Abstract
Purpose
Cementless acetabular fixation for total hip arthroplasty (THA) is widely used. The question of using screws for a better primary and secondary acetabular fixation has been discussed in the literature in recent years. The aim of this meta-analysis was to compare fixation of acetabular cups with and without screws in total hip arthroplasty.
Methods
Electronic databases Embase, PubMed and Cochrane Library were used to search for randomised controlled trials reported through May 2013 of cementless acetabular fixation for THA with and without screws. Two independent reviewers assessed the trials for eligibility and quality. All related data matching our standards were abstracted for meta-analysis by RevMan 5.0. Evaluation criteria included revisions, migration and osteolysis.
Results
A total of 1,130 THAs enrolled into five trials were included in this meta-analysis. All studies compared fixation of acetabular cups with and without screws, and our pooled data showed no statistical significance between the two surgical methods in revision, migration and osteolysis.
Conclusion
There is no significant difference between cementless acetabular fixation for THA with and without screws in revisions, migration or osteolysis.
Similar content being viewed by others
References
Mulroy RD Jr, Harris WH (1990) The effect of improved cementing techniques on component loosening in total hip replacement. An 11-year radiographic review. J Bone Joint Surg Br 72(5):757–760
Wroblewski BM (1988) Wear and loosening of the socket in the Charnley low-friction arthroplasty. Orthop Clin North Am 19(3):627–630
Pulido L, Rachala SR, Cabanela ME (2011) Cementless acetabular revision: past, present, and future. Revision total hip arthroplasty: the acetabular side using cementless implants. Int Orthop 35(2):289–298
Sadoghi P, Janda W, Agreiter M, Rauf R, Leithner A, Labek G (2013) Pooled outcome of total hip arthroplasty with the CementLess Spotorno (CLS) system: a comparative analysis of clinical studies and worldwide arthroplasty register data. Int Orthop 37(6):995–999
Yamada H, Yoshihara Y, Henmi O, Morita M, Shiromoto Y, Kawano T, Kanaji A, Ando K, Nakagawa M, Kosaki N, Fukaya E (2009) Cementless total hip replacement: past, present, and future. J Orthop Sci 14(2):228–241
Litsky AS, Pophal SG (1994) Initial mechanical stability of acetabular prostheses. Orthopedics 17(1):53–57
Schwartz JT Jr, Engh CA, Forte MR, Kukita Y, Grandia SK (1993) Evaluation of initial surface apposition in porous-coated acetabular components. Clin Orthop Relat Res 293:174–187
Szmukler-Moncler S, Salama H, Reingewirtz Y, Dubruille JH (1998) Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. J Biomed Mater Res 43(2):192–203
Udomkiat P, Dorr LD, Wan Z (2002) Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up. J Bone Joint Surg Am 84-A(7):1195–1200
Hsu JT, Chang CH, Huang HL, Zobitz ME, Chen WP, Lai KA, An KN (2007) The number of screws, bone quality, and friction coefficient affect acetabular cup stability. Med Eng Phys 29(10):1089–1095
Higgins JPT, Green S (eds) (2008) Cochrane handbook for systematic reviews of interventions version 5.0.1. Chichester, United Kingdom: The cochrane collaboration; 2008. Available at: http://www.cochrane-handbook.org
Iorio R, Puskas B, Healy WL, Tilzey JF, Specht LM, Thompson MS (2010) Cementless acetabular fixation with and without screws: analysis of stability and migration. J Arthroplasty 25(2):309–313
Pakvis D, Luites J, van Hellemondt G, Spruit M (2012) A cementless, elastic press-fit socket with and without screws. Acta Orthop 83(5):481–487
Röhrl SM, Nivbrant B, Ström H, Nilsson KG (2004) Effect of augmented cup fixation on stability, wear, and osteolysis: a 5-year follow-up of total hip arthroplasty with RSA. J Arthroplasty 19(8):962–971
Roth A, Winzer T, Sander K, Anders JO, Venbrocks RA (2006) Press fit fixation of cementless cups: how much stability do we need indeed? Arch Orthop Trauma Surg 126(2):77–81
Thanner J, Kärrholm J, Herberts P, Malchau H (2000) Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation: a randomized study of 64 hips. J Arthroplasty 15(4):405–412
Pilliar RM, Lee JM, Maniatopoulos C (1986) Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop Relat Res (208):108–113
Lachiewicz PF, Suh PB, Gilbert JA (1989) In vitro initial fixation of porous-coated acetabular total hip components. A biomechanical comparative study. J Arthroplasty 4(3):201–205
Wasielewski RC, Cooperstein LA, Kruger MP, Rubash HE (1990) Acetabular anatomy and the transacetabular fixation of screws in total hip arthroplasty. J Bone Joint Surg Am 72(4):501–508
Schmalzried TP, Akizuki KH, Fedenko AN, Mirra J (1997) The role of access of joint fluid to bone in periarticular osteolysis. A report of four cases. J Bone Joint Surg Am 79(3):447–452
Synder M, Drobniewski M, Sibiński M (2012) Long-term results of cementless hip arthroplasty with ceramic-on-ceramic articulation. Int Orthop 36(11):2225–2229
Acknowledgments
We are thankful to China Medical University-affiliated Hospital Laboratory Centre for kindly providing the necessary equipment for this study. This work was supported by the National Natural Science Foundation of China (grant numbers 30872724, 81071460, and 81271996), the Natural Science Foundation of Liaoning Province (grant number 201202292).
Declaration of interests
The authors declare no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ni, SH., Guo, L., Jiang, TL. et al. Press-fit cementless acetabular fixation with and without screws. International Orthopaedics (SICOT) 38, 7–12 (2014). https://doi.org/10.1007/s00264-013-2075-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-013-2075-2