00264-015-2979-0
Altenburg AJ, Callaghan JJ, Yehyawi TM, Pedersen DR, Liu SS, Leinen JA, Dahl KA, Goetz DD, Brown TD, Johnston RC (2009) Cemented total hip replacement cable debris and acetabular construct durability. J Bone Joint Surg Am 91:1664–1670. https://doi.org/10.2106/JBJS.G.00428
Hamadouche M, Zniber B, Dumaine V, Kerboull M, Courpied JP (2003) Reattachment of the ununited greater trochanter following total hip arthroplasty. The use of a trochanteric claw plate. J Bone Joint Surg Am 85:1330–1337. https://doi.org/10.2106/00004623-200307000-00020
Kim IS, Pansey N, Kansay RK, Yoo JH, Lee HY, Chang JD (2017) Greater trochanteric reattachment using the third-generation cable plate system in revision total hip arthroplasty. J Arthroplasty 32:1965–1969. https://doi.org/10.1016/j.arth.2017.01.017
Dall DM, Miles AW (1983) Re-attachment of the greater trochanter. The use of the trochanter cable-grip system. J Bone Joint Surg Br 65:55–59. https://doi.org/10.1302/0301-620X.65B1.6337168
Jarit GJ, Sathappan SS, Panchal A, Strauss E, Di Cesare PE (2007) Fixation systems of greater trochanteric osteotomies: biomechanical and clinical outcomes. J Am Acad Orthop Surg 15:614–624. https://doi.org/10.5435/00124635-200710000-00006
Malahias MA, Gkiatas I, Selemon NA, De Filippis R, Gu A, Greenberg A, Sculco PK (2020) Outcomes and risk factors of extended trochanteric osteotomy in aseptic revision total hip arthroplasty: a systematic review. J Arthroplasty 35:3410–3416. https://doi.org/10.1016/j.arth.2020.07.034
Sheridan GA, Galbraith A, Kearns SR, Curtin W, Murphy CG (2018) Extended trochanteric osteotomy (ETO) fixation for femoral stem revision in periprosthetic fractures: Dall-Miles plate versus cables. Eur J Orthop Surg Traumatol 28:471–476. https://doi.org/10.1007/s00590-017-2064-z
Hodgkinson JP, Shelley P, Wroblewski BM (1989) Re-attachment of the un-united trochanter in Charnley low friction arthroplasty. J Bone Joint Surg Br 71:523–525. https://doi.org/10.1302/0301-620X.71B3.2722950
Zarin JS, Zurakowski D, Burke DW (2009) Claw plate fixation of the greater trochanter in revision total hip arthroplasty. J Arthroplasty 24:272–280. https://doi.org/10.1016/j.arth.2007.09.016
Tsiridis E, Haddad FS, Gie GA (2003) Dall-Miles plates for periprosthetic femoral fractures. A critical review of 16 cases. Injury 34:107–110. https://doi.org/10.1016/s0020-1383(02)00161-4
McCarthy JC, Bono JV, Turner RH, Kremchek T, Lee J (1999) The outcome of trochanteric reattachment in revision total hip arthroplasty with a cable grip system: mean 6-year follow-up. J Arthroplasty 14:810–814. https://doi.org/10.1016/s0883-5403(99)90030-x
Acknowledgements
We would like to thank Editage for English language editing.
Author information
Authors and Affiliations
Contributions
Jing Tang, M.D. (conceptualization; data curation; formal analysis; investigation; methodology; project administration; software; writing—original draft; writing—review and editing).
Tiemure Wu, M.D. (conceptualization; data curation; formal analysis; investigation; methodology; project administration; software; writing—original draft; writing—review and editing).
Hongyi Shao, M.D. (investigation; methodology; resources; writing—review and editing).
Yixin Zhou, MD, PhD (conceptualization; formal analysis; methodology; project administration; resources; supervision; validation; visualization; writing—review and editing).
Corresponding author
Ethics declarations
Ethics approval
The study design was approved by the appropriate ethics review board.
Consent to participate
All the patients have signed the informed consent.
Consent for publication
All authors have participated in conducting the research study and have consented to submit this paper. This manuscript has not been published or presented elsewhere in part or in entirety and is not under consideration by another journal.
Conflict of interest
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Tang, J., Wu, T., Shao, H. et al. Greater trochanter fixed with a claw plate and cable system in complex primary and revision total hip arthroplasty: long-term follow-up. International Orthopaedics (SICOT) 46, 2553–2560 (2022). https://doi.org/10.1007/s00264-022-05538-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-022-05538-3