The accuracy of free-hand cup positioning - a CT based measurement of cup placement in 105 total hip arthroplasties

  • Original Paper
  • Published:
International Orthopaedics Aims and scope Submit manuscript

Abstract

We studied 105 patients who received a total hip arthroplasty between June 1985 and August 2001 using freehand positioning of the acetabular cup. Using pelvic CT scan and the hip-plan module of SurgiGATE-System (Medivision, Oberdorf, Switzerland), we measured the angles of inclination and anteversion of the cup. Mean inclination angle was 45.8°±10.1° (range: 23.0–71.5°) and mean anteversion angle was 27.3°±15.0° (range: −23.5° to 59.0°). We compared the results to the “safe” position as defined by Lewinnek et al. and found that only 27/105 cups were implanted within the limits of the safe position. We conclude that a safe position as defined by Lewinnek et al. [13] was only achieved in a minority of the cups that were implanted freehand.

Résumé

Nous avons étudié 105 malades qui ont eu une Arthroplastie Totale de la Hanche entre juin 1985 et août 2001 avec positionnement manuel de la cupule acétabulaire. Utilisant une tomodensitométrie pelvienne et le module de hanche de SurgiGATE© - System (Medivision, Oberdorf, Suisse) nous avons mesuré les angles d’inclination et d’antéversion de la cupule. L’angle moyen d’inclination était 45.8°±10.1° (gamme: 23.0° à 71.5°) et l’angle moyen d’antéversion était 27.3°±15.0° (gamme: -23.5° à 59.0°). Nous avons comparé les résultats à l’orientation de sécurité définie par Lewinnek et al. et nous avons trouvé que seulement 27/105 cupules ont été implantées dans les limites de l’orientation correctes. Nous concluons qu’une orientation de sécurité, comme défini par Lewinnek et al. [13] n’a été obtenue que dans une minorité des cupules implantées manuellement.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

Explore related subjects

Discover the latest articles, news and stories from top researchers in related subjects.

References

  1. Bernsmann K, Langlotz U, Ansari B, Wiese M (2001) Computer-assisted navigated cup placement of different cup types in hip arthroplasty-a randomised controlled trial. Z Orthop Ihre Grenzgeb 139:512–517

    Article  CAS  PubMed  Google Scholar 

  2. Coventry MB, Beckenbaugh RD, Nolan DR, Ilstrup DM (1974) 2,012 total hip arthroplasties. A study of postoperative course and early complications. J Bone Joint Surg [Am] 56:273–284

    Google Scholar 

  3. DiGioia AM, Jaramaz B, Blackwell M, Simon DA, Morgan F, Moody JE, Nikou C, Colgan BD, Aston CA, Labarca RS, Kischell E, Kanade T (1998) The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop 355:8-22

    PubMed  Google Scholar 

  4. Harris WH (1980) Advances in surgical technique for total hip replacement: without and with osteotomy of the greater trochanter. Clin Orthop 146:188–204

    PubMed  Google Scholar 

  5. Herrlin K, Pettersson H, Selvik G (1988) Comparison of two- and three-dimensional methods for assessment of orientation of the total hip prosthesis. Acta Radiol 29:357–361

    CAS  PubMed  Google Scholar 

  6. Hirakawa K, Mitsugi N, Koshino T, Saito T, Hirasawa Y, Kubo T (2001) Effect of acetabular cup position and orientation in cemented total hip arthroplasty. Clin Orthop 388:135–142

    PubMed  Google Scholar 

  7. Jaramaz B, DiGioia AM 3rd, Blackwell M, Nikou C (1998) Computer assisted measurement of cup placement in total hip replacement. Clin Orthop 354:70–81

    PubMed  Google Scholar 

  8. Jolles BM, Genoud P, Hoffmeyer P (2001) Accuracy of computer – assisted cup placement in total hip arthroplasty. International Congress Series 1230:314–318

    Article  Google Scholar 

  9. Joshi A, Lee CM, Markovic L, Vlatis G, Murphy JC (1998) Prognosis of dislocation after total hip arthroplasty. J Arthroplasty 13:17–21

    Google Scholar 

  10. Kohn D, Ruhmann O, Wirth CJ (1997) Dislocation of total hip endoprosthesis with special reference to various techniques. Z Orthop Ihre Grenzgeb 135:40–44

    CAS  PubMed  Google Scholar 

  11. Langlotz U, Lawrence J, Hu Q, Langlotz F, Nolte LP (1999) Image guided cup placement. Amsterdam, Elsevier

  12. Leenders T, Vandevelde D, Mahieu G, Nuyts R (2002) Reduction in variability of acetabular cup abduction using computer assisted surgery: A prospective and randomized study. Comput Aided Surg 7:99–106

    Google Scholar 

  13. Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmermann JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg [Am] 60:217–220

    Google Scholar 

  14. McCollum DE, Gray WJ (1990) Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop 261:159–170

    PubMed  Google Scholar 

  15. Mian SW, Truchly G, Pflum FA (1992) Computed tomography measurement of acetabular cup anteversion and retroversion in total hip arthroplasty. Clin Orthop 276:206–209

    PubMed  Google Scholar 

  16. Morrey BF(1992) Instability after total hip arthroplasty. Orthop Clin North Am. 23:237–248

  17. Müller ME (1974)Total Hip Prosthesis. Clin Orthop 72:46–68

    Google Scholar 

  18. Murray DW (1993) The definition and measurement of acetabular orientation. J Bone Joint Surg [Br] 75:228–232

    Google Scholar 

  19. Pierchon F, Pasquier G, Cotten A, Fontaine C, Clarisse J, and Duquennoy A (1994) Causes of dislocation of total hip arthroplasty. CT study of component alignment. J Bone Joint Surg [Br] 76:45–48

    Google Scholar 

  20. Tannast M (2000) The measurement of anteversion and inclination with respect to the pelvic frontal plane. M.D.Thesis, University of Bern

  21. Yuan L, Shih C (1999) Dislocation after total hip arthroplasty. Arch Orthop Trauma Surg. 119:263–266

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to G. Saxler.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Saxler, G., Marx, A., Vandevelde, D. et al. The accuracy of free-hand cup positioning - a CT based measurement of cup placement in 105 total hip arthroplasties. International Orthopaedics (SICOT) 28, 198–201 (2004). https://doi.org/10.1007/s00264-004-0542-5

Download citation

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00264-004-0542-5

Keywords

Navigation