Abstract
The aim of this study was to determine whether there is a difference in functional outcome between the PFC Sigma fixed-bearing and rotating-platform total knee replacement systems. One hundred twenty patients were randomised to receive either a fixed-bearing or rotating-platform PFC Sigma total knee replacement. Range of movement (ROM), Oxford knee score (OKS) and Knee Society score (KSS) were assessed independently before and one year after surgery. Weight-bearing X-rays were taken immediately and one year post surgery to determine the incidence of osteolysis and loosening. At a mean follow-up of 13.4 months there was no statistically significant difference in mean ROM, OKS and KSS between the two groups. There was no evidence of osteolysis or loosening in either of the groups and no revision for infection or implant failure. This study shows that there is no statistically significant difference in functional outcome between the two types of implants at short-term follow-up.
Similar content being viewed by others
References
Buechel FF Sr, Buechel FF Jr, Pappas MJ, D’Alessio J (2001) Twenty-year evaluation of meniscal bearing and rotating platform knee replacements. Clin Orthop Relat Res 388:41–50
Fisher J, McEwen H, Tipper J, Jennings L, Farrar R, Stone M, Ingham I (2006) Wear-simulation analysis of rotating-platform mobile-bearing knees. Orthopedics 29(9 Suppl):S36–S41
Callaghan JJ, Insall JN, Greenwald AS et al (2000) Mobile-bearing knee replacement: concepts and results. J Bone Joint Surg Am 82(7):1020–1041
Kim YH, Kook HK, Kim JS (2001) Comparison of fixed-bearing and mobile-bearing total knee arthroplasties. Clin Orthop Relat Res 392:101–115
Price AJ, Rees JL, Beard D et al (2003) A mobile-bearing total knee prosthesis compared with a fixed-bearing prosthesis. A multicentre single-blind randomised controlled trial. J Bone Joint Surg Br 85(1):62–67
Woolson ST, Northrop GD (2004) Mobile- vs. fixed-bearing total knee arthroplasty: a clinical and radiologic study. J Arthroplasty 19(2):135–140
Aglietti P, Baldini A, Buzzi R, Lup D, De Luca L (2005) Comparison of mobile-bearing and fixed-bearing total knee arthroplasty: a prospective randomized study. J Arthroplasty 20(2):145–153
Bhan S, Malhotra R, Kiran EK, Shukla S, Bijjawara M (2005) A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years. J Bone Joint Surg Am 87(10):2290–2296
Watanabe T, Tomita T, Fujii M, Hashimoto J, Sugamoto K, Yoshikawa H (2005) Comparison between mobile-bearing and fixed-bearing knees in bilateral total knee replacements. Int Orthop 29(3):179–181
Park KK, Chang CB, Kang YG, Seong SC, Kim TK (2007) Correlation of maximum flexion with clinical outcome after total knee replacement in Asian patients. J Bone Joint Surg Br 89(5):604–608
Jacobs W, Anderson P, Limbeek J, Wymenga A (2004) Mobile bearing vs fixed bearing prostheses for total knee arthroplasty for post-operative functional status in patients with osteoarthritis and rheumatoid arthritis. Cochrane Database Syst Rev (2):CD003130
Ranawat AS, Rossi R, Loreti I, Rasquinha VJ, Rodriguez JA, Ranawat CS (2004) Comparison of the PFC Sigma fixed-bearing and rotating-platform total knee arthroplasty in the same patient: short-term results. J Arthroplasty 19(1):35–39
Evans MC, Parsons EM, Scott RD, Thornhill TS, Zurakowski D (2006) Comparative flexion after rotating-platform vs fixed-bearing total knee arthroplasty. J Arthroplasty 21(7):985–991
Luring C, Bathis H, Oczipka F et al (2006) Two-year follow-up on joint stability and muscular function comparing rotating versus fixed bearing TKR. Knee Surg Sports Traumatol Arthrosc 14(7):605–611
Kim YH, Kim DY, Kim JS (2007) Simultaneous mobile- and fixed-bearing total knee replacement in the same patients. A prospective comparison of mid-term outcomes using a similar design of prosthesis. J Bone Joint Surg Br 89(7):904–910
Ladermann A, Lubbeke A, Stern R, Riand N, Fritschy D (2008) Fixed-bearing versus mobile-bearing total knee arthroplasty: a prospective randomised, clinical and radiological study with mid-term results at 7 years. Knee 15(3):206–210
Higuchi H, Hatayama K, Shimizu M, Kobayashi A, Kobayashi T, Takagishi K (2009) Relationship between joint gap difference and range of motion in total knee arthroplasty: a prospective randomised study between different platforms. Int Orthop 33:997–1000
Dawson J, Fitzpatrick R, Murray D, Carr A (1998) Questionnaire on the perceptions of patients about total knee replacement. J Bone Joint Surg Br 80(1):63–69
Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–14
Health Research Unit (2009) A randomised trial of different knee prosthesis (KAT). http://www.abdn.ac.uk/hsru/research/assessment/interventional/kat/. Accessed 30 Oct 2009
Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12
Oh KJ, Pandher DS, Lee SH, Sung Joon SD,Jr, Lee ST (2008) Meta-analysis comparing outcomes of fixed-bearing and mobile-bearing prostheses in total knee arthroplasty. J Arthroplasty 24(6):873–884
Wylde V, Learmonth I, Potter A, Bettinson K, Lingard E (2008) Patient-reported outcomes after fixed- versus mobile-bearing total knee replacement: a multi-centre randomised controlled trial using the Kinemax total knee replacement. J Bone Joint Surg Br 90(9):1172–1179
Biau D, Mullins MM, Judet T, Piriou P (2006) Mobile versus fixed-bearing total knee arthroplasty: mid-term comparative clinical results of 216 prostheses. Knee Surg Sports Traumatol Arthrosc 14(10):927–933
Cheng K, Ridley D, Bird J, McLeod G (2009) Patients with fixed flexion deformity after total knee arthroplasty do just as well as those without: ten-year prospective data. Int Orthop. doi:10.1007/s00264-009-0801-6
Bert JM (1990) Dislocation/subluxation of meniscal bearing elements after New Jersey low-contact stress total knee arthroplasty. Clin Orthop Relat Res 254:211–215
Weaver JK, Derkash RS, Greenwald AS (1993) Difficulties with bearing dislocation and breakage using a movable bearing total knee replacement system. Clin Orthop Relat Res 290:244–252
Conflict of interest
This study has been sponsored by DePuy International who have provided resources to cover the additional costs of conducting the research over and above standard clinical practice as well as statistical support. None of the authors have received or will receive benefits for personal or professional use from a commercial party related directly or indirectly to the subject of this article.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Hanusch, B., Lou, T.N., Warriner, G. et al. Functional outcome of PFC Sigma fixed and rotating-platform total knee arthroplasty. A prospective randomised controlled trial. International Orthopaedics (SICOT) 34, 349–354 (2010). https://doi.org/10.1007/s00264-009-0901-3
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-009-0901-3