Abstract
The aim of this paper is to review recent experimental and clinical publications on bone biology with respect to the optimal mechanical environment in the healing process of fractures and osteotomies. The basic postulates of bone fracture healing include static bone compression and immobilisation/fixation for three weeks and intermittent dynamic loading treatment afterwards. The optimal mechanical strain should be in the range of 100–2,000 microstrain, depending on the frequency of the strain application, type of bone and location in the bone, age and hormonal status. Higher frequency of mechanical strain application or larger number of repetition cycles result in increased bone mass at the healing fracture site, but only up to a certain limit, values beyond which no additional benefit is observed. Strain application and transition period from non-load-bearing to full load-bearing can be modified by implants allowing dynamisation of compression and generating strains at the fracture healing site in a controlled manner.
Similar content being viewed by others
References
Wood GW (2007) Fractures and dislocation, general principles of fracture treatment. In: Canale ST, Beaty JH (eds) Campbell’s operative orthopaedics, 11th edn. Mosby, Philadelphia, pp 3018–3085
Rüedi TP, Buckley RE, Moran CG (2007) AO principles of fracture management. Thieme, New York
Wolff J (2011) The classic: on the significance of the architecture of the spongy substance for the question of bone growth: a preliminary publication. 1869. Clin Orthop Relat Res 469:3077–3078. doi:10.1007/s11999-011-2041-5
Lanyon LE (1974) Experimental support for the trajectorial theory of bone structure. J Bone Joint Surg Br 56:160–166
Lanyon LE, Baggott DG (1976) Mechanical function as an influence on the structure and form of bone. J Bone Joint Surg Br 58-B:436–443
Woo SL, Kuei SC, Amiel D, Gomez MA, Hayes WC, White FC, Akeson WH (1981) The effect of prolonged physical training on the properties of long bone: a study of Wolff’s Law. J Bone Joint Surg Am 63:780–787
McKibbin B (1978) The biology of fracture healing in long bones. J Bone Joint Surg Br 60-B:150–162
Baggott DG, Goodship AE, Lanyon LE (1981) A quantitative assessment of compression plate fixation in vivo: an experimental study using the sheep radius. J Biomech 14:701–711
Chao EY, Kasman RA, An KN (1982) Rigidity and stress analyses of external fracture fixation devices–a theoretical approach. J Biomech 15:971–983
Lewallen DG, Chao EY, Kasman RA, Kelly PJ (1984) Comparison of the effects of compression plates and external fixators on early bone-healing. J Bone Joint Surg Am 66:1084–1091
Terjesen T (1984) Bone healing after metal plate fixation and external fixation of the osteotomized rabbit tibia. Acta Orthop Scand 55:69–77
Cheal EJ, Hayes WC, White AA 3rd, Perren SM (1985) Stress analysis of compression plate fixation and its effects on long bone remodeling. J Biomech 18:141–150
Court-Brown CM (1985) The effect of external skeletal fixation on bone healing and bone blood supply. An experimental study. Clin Orthop Relat Res 201:278–289
Hart MB, Wu JJ, Chao EY, Kelly PJ (1985) External skeletal fixation of canine tibial osteotomies. Compression compared with no compression. J Bone Joint Surg Am 67:598–605
Holmström T, Paavolainen P, Slätis P, Karaharju E (1986) Effect of compression on fracture healing. Plate fixation studied in rabbits. Acta Orthop Scand 57:368–372
De Bastiani G, Aldegheri R, Renzi Brivio L (1986) Dynamic axial fixation. A rational alternative for the external fixation of fractures. Int Orthop 10:95–99
Aalto K, Holmström T, Karaharju E, Joukainen J, Paavolainen P, Slätis P (1987) Fracture repair during external fixation. Torsion tests of rabbit osteotomies. Acta Orthop Scand 58:66–70
Kunnamo I (2005) Evidence-based medicine guidelines. Wiley, Chichester
Handoll HH, Parker MJ, Sherrington C (2003) Mobilisation strategies after hip fracture surgery in adults. Cochrane Database Syst Rev 1:CD001704
Skerry TM (2008) The response of bone to mechanical loading and disuse: fundamental principles and influences on osteoblast/osteocyte homeostasis. Arch Biochem Biophys 473:117–123
Marino AA, Becker RO (1970) Piezoelectric effect and growth control in bone. Nature 228:473–474. doi:10.1038/228473a0
Ciombor DM, Aaron RK (2005) The role of electrical stimulation in bone repair. Foot Ankle Clin 10:579–593
Frost HM (2004) A 2003 update of bone physiology and Wolff’s Law for clinicians. Angle Orthod 74:3–15
Ehrlich PJ, Lanyon LE (2002) Mechanical strain and bone cell function: a review. Osteoporos Int 13:688–700
Liedert A, Kaspar D, Augat P, Ignatius A, Claes L (2005) Mechanobiology of bone tissue and bone cells. In: Kamkin A, Kiseleva I (eds) Mechanosensitivity in cells and tissues. Academia, Moscow
Lee K, Jessop H, Suswillo R, Zaman G, Lanyon L (2003) Bone adaptation requires oestrogen receptor-alpha. Nature 424:389
Sutherland MK, Hui DU, Rao LG, Wylie JN, Murray TM (1996) Immunohistochemical localization of the estrogen receptor in human osteoblastic SaOS-2 cells: association of receptor levels with alkaline phosphatase activity. Bone 18:361–369
Sawakami K, Robling AG, Ai M, Pitner ND, Liu D, Warden SJ, Li J, Maye P, Rowe DW, Duncan RL, Warman ML, Turner CH (2006) The Wnt co-receptor LRP5 is essential for skeletal mechanotransduction but not for the anabolic bone response to parathyroid hormone treatment. J Biol Chem 281:23698–23711
Saxon LK, Jackson BF, Sugiyama T, Lanyon LE, Price JS (2011) Analysis of multiple bone responses to graded strains above functional levels, and to disuse, in mice in vivo show that the human Lrp5 G171V high bone mass mutation increases the osteogenic response to loading but that lack of Lrp5 activity reduces it. Bone 49:184–193
Jee WSS (2001) Integrated bone tissue physiology: anatomy and physiology. In: Cowin SC (ed) Bone mechanics handbook, 2nd edn. CRC, Boca Raton, pp 1–68
Meyer U, Meyer T, Wiesmann HP (1999) The effect of magnitude and frequency of interfragmentary strain on the tissue response to distraction osteogenesis. J Oral Maxillofac Surg 57:1331–1339
Frost HM, Meyer U, Joos U, Jensen OT (2002) Dental alveolar distraction osteogenesis and the Utah paradigm. In: Jensen OT (ed) Alveolar distraction osteogenesis. Quintessence, Carol Stream, pp 1–16
Fritton SP, Rubin CT (2001) In vivo measurement of bone deformations using strain gauges. In: Cowin SC (ed) Bone mechanics handbook, 2nd edn. CRC, Boca Raton, pp 8–34
Rubin CT, Turner AS, Bain S, Mallinckrodt C, McLeod K (2001) Anabolism. Low mechanical signals strengthen long bones. Nature 412:603–604
Rubin CT, Xu G, Judex S (2001) The anabolic activity of bone tissue, suppressed by disuse, is normalized by brief exposure to extremely low-magnitude mechanical stimuli. FASEB J 15:2225–2229
Rubin CT, Turner AS, Müller R, Mittra E, McLeod K, Lin W, Qin YX (2002) Quantity and quality of trabecular bone in the femur are enhanced by a strongly anabolic, noninvasive mechanical intervention. J Bone Miner Res 17:349–357
Churches AE, Howlett CR, Waldron KJ, Ward GW (1979) The response of living bone to controlled time-varying loading: method and preliminary results. J Biomech 12:35–45
Lanyon LE, Paul IL, Rubin CT, Thrasher EL, DeLaura R, Rose RM, Radin EL (1981) In vivo strain measurements from bone and prosthesis following total hip replacement. An experimental study in sheep. J Bone Joint Surg Am 63:989–1001
Churches AE, Howlett CR (1982) Functional adaptation of bone in response to sinusoidally varying controlled compressive loading of the ovine metacarpus. Clin Orthop Relat Res 168:265–280
O’Connor JA, Lanyon LE, MacFie H (1982) The influence of strain rate on adaptive bone remodelling. J Biomech 15:767–781
Rubin CT, Lanyon LE (1984) Regulation of bone formation by applied dynamic loads. J Bone Joint Surg Am 66:397–402
Lanyon LE, Rubin CT (1984) Static vs dynamic loads as an influence on bone remodelling. J Biomech 17:897–905
Rubin CT, Lanyon LE (1985) Regulation of bone mass by mechanical strain magnitude. Calcif Tissue Int 37:411–417
Lanyon LE, Rubin CT, Baust G (1986) Modulation of bone loss during calcium insufficiency by controlled dynamic loading. Calcif Tissue Int 38:209–216
Panjabi MM, White AA 3rd, Wolf JW Jr (1979) A biomechanical comparison of the effects of constant and cyclic compression on fracture healing in rabbit long bones. Acta Orthop Scand 50:653–661
Wolf JW Jr, White AA 3rd, Panjabi MM, Southwick WO (1981) Comparison of cyclic loading versus constant compression in the treatment of long-bone fractures in rabbits. J Bone Joint Surg Am 63:805–810
Carter DR (1984) Mechanical loading histories and cortical bone remodeling. Calcif Tissue Int 36(Suppl):S19–S24
Kempf I, Leung K, Grosse A (2002) Practice of intramedullary locked nails: scientific basis and standard techniques. Springer, Berlin, pp 47–48
Judex S, Rubin CT (2010) Is bone formation induced by high-frequency mechanical signals modulated by muscle activity? J Musculoskelet Neuronal Interact 10:3–11
Conflict of interest
The authors declare that they have no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Mavčič, B., Antolič, V. Optimal mechanical environment of the healing bone fracture/osteotomy. International Orthopaedics (SICOT) 36, 689–695 (2012). https://doi.org/10.1007/s00264-012-1487-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-012-1487-8