Comparison of low kVp CT and dual-energy CT for the evaluation of hypervascular hepatocellular carcinoma

  • Hepatobiliary
  • Published:
Abdominal Radiology Aims and scope Submit manuscript

Abstract

Purpose

To compare lesion conspicuity and image quality of arterial phase images obtained from low kVp (90-kVp) and dual-energy (DE) scans for the evaluation of hypervascular hepatocellular carcinoma (HCC).

Methods

This retrospective study included 229 patients with HCC who underwent either 90 kVp (n = 106) or DE scan (80- and 150-kVp with a tin filter) (n = 123) during the arterial phase. DE scans were reconstructed into a linearly blended image with a mixed ratio of 0.6 (60% 80kVp and 40% 150 kVp) and post-processed for 40 keV and 50 keV images. The contrast-to-noise ratio (CNR) of HCC to the liver and image noise was measured. Lesion conspicuity, liver parenchymal image quality, and overall image preference were assessed qualitatively by three independent radiologists.

Results

DE 40 keV images had the highest CNR of HCC, and DE blended images had the lowest image noise among four image sets (p = 0.01 and p < 0.001, respectively). There was no significant difference in mean volume CT dose index and dose-length product between DE and low kVp scan (ps > 0.05). For qualitative analyses, DE blended images had the highest scores for image quality and overall image preference (ps < 0.001).

Conclusion

At an equal radiation dose, DE 40 keV showed higher CNR of HCC and DE blended image showed higher image quality and image preference compared with low kVp CT.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

Data availability

We declared that materials described in the manuscript, including all relevant raw data, will be freely available to any scientist wishing to use them for non-commercial purposes, without breaching participant confidentiality.

Code availability

All softwares used during the study appear in the submitted article; No code was generated or used during the study.

References

  1. Mittal S, El-Serag HB (2013) Epidemiology of HCC: consider the population. J Clin Gastroenterol 47:S2

  2. Bray F, Ferlay J, Soerjomataram I, Siegel RL, Torre LA, Jemal A (2018) Global cancer statistics 2018: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin 68 (6):394-424

  3. Ghouri YA, Mian I, Rowe JH (2017) Review of hepatocellular carcinoma: Epidemiology, etiology, and carcinogenesis. J Carcinog 16:1. https://doi.org/10.4103/jcar.JCar_9_16

  4. Bertuccio P, Turati F, Carioli G, Rodriguez T, La Vecchia C, Malvezzi M, Negri E (2017) Global trends and predictions in hepatocellular carcinoma mortality. J Hepatol 67 (2):302-309. https://doi.org/10.1016/j.jhep.2017.03.011

  5. Elsayes KM, Hooker JC, Agrons MM, Kielar AZ, Tang A, Fowler KJ, Chernyak V, Bashir MR, Kono Y, Do RK (2017) 2017 version of LI-RADS for CT and MR imaging: An update. Radiographics 37 (7):1994-2017

  6. Bruix J, Llovet JM (2009) Major achievements in hepatocellular carcinoma. The Lancet 373 (9664):614-616. https://doi.org/10.1016/S0140-6736(09)60381-0

  7. Awai K, Takada K, Onishi H, Hori S (2002) Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effect of different concentrations of contrast material at multi–detector row helical CT. Radiology 224 (3):757-763

  8. Funama Y, Awai K, Nakayama Y, Kakei K, Nagasue N, Shimamura M, Sato N, Sultana S, Morishita S, Yamashita Y (2005) Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low–tube voltage technique: phantom study. Radiology 237 (3):905-910

  9. Foley WD, Mallisee TA, Hohenwalter MD, Wilson CR, Quiroz FA, Taylor AJ (2000) Multiphase hepatic CT with a multirow detector CT scanner. American Journal of Roentgenology 175 (3):679-685

  10. Bushberg JT, Seibert JA, Leidholdt E, Boone JM (2012) The essential physics of medical imaging. Philadelphia, PA: Lippicont Williams & Wilkins

  11. Nakayama Y, Awai K, Funama Y, Hatemura M, Imuta M, Nakaura T, Ryu D, Morishita S, Sultana S, Sato N (2005) Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise. Radiology 237 (3):945-951

  12. Marin D, Nelson RC, Samei E, Paulson EK, Ho LM, Boll DT, DeLong DM, Yoshizumi TT, Schindera ST (2009) Hypervascular liver tumors: low tube voltage, high tube current multidetector CT during late hepatic arterial phase for detection—initial clinical experience. Radiology 251 (3):771-779

  13. Kalra MK, Maher MM, Blake MA, Lucey BC, Karau K, Toth TL, Avinash G, Halpern EF, Saini S (2004) Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters. Radiology 232 (3):791-797

  14. Shuman WP, Green DE, Busey JM, Mitsumori LM, Choi E, Koprowicz KM, Kanal KM (2014) Dual-energy liver CT: effect of monochromatic imaging on lesion detection, conspicuity, and contrast-to-noise ratio of hypervascular lesions on late arterial phase. American Journal of Roentgenology 203 (3):601-606

  15. McCollough CH, Primak AN, Braun N, Kofler J, Yu L, Christner J (2009) Strategies for reducing radiation dose in CT. Radiologic Clinics 47 (1):27-40

  16. Wichmann J, Kraft J, Nöske E-M, Bodelle B, Burck I, Scholtz J-E, Frellesen C, Wagenblast J, Kerl J, Bauer R (2014) Low-tube-voltage 80-kVp neck CT: evaluation of diagnostic accuracy and interobserver agreement. American Journal of Neuroradiology 35 (12):2376-2381

  17. Foley WD, Shuman WP, Siegel MJ, et al. (2016) White Paper of the Society of Computed Body Tomography and Magnetic Resonance on Dual-Energy CT, Part 2: Radiation Dose and Iodine Sensitivity. J Comput Assist Tomogr 40(6):846–850. https://doi.org/10.1097/rct.0000000000000539

    Article  PubMed  Google Scholar 

  18. Mazzei MA, Gentili F, Volterrani L (2019) Dual-Energy CT Iodine Mapping and 40-keV Monoenergetic Applications in the Diagnosis of Acute Bowel Ischemia: A Necessary Clarification. AJR Am J Roentgenol 212(3):W93–w94. https://doi.org/10.2214/ajr.18.20501

    Article  PubMed  Google Scholar 

  19. Volterrani L, Gentili F, Fausto A, Pelini V, Megha T, Sardanelli F, Mazzei MA (2020) Dual-Energy CT for Locoregional Staging of Breast Cancer: Preliminary Results. AJR Am J Roentgenol 214 (3):707-714. https://doi.org/10.2214/ajr.18.20953

  20. Alshipli M, Kabir NA Effect of slice thickness on image noise and diagnostic content of single-source-dual energy computed tomography. In: J Physics: Conf Series, 2017. pp 1-6

  21. Grajo JR, Sahani DV (2018) Dual-energy CT of the abdomen and pelvis: radiation dose considerations. Journal of the American College of Radiology 15 (8):1128-1132

  22. Simons D, Kachelrieß M, Schlemmer H-P (2014) Recent developments of dual-energy CT in oncology. Eur Radiol 24 (4):930-939

  23. Patel BN, Alexander L, Allen B, Berland L, Borhani A, Mileto A, Moreno C, Morgan D, Sahani D, Shuman W (2017) Dual-energy CT workflow: multi-institutional consensus on standardization of abdominopelvic MDCT protocols. Abdominal Radiology 42 (3):676-687

  24. Lv P, Zhou Z, Liu J, Chai Y, Zhao H, Guo H, Marin D, Gao J (2019) Can virtual monochromatic images from dual-energy CT replace low-kVp images for abdominal contrast-enhanced CT in small-and medium-sized patients? Eur Radiol 29 (6):2878-2889

  25. Galle PR, Forner A, Llovet JM, Mazzaferro V, Piscaglia F, Raoul J-L, Schirmacher P, Vilgrain V (2018) EASL clinical practice guidelines: management of hepatocellular carcinoma. J Hepatol

  26. Ellmann S, Kammerer F, Allmendinger T, Hammon M, Janka R, Lell M, Uder M, Kramer M (2018) Advanced modeled iterative reconstruction (ADMIRE) facilitates radiation dose reduction in abdominal CT. Acad Radiol 25 (10):1277-1284

  27. Kim KS, Lee JM, Kim SH, Kim KW, Kim SJ, Cho SH, Han JK, Choi BI (2010) Image fusion in dual energy computed tomography for detection of hypervascular liver hepatocellular carcinoma: phantom and preliminary studies. Invest Radiol 45 (3):149-157. https://doi.org/10.1097/RLI.0b013e3181d32119

  28. Schindera ST, Nelson RC, Mukundan Jr S, Paulson EK, Jaffe TA, Miller CM, DeLong DM, Kawaji K, Yoshizumi TT, Samei E (2008) Hypervascular liver tumors: low tube voltage, high tube current multi–detector row CT for enhanced detection—phantom study. Radiology 246 (1):125-132

  29. Hur S, Lee JM, Kim SJ, Park JH, Han JK, Choi BI (2012) 80-kVp CT using Iterative Reconstruction in Image Space algorithm for the detection of hypervascular hepatocellular carcinoma: phantom and initial clinical experience. Korean journal of radiology 13 (2):152-164

  30. Gao S-Y, Zhang X-P, Cui Y, Sun Y-S, Tang L, Li X-T, Zhang X-Y, Shan J (2014) Fused monochromatic imaging acquired by single source dual energy CT in hepatocellular carcinoma during arterial phase: an initial experience. Chinese Journal of Cancer Research 26 (4):437

  31. Lg P, Watkins M (2000) Foundations of clinical research: applications to practice. Upper Saddle River, NJ: Prentice Hall Health

  32. Cruite I, Tang A, Sirlin CB (2013) Imaging-based diagnostic systems for hepatocellular carcinoma. American Journal of Roentgenology 201 (1):41-55

  33. Bruix J, Sherman M (2011) Management of hepatocellular carcinoma: an update. Hepatology 53 (3):1020-1022

  34. Heimbach JK, Kulik LM, Finn RS, Sirlin CB, Abecassis MM, Roberts LR, Zhu AX, Murad MH, Marrero JA (2018) AASLD guidelines for the treatment of hepatocellular carcinoma. Hepatology 67 (1):358-380

  35. Kim M, Kang TW, Cha DI, Jang KM, Kim YK, Kim SH, Sinn DH, Kim K (2019) Identification of Arterial Hyperenhancement in CT and MRI in Patients with Hepatocellular Carcinoma: Value of Unenhanced Images. Korean J Radiol 20 (2):236-245. https://doi.org/10.3348/kjr.2018.0339

  36. Cui Y, Gao S, Wang Z, Li X, Sun Y, Tang L, Zhang X (2012) Which should be the routine cross-sectional reconstruction mode in spectral CT imaging: monochromatic or polychromatic? The British journal of radiology 85 (1018):e887-e890

  37. Yu L, Christner JA, Leng S, Wang J, Fletcher JG, McCollough CH (2011) Virtual monochromatic imaging in dual‐source dual‐energy CT: Radiation dose and image quality. Med Phys 38 (12):6371-6379

  38. Grant KL, Flohr TG, Krauss B, Sedlmair M, Thomas C, Schmidt B (2014) Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media. Invest Radiol 49 (9):586-592

  39. Goenka AH, Herts BR, Dong F, Obuchowski NA, Primak AN, Karim W, Baker ME (2016) Image noise, CNR, and detectability of low-contrast, low-attenuation liver lesions in a phantom: effects of radiation exposure, phantom size, integrated circuit detector, and iterative reconstruction. Radiology 280 (2):475-482

  40. Schindera ST, Odedra D, Raza SA, Kim TK, Jang H-J, Szucs-Farkas Z, Rogalla P (2013) Iterative reconstruction algorithm for CT: can radiation dose be decreased while low-contrast detectability is preserved? Radiology 269 (2):511-518

  41. Hanson GJ, Michalak GJ, Childs R, McCollough B, Kurup AN, Hough DM, Frye JM, Fidler JL, Venkatesh SK, Leng S (2018) Low kV versus dual-energy virtual monoenergetic CT imaging for proven liver lesions: what are the advantages and trade-offs in conspicuity and image quality? A pilot study. Abdominal Radiology 43 (6):1404-1412

  42. Yao Y, Ng JM, Megibow AJ, Pelc NJ (2016) Image quality comparison between single energy and dual energy CT protocols for hepatic imaging. Med Phys 43 (8Part1):4877-4890

  43. Rizzo S, Kalra M, Schmidt B, Dalal T, Suess C, Flohr T, Blake M, Saini S (2006) Comparison of Angular and Combined Automatic Tube Current Modulation Techniques with Constant Tube Current CT of the Abdomen and Pelvis. American Journal of Roentgenology 186 (3):673-679. https://doi.org/10.2214/AJR.04.1513

  44. Mulkens TH, Bellinck P, Baeyaert M, Ghysen D, Van Dijck X, Mussen E, Venstermans C, Termote JL (2005) Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation. Radiology 237 (1):213-223. https://doi.org/10.1148/radiol.2363041220

  45. McCollough CH, Bruesewitz MR, Kofler JM, Jr. (2006) CT dose reduction and dose management tools: overview of available options. Radiographics 26 (2):503-512. https://doi.org/10.1148/rg.262055138

  46. Lee KH, Lee JM, Moon SK, Baek JH, Park JH, Flohr TG, Kim KW, Kim SJ, Han JK, Choi BI (2012) Attenuation-based automatic tube voltage selection and tube current modulation for dose reduction at contrast-enhanced liver CT. Radiology 265 (2):437-447. https://doi.org/10.1148/radiol.12112434

  47. Lv P, Liu J, Zhang R, Jia Y, Gao J (2015) Combined use of automatic tube voltage selection and current modulation with iterative reconstruction for CT evaluation of small hypervascular hepatocellular carcinomas: effect on lesion conspicuity and image quality. Korean journal of radiology 16 (3):531-540

Download references

Funding

The authors did not receive support from any organization for the submitted work.

Author information

Authors and Affiliations

Authors

Contributions

Study conception and design: JML; Acquisition of data: JY; Data Analysis: ESL, SKJ, SJ; Data interpretation: JY; Drafting of manuscript: JY; Critical revision of manuscript: JHY, IJ, JML.

Corresponding author

Correspondence to Jeong Min Lee.

Ethics declarations

Conflict of interest

The authors have no relevant financial or non-financial interests to disclose.

Ethical approval

This study was approved by Institutional Review Board of Seoul National University Hospital and in accordance with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.

Informed consent

Written informed consent was waived by Institutional Review Board of Seoul National University Hospital due to retrospective design of the study.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yoo, J., Lee, J.M., Yoon, J.H. et al. Comparison of low kVp CT and dual-energy CT for the evaluation of hypervascular hepatocellular carcinoma. Abdom Radiol 46, 3217–3226 (2021). https://doi.org/10.1007/s00261-020-02888-7

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00261-020-02888-7

Keywords

Navigation