Abstract
Purpose
The study compared the impact of the Kirschner wires versus Herbert screw fixation on the rate of union, time to union, correction of deformity, and clinical outcome in adults with unstable scaphoid waist fracture nonunions without avascular necrosis.
Methods
We prospectively randomized 122 patients to undergo corticocancellous iliac bone grafting and internal fixation either with multiple Kirschner wires or Herbert screw. Radiographs, clinical outcome measures (pain, range of motion, and grip strength), and the Quick DASH score were taken pre- and post-operatively.
Results
The rate of the scaphoid union in the Kirschner wire group was 91% versus 88% in the Herbert group. No difference was detected between the two groups with respect to the time to union, deformity correction, pain analysis, range of motion, grip strength, return to work, and complications.
Conclusion
Using of multiple Kirschner wires as a fixation method for unstable scaphoid waist fracture nonunion that was treated by open reduction and corticocancellous iliac bone grafting had a shorter operative time and lower cost as compared with the Herbert screw fixation. Herbert screw fixation was technically more demanding in terms of technique than K-wires. However, because of easy application of Kirschner wires, and low cost, especially in developing countries, it may be a good alternative to Herbert screw.
Similar content being viewed by others
References
Kawamura K, Chung KC (2008) Treatment of scaphoid fractures and nonunions. J Hand Surg Am 33:988–997. https://doi.org/10.1016/j.jhsa.2008.04.026
Leyshon A, Ireland J, Trickey EL (1984) The treatment of delayed union and non-union of the carpal scaphoid by screw fixation. J Bone Joint Surg Br 66:124–127
Merrell GA, Wolfe SW, Slade JF III (2002) Treatment of scaphoid nonunions: quantitative meta-analysis of the literature. J Hand Surg Am 27:685–691. https://doi.org/10.1053/jhsu.2002.34372
Gupta A, Risitano G, Crawford RJ, Burke FD (1999) The ununited scaphoid: prognostic factors in delayed and nonunions of the scaphoid. Hand Surg 4:11–19. https://doi.org/10.1142/S0218810499000101
Fernandez DL (1984) A technique for anterior wedge-shaped grafts for scaphoid nonunions with carpal instability. J Hand Surg Am 9:733–737. https://doi.org/10.1016/S0363-5023(84)80025-8
Herbert TJ, Fisher WE (1984) Management of the fractured scaphoid using a new bone screw. J Bone Joint Surg Br 66:114–123
Linscheid RL, Dobyns JH, Beabout JW, Bryan RS (1972) Traumatic instability of the wrist: diagnosis, classification, and pathomechanics. J Bone Joint Surg Am 54:1612–1632
Amadio PC, Berquist TH, Smith DK, Ilstrup DM, Cooney WP III, Linscheid RL (1989) Scaphoid malunion. J Hand Surg Am 14:679–687. https://doi.org/10.1016/0363-5023(89)90191-3
Hudak PL, Amadio PC, Bombardier C (1996) Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand). The Upper Extremity Collaborative Group (UECG). Am J Ind Med 29:602–608. https://doi.org/10.1002/(SICI)1097-0274(199606)29:6<602::AID-AJIM4>3.0.CO;2-L
Jensen MP, Chen C, Brugger AM (2003) Interpretation of visual analogue scale ratings and change scores: a reanalysis of two clinical trials of post-operative pain. J Pain 4:407–414. https://doi.org/10.1016/S1526-5900(03)00716-8
Carter TI, Pansy B, Wolff AL, Hillstrom HJ, Backus SI, Lenhoff M, Wolfe SW (2009) Accuracy and reliability of three different techniques for manual goniometry for wrist motion: a cadaveric study. J Hand Surg Am 34:1422–1428. https://doi.org/10.1016/j.jhsa.2009.06.002
Roberts HC, Denison HJ, Martin HJ, Patel HP, Syddall H, Cooper C, Sayer AA (2011) A review of the measurement of grip strength in clinical and epidemiological studies: towards a standardised approach. Age Ageing 40:423–429. https://doi.org/10.1093/ageing/afr051
Tang JB, Giddins G (2016) Why and how to report surgeons’ levels of expertise. J Hand Surg Eur 41:365–366. https://doi.org/10.1177/1753193416641590
Youm Y, McMurthy RY, Flatt AE, Gillespie TE (1978) Kinematics of the wrist. An experimental study of radial-ulnar deviation and flexion-extension. J Bone Joint Surg Am 60:423–431
Clay NR, Dias JJ, Costigan PS, Gregg PJ, Barton NJ (1991) Need the thumb be immobilised in scaphoid fractures? A randomised prospective trial. J Bone Joint Surg Br 73:828–832
Jarrett P, Kinzel V, Stoffel K (2007) A biomechanical comparison of scaphoid fixation with bone grafting using iliac bone or distal radius bone. J Hand Surg Am 32:1367–1373. https://doi.org/10.1016/j.jhsa.2007.06.009
Park H, Yoon J, Jeon I, Chung H, Kim J (2013) A comparison of the rates of union after cancellous iliac crest bone graft and Kirschner-wire fixation in the treatment of stable and unstable scaphoid nonunion. Bone Joint J 95:809–814. https://doi.org/10.1302/0301-620X.95B6.31259
Kirkham SG, Millar MJ (2012) Cancellous bone graft and Kirschner wire fixation as a treatment for cavitary-type scaphoid nonunions exhibiting DISI. Hand 7:86–93. https://doi.org/10.1007/s11552-011-9375-z
Stark HH, Rickard TA, Zemel NP, Ashworth CR (1988) Treatment of ununited fractures of the scaphoid by iliac bone grafts and Kirschner wire fixation. J Bone Joint Surg Am 70:982–991
Yasuda M, Ando Y, Masada K (2007) Treatment of scaphoid nonunion using volar biconcave cancellous bone grafting. Hand Surg 12:135–140. https://doi.org/10.1142/S0218810407003468
Luria S, Hoch S, Liebergall M, Mosheiff R, Peleg E (2010) Optimal fixation of acute scaphoid fractures: finite element analysis. J Hand Surg 35:1246–1250. https://doi.org/10.1016/j.jhsa.2010.05.011
Meisel E, Seal A, Yao CA, Ghiassi A, Stevanovic M (2017) Management of scaphoid nonunion with iliac crest bone graft and K-wire fixation. Eur J Orthop Surg Traumatol 27:23–31. https://doi.org/10.1007/s00590-016-1876-6
Munk B, Larsen CF (2004) Bone grafting the scaphoid nonunion: a systematic review of 147 publications including 5,246 cases of scaphoid nonunion. Acta Orthop Scand 75:618–629. https://doi.org/10.1080/00016470410001529
Reigstad O, Thorkildsen R, Grimsgaard C, Reigstad A, Rokkum M (2010) Healing of ununited scaphoid fractures by Kirschner wires and autologous structural bone grafts. Scand J Plast Reconstr Surg Hand Surg 44:106–111. https://doi.org/10.3109/02844310903528663
Takami H, Takahashi S, Ando M (2000) Scaphoid nonunion treated by open reduction, anterior inlay bone grafting, and Kirschner-wire fixation. Arch Orthop Trauma Surg 120:134–138. https://doi.org/10.1007/pl00013760
Ritter K, Giachino AA (2000) The treatment of pseudoarthrosis of the scaphoid by bone grafting and three methods of internal fixation. Can J Surg 43:118–124
Chen CY, Chao EK, Lee SS, Ueng SW (1999) Osteosynthesis of carpal scaphoid nonunion with interpositional bone graft and Kirschner wires: a 3- to 6-year follow-up. J Trauma 47:558–563. https://doi.org/10.1097/00005373-199909000-00024
Petcu I (1998) Treatment of scaphoid nonunions by Russe bone grafting-a retrospective analysis. Rev Med Chir Soc Med Nat Iasi 102:105–114
Watanabe K (2011) Analysis of carpal malalignment caused by scaphoid nonunion and evaluation of corrective bone graft on carpal alignment. J. Hand Surg Am 36:10–16. https://doi.org/10.1016/j.jhsa.2010.10.011
Wada T, Aoki M, Usui M, Ishii S (1999) DISI deformity and post-operative symptoms of scaphoid non-union. Hand Surg 4:117–124. https://doi.org/10.1142/s0218810499000393
Inoue G, Shionoya K, Kuwahata Y (1997) Herbert screw fixation for scaphoid nonunions: an analysis of factors influencing outcome. Clin Orthop Relat Res 343:99–106
Trumble TE, Clarke T, Kreder HJ (1996) Nonunion of the scaphoid, treatment with cannulated screws compared with treatment with Herbert screws. J Bone Joint Surg Am 78:1829–1837. https://doi.org/10.2106/00004623-199612000-00005
Nakamura R, Imaeda T, Tsuge S, Watanabe K (1991) Scaphoid non-union with DISI deformity: a survey of clinical cases with special reference to ligamentous injury. J Hand Surg Br 16:156–161. https://doi.org/10.1016/0266-7681(91)90167-m
Adams BD, Blair WF, Reagan DS, Grundberg AB (1988) Technical factors related to Herbert screw fixation. J Hand Surg Am 13:893–899. https://doi.org/10.1016/0363-5023(88)90267-5
Acknowledgments
We wish to acknowledge the help and guidance provided by our Professors, Ahmed Shamma, Ibrahim Mustaffa, Mohamed Bessar, Ali Algushy, and Ismail Yassin, the members of the ethics committee of the Orthopedic department–Faculty of Medicine–Al-Azhar University–Cairo Egypt.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical considerations
Our institutional review board approved this retrospective study before commencement.
Consent
All patients were given an information sheet; the risks and benefits of operative treatment were discussed and full written consent was obtained.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Level of evidence: I
Rights and permissions
About this article
Cite this article
Hegazy, G., Alshal, E., Abdelaal, M. et al. Kirschner wire versus Herbert screw fixation for the treatment of unstable scaphoid waist fracture nonunion using corticocancellous iliac bone graft: randomized clinical trial. International Orthopaedics (SICOT) 44, 2385–2393 (2020). https://doi.org/10.1007/s00264-020-04730-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-020-04730-7