Abstract
Purpose
The purpose of this study was to evaluate the efficacy of CT-guided percutaneous biopsy of isoattenuating liver lesions using anatomic landmarks (ALs) to guide needle placement and added value of intravenous (IV) contrast.
Methods
An interventional radiology database was reviewed to identify patients with CT-guided percutaneous biopsy of isoattenuating focal liver lesions using ALs to guide needle placement. The cohort was further divided into two groups: lesions biopsied using ALs only and lesions biopsied using ALs and intravenous contrast (AL+IV). Pathology results or follow-up imaging served as reference standard. Sensitivity and accuracy were calculated, Student’s t test and Fisher’s exact test were used for statistical comparison between the two groups.
Results
Between January 2000 and December 2011, CT-guided percutaneous biopsy of 133 isoattenuating focal liver lesions was performed in 133 patients. The AL group included 54 patients (M:F = 29:25) with 54 lesions (size range 7–90 mm, mean 32.1 ± 18.1) and AL+IV group included 79 patients (M:F = 44:35) with 79 lesions (size range 7–100 mm, mean 25.6 ± 15.0). AL group included 23 (43%) benign and 31 (57%) malignant lesions; AL+IV group included 31 (39%) benign and 48 (61%) malignant lesions. Sensitivity and accuracy for CT-guided biopsy of focal isoattenuating liver lesions were, overall 94% and 96%, AL group 97% and 98% and AL+IV group 92% and 94%, with no statistical significant difference between the AL and AL+IV groups (P = 0.88–1.00).
Conclusion
Accurate planning and utilizing of internal reference ALs is successful in yielding a diagnostic sample for CT-guided percutaneous biopsy of isoattenuating focal liver lesion. The confidence of accurate targeting can be enhanced by administering IV contrast, however, since the visualization provided by IV contrast can be short-lived; use of IV contrast does not obviate the need for precise planning based on ALs.
Similar content being viewed by others
References
Martino CR, Haaga JR, Bryan PJ, et al. (1984) CT-guided liver biopsies: eight years’ experience. Work in progress. Radiology 152:755–757
Yu SC, Lau WY, Leung WT, et al. (1998) Percutaneous biopsy of small hepatic lesions using an 18 gauge automated needle. Br J Radiol 71:621–624
Stattaus J, Kuehl H, Ladd S, et al. (2007) CT-guided biopsy of small liver lesions: visibility, artifacts, and corresponding diagnostic accuracy. Cardiovasc Intervent Radiol 30:928–935
Harbin WP, Robert NJ, Ferrucci JT Jr (1980) Diagnosis of cirrhosis based on regional changes in hepatic morphology: a radiological and pathological analysis. Radiology 135:273–283
Ohtomo K, Baron RL, Dodd GD 3rd, et al. (1993) Confluent hepatic fibrosis in advanced cirrhosis: appearance at CT. Radiology 188:31–35
Torres WE, Whitmire LF, Gedgaudas-McClees K, Bernardino ME (1986) Computed tomography of hepatic morphologic changes in cirrhosis of the liver. J Comput Assist Tomogr 10:47–50
Marti-Bonmati L, Talens A, del Olmo J, et al. (1993) Chronic hepatitis and cirrhosis: evaluation by means of MR imaging with histologic correlation. Radiology 188:37–43
Bahl M, Qayyum A, Westphalen AC, et al. (2008) Liver steatosis: investigation of opposed-phase T1-weighted liver MR signal intensity loss and visceral fat measurement as biomarkers. Radiology 249:160–166
Charboneau JW, Reading CC, Welch TJ (1990) CT and sonographically guided needle biopsy: current techniques and new innovations. AJR Am J Roentgenol 154:1–10
Kettenbach J, Blum M, El-RaBadi K, et al. (2005) Percutaneous liver biopsy. Overview of different techniques. Der Radiologe 45:44–54
Willatt JM, Hussain HK, Adusumilli S, Marrero JA (2008) MR imaging of hepatocellular carcinoma in the cirrhotic liver: challenges and controversies. Radiology 247:311–330
Copel L, Sosna J, Kruskal JB, Kane RA (2003) Ultrasound-guided percutaneous liver biopsy: indications, risks, and technique. Surg Technol Int 11:154–160
Ha HK, Sachs PB, Haaga JR, Abdul-Karim F (1991) CT-guided liver biopsy: an update. Clin Imaging 15:99–104
Albrecht T, Hohmann J, Oldenburg A, Skrok J, Wolf KJ (2004) Detection and characterisation of liver metastases. Eur Radiol 14(Suppl 8):P25–P33
Hohmann J, Skrok J, Puls R, Albrecht T (2003) Characterization of focal liver lesions with contrast-enhanced low MI real time ultrasound and SonoVue. RoFo Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin 175:835–843
Lencioni R, Della Pina C, Crocetti L, Bozzi E, Cioni D (2007) Clinical management of focal liver lesions: the key role of real-time contrast-enhanced US. Eur Radiol 17(Suppl 6):F73–F79
Mok TS, Yu SC, Lee C, et al. (2004) False-negative rate of abdominal sonography for detecting hepatocellular carcinoma in patients with hepatitis B and elevated serum alpha-fetoprotein levels. AJR Am J Roentgenol 183:453–458
Saar B, Kellner-Weldon F (2008) Radiological diagnosis of hepatocellular carcinoma. Liver Int 28:189–199
Appelbaum L, Kane RA, Kruskal JB, Romero J, Sosna J (2009) Focal hepatic lesions: US-guided biopsy lessons from review of cytologic and pathologic examination results. Radiology 250:453–458
Pagani JJ (1983) Biopsy of focal hepatic lesions. Comparison of 18 and 22 gauge needles. Radiology 147:673–675
Cardella JF, Bakal CW, Bertino RE, et al. (2003) Society of Interventional Radiology Standards of Practice Committee. Quality improvement guidelines for image-guided percutaneous biopsy in adults. J Vasc Interv Radiol 14:S227–S230
Shimizu A, Ito K, Koike S, et al. (2003) Cirrhosis or chronic hepatitis: evaluation of small (≤2-cm) early-enhancing hepatic lesions with serial contrast-enhanced dynamic MR imaging. Radiology 226:550–555
Caturelli E, Solmi L, Anti M, et al. (2004) Ultrasound guided fine needle biopsy of early hepatocellular carcinoma complicating liver cirrhosis: a multicentre study. Gut 53:1356–1362
Yoshimitsu K, Irie H, Aibe H, et al. (2004) Pitfalls in the imaging diagnosis of hepatocellular nodules in the cirrhotic and noncirrhotic liver. Intervirology 47:238–251
Fornari F, Filice C, Rapaccini GL, et al. (1994) Small (≤3 cm) hepatic lesions. Results of sonographically guided fine-needle biopsy in 385 patients. Dig Dis Sci 39:2267–2275
Choi BI, Han JK, Cho JM, et al. (1995) Characterization of focal hepatic tumors. Value of two-phase scanning with spiral computed tomography. Cancer 76:2434–2442
Kirchner J, Kickuth R, Walz MV, et al. (1999) CTF-guided puncture of an unenhanced isodense liver lesion during continuous intravenous injection of contrast medium. Cardiovasc Intervent Radiol 22:528–530
Lucidarme O, Howarth N, Finet JF, Grenier PA (1998) Intrapulmonary lesions: percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle. Radiology 207:759–765
Silverman SG, Tuncali K, Adams DF, et al. (1999) CT fluoroscopy-guided abdominal interventions: techniques, results, and radiation exposure. Radiology 212:673–681
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Sainani, N.I., Schlett, C.L., Hahn, P.F. et al. Computed tomography-guided percutaneous biopsy of isoattenuating focal liver lesions. Abdom Imaging 39, 633–644 (2014). https://doi.org/10.1007/s00261-014-0089-x
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00261-014-0089-x