T2-weighted MR imaging for hepatic hemangiomas: comparison of breath-hold and non-breath-hold turbo spin-echo pulse sequences with phased-array multicoil

  • Published:
Abdominal Imaging Aims and scope Submit manuscript

Abstract

Background: We compared T2-weighted and heavily T2-weighted breath-hold turbo spin-echo (TSE) sequences with T2-weighted non-breath-hold TSE sequence to evaluate hepatic hemangiomas on magnetic resonance (MR) with a phased-array multicoil.

Methods: Twenty-two patients with 27 hemangiomas were studied at 1.0-T scanner by using T2-weighted and heavily T2-weighted breath-hold TSE sequences (18 s each) and non-breath-hold T2-weighted TSE sequences with use of a phased-array multicoil. Images were quantitatively analyzed for tumor-to-liver signal-difference-to-noise ratios (SD/Ns) and tumor-to-liver signal intensity ratios (T/Ls) and qualitatively analyzed for tumor conspicuity and motion-induced image artifacts.

Results: Quantitatively, T2-weighted breath-hold TSE images showed the highest SD/Ns among the three sequences, although the differences from the heavily T2-weighted breath-hold TSE sequence and the T2-weighted non-breath-hold TSE sequence were not statistically significant (p= 0.61 and 0.06, respectively). Heavily T2-weighted breath-hold TSE images showed the highest T/Ls among the three sequences. The differences from the T2-weighted breath-hold TSE sequence and the T2-weighted non-breath-hold TSE sequence were statistically significant (p < 0.001). Qualitatively, breath-hold TSE images were superior to non-breath-hold TSE images in terms of tumor conspicuity (p < 0.01) and motion artifacts (p < 0.01).

Conclusion: T2-weighted breath-hold TSE sequence is superior to T2-weighted non-breath-hold TSE sequence in the evaluation of hepatic hemangiomas on MR with a phased-array multicoil.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kim, T., Wang, W., Han, J. et al. T2-weighted MR imaging for hepatic hemangiomas: comparison of breath-hold and non-breath-hold turbo spin-echo pulse sequences with phased-array multicoil. Abdom Imaging 23, 422–426 (1998). https://doi.org/10.1007/s002619900372

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002619900372

Key words

Navigation