Abstract
In a prospective and randomised clinical study, we implanted acetabular cups either by means of an image-free computer-navigation system (navigated group, n = 32) or by free-hand technique (freehand group n = 32, two drop-outs). Total hip replacement was conducted in the lateral position and through a minimally invasive anterior approach (MicroHip). The position of the component was determined postoperatively on CT scans of the pelvis using CT-planning software. We found an average inclination of 42.3° (range 32.7–50.6°; SD±3.8°) and an average anteversion of 24.5° (range 12.0–33.3°; SD±6.0°) in the computer-assisted study group and an average inclination of 37.9° (range 25.6–50.2°; SD±6.3°) and an average anteversion of 23.8° (range 5.6–46.9°; SD±10.1°) in the freehand group. The higher precision of computer navigation was indicated by the lower standard deviations. For both measurements we found a significant heterogeneity of variances (p < 0.05, Levene's test). The mean difference between the cup inclination/anteversion values displayed by computer navigation and the true cup position (CT control) was 0.37° (SD 3.26) and −5.61° (SD 6.48), respectively. We found a bias (underestimation) with regard to anteversion determined by the imageless computer navigation system. A bias for inclination was not found. Registration of the landmarks of the anterior pelvic plane in lateral position with undraped percutaneous methods leads to an error in cup anteversion, but not to an error in cup inclination. The bias we found is consistent with a correct registration of the anterosuperior iliac spine (ASIS) and with a registration of the symphysis 1 cm above the bone, corresponding to the less compressible overlying soft tissue in this region. There was no significant correlation between the bias and the thickness of soft tissue above the pubic tubercles. We suggest use of a percutaneous registration of ASIS and an invasive registration above the pubic tubercles when computer-assisted navigation is performed in minimally invasive THR in a lateral position.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.References
Jolles BM, Genoud P, Hoffmeyer P (2004) Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement. Clin Orthop Relat Res 426:174–179
Nogler M, Kessler O, Prassl A, Donnelly B, Streicher R, Sledge JB, Krismer M (2004) Reduced variability of acetabular cup positioning with use of an imageless navigation system. Clin Orthop Relat Res 426:159–163
Kalteis T, Handel M, Bathis H, Perlick L, Tingart M, Grifka J (2006) Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation? J Bone Joint Surg Br 88:163–167
Gandhi R, Marchie A, Farrokhyar F, Mahomed N (2009) Computer navigation in total hip replacement: a meta-analysis. Int Orthop 33(3):593–597
Dorr LD, Malik A, Wan Z, Long WT, Harris M (2007) Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position. Clin Orthop Relat Res 465:92–99
McCollum DE, Gray WJ (1990) Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop Relat Res 261:159–170
Woolson ST, Mow CS, Syquia JF, Lannin JV, Schurman DJ (2004) Comparison of primary total hip replacements performed with a standard incision or a mini-incision. J Bone Joint Surg Am 86-A(7):1353–1358
Michel MC, Witschger P (2007) MicroHip: a minimally invasive procedure for total hip replacement surgery using a modified Smith-Peterson approach. Ortop Traumatol Rehabil 9(1):46–51
Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60:217–220
Murray DW (1993) The definition and measurement of acetabular orientation. J Bone Joint Surg Br 75-B:228–232
Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310
Learmonth ID, Young C, Rorabeck C (2007) The operation of the century: total hip replacement. Lancet 370(9597):1508–1519
Saxler G, Marx A, Vandevelde D, Langlotz U, Tannast M, Wiese M, Michaelis U, Kemper G, Grützner PA, Steffen R, von Knoch M, Holland-Letz T, Bernsmann K (2004) Cup placement in hip replacement surgery—a comparison of free-hand and computer assisted cup placement in total hip arthroplasty—a multi-center study. Z Orthop Ihre Grenzgeb 142(3):286–291
Ybinger T, Kumpan W (2007) Enhanced acetabular component positioning through computer-assisted navigation. Int Orthop 31(Suppl 1):S35–S38
Wixson RL, MacDonald MA (2005) Total hip arthroplasty through a minimal posterior approach using imageless computer-assisted hip navigation. J Arthroplasty 20(7 Suppl 3):51–56
DiGioia AM 3rd, Plakseychuk AY, Levison TJ, Jaramaz B (2003) Mini-incision technique for total hip arthroplasty with navigation. J Arthroplasty 18(2):123–128
Wixson RL (2008) Computer-assisted total hip navigation. Instr Course Lect 57:707–720
Parratte S, Kilian P, Pauly V, Champsaur P, Argenson JN (2008) The use of ultrasound in acquisition of the anterior pelvic plane in computer-assisted total hip replacement: a cadaver study. J Bone Joint Surg Br 90(2):258–263
Lee YS, Yoon TR (2008) Error in acetabular socket alignment due to the thick anterior pelvic soft tissues. J Arthroplasty 23(5):699–706
Babisch JW, Layher F, Amiot LP (2008) The rationale for tilt-adjusted acetabular cup navigation. J Bone Joint Surg Am 90(2):357–365
Dorr LD, Malik A, Dastane M, Wan Z (2009) Combined anteversion technique for total hip arthroplasty. Clin Orthop Relat Res 467(1):119–127
Renkawitz T, Tingart M, Grifka J, Sendtner E, Kalteis T (2009) Computer-assisted total hip arthroplasty: coding the next generation of navigation systems for orthopedic surgery. Expert Rev Med Devices 6(5):507–514
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Sendtner, E., Schuster, T., Wörner, M. et al. Accuracy of acetabular cup placement in computer-assisted, minimally-invasive THR in a lateral decubitus position. International Orthopaedics (SICOT) 35, 809–815 (2011). https://doi.org/10.1007/s00264-010-1042-4
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-010-1042-4