Abstract
Endovascular aortic aneurysm repair (EVAR) is considered an acceptable alternative to open surgery in selected patients. Its feasibility depends mainly on anatomic factors that represent the important predictors of success and the most important exclusion criteria. Poor anatomic patient selection is generally associated with a higher risk for procedural complications and compromised long-term outcomes. Therefore pretreatment imaging is crucial for evaluating patient suitability for EVAR. Multidetector computed tomographic angiography represents the current standard of reference in the evaluation of the abdominal aorta and iliac axis anatomy because it provides all the details needed for selection of patients who are suitable for endograft and the choice of the appropriate device. This report identifies and reviews computed tomographic angiographic anatomic contraindications for EVAR.
Similar content being viewed by others
References
Makaroun MS, Chaikof E, Naslund T, Matsumara JS (2002) Efficacy of a bifurcated endograft versus open repair of abdominal aortic aneurysms: a reappraisal. J Vasc Surg 35:203–210
Elkouri S, Gloviczki P, Panneton JM, et al. (2004) Perioperative complications and early outcome after endovascular and open surgical repair of abdominal aortic aneurysms. J Vasc Surg 39:497–505
Cao P, Parlani G, Romano L, et al. (2004) Clinical effect of abdominal aortic aneurysm endografting: 7-year concurrent comparison with open repair. J Vasc Surg 40:841–848
Greenhalgh RM, Brown LC, Kwong GP, et al. (2004) Comparison of endovascular aneurysm repair with open repair in patients with abdominal aortic aneurysm (EVAR trial 1), 30-day operative mortality results: randomised controlled trial. Lancet 364:843–848
Rockman C (2004) Reducing complications by better case selection: anatomic considerations. Semin Vasc Surg 17:298–306
Tefera G, Carr SC, Turnipseed WD (2004) Endovascular aortic repair or minimal incision aortic surgery: which procedure to choose for treatment of high risk aneurysms? Surgery 136:748–753
Biebl M, Lau LL, Hakaim AG, et al. (2004) Midterm outcome of endovascular abdominal aortic aneurysm repair in octogenarians: a single institution’s experience. J Vasc Surg 40:435–442
Prinssen M, Buskens E, Blankensteijn JD, DREAM Trial Participants. (2004) Quality of life after endovascular and open AAA repair. Results of a randomized trial. Eur J Vasc Endovasc Surg 27:121–127
Garcia-Madrid C, Josa M, Riambau V, et al. (2004) Endovascular versus open surgical repair of abdominal aortic aneurysm: a comparison for early and intermediate results in patients suitable for both techniques. Eur J Vasc Endovasc Surg 28:365–372
Treiman GS, Lawrence PF, Edwards WH, et al. (1999) An assessment of the current applicability of the EVT endovascular graft for treatment of patients with an infrarenal abdominal aortic aneurysm. J Vasc Surg 30:68–75
Matsumura JS, Pearce WH (1999) Early clinical results and studies of aortic aneurysm morphology after endovascular repair. Surg Clin North Am 79:529–540
Fishman EK (2001) CT angiography: clinical applications in the abdomen. Radiographics 21:3–16
Prokop M (2000) Multislice CT angiography. Eur Radiol 36:86–96
Prokop M, Schaefer-Prokop C, Galanski M (1997) Spiral CT angiography of the abdomen. Abdom Imaging 22:143–153
Fleischmann D, Hittmair K (2000) Mathematical analysis of arterial enhancement and optimization of bolus geometry for CT angiography using the discrete Fourier transform. J Comput Assist Tomogr 23:474–484
Rubin GD, Shiau MC, Leung AN, et al. (2000) Aorta and iliac arteries: single versus multiple detector-row helical CT angiography. Radiology 215:670–676
Silverman PM, Roberts S, Tefft MC, et al. (1995) Helical CT of the liver: clinical application of an automated computer technique, SmartPrep, for obtained images with optimal contrast enhancement. AJR 165:73–78
Rubin GD (2000) Data explosion: the challenge of multidetector row CT. Eur Radiol 36:74–80
Arko FR, Kostantinos AF, Seidel SA, et al. (2004) How many patients with infrarenal aneurysms are candidates for endovascular repair? The Northern California Experience. J Endovasc Ther 11:33–40
Armerding MA, Rubin GD, Beaulieu CF, et al. (2000) Aortic aneurysmal disease: assessment of stent-graft treatment—CT versus conventional angiography. Radiology 215:138–146
Sternbergh WC, Money SR, Greenberg RK, et al. (2004) Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilatation: results from the Zenith multicenter trial. J Vasc Surg 39:20–26
Greenberg RK, Haulon S, O’Neill S, et al. (2004) Primary endovascular repair of juxtarenal aneurysms with fenestrated endovascular grafting. Eur J Vasc Endovasc Surg 27:484–491
Verhoeven EL, Prins TR, Tielliu IF, et al. (2004) Treatment of short-necked infrarenal aortic aneurysms with fenestrated stent-grafts: short-term results. Eur J Vasc Endovasc Surg 27:453–455
Balm R, Stokking R, Kaatee R, et al. (1997) Computed tomographic angiographic imaging of abdominal aortic aneurysms: implications for transfemoral endovascular aneurysm management. J Vasc Surg 26:231–237
Sternbergh WC, Carter G, York JW, et al. (2002) Aortic neck angulation predicts adverse outcome with endovascular abdominal aortic aneurysm repair. J Vasc Surg 35:482–486
Robbins M, Kritpracha B, Beebe HG, et al. (2005) Suprarenal endograft fixation avoids adverse outcomes associated with aortic neck angulation. Ann Vasc Surg 19:172–177
Stanley BM, Semmens JB, Mai Q, et al. (2001) Evaluation of patient selection guidelines for endoluminal AAA repair with the Zenith stent-graft: the Australasian experience. J Endovasc Ther 8:457–464
Armon MP, Yusuf SW, Whitaker SC, et al. (1997) Influence of abdominal aortic aneurysm size on the feasibility of endovascular repair. Endovasc Surg 4:279–283
Peppelenbosch N, Buth J, Harris PL, et al. (2004) Diameter of abdominal aortic aneurysm and outcome of endovascular aneurysm repair: does size matter? A report from EUROSTAR. J Vasc Surg 39:288–297
Lange C, Hobo R, Leurs LJ, et al. (2005) Results of endovascular repair of inflammatory abdominal aortic aneurysms. A report from the EUROSTAR database. J Vasc Endovasc Surg 29:363–370
Ahn SS, Ro KM (2001) Design of endovascular grafts for abdominal aortic aneurysm repair. Ann Vasc Surg 15:123–127
Schumacher H, Eckstein HH, Kallinowski F, Allenberg JR (1997) Morphometry and classification in abdominal aortic aneurysms: patient selection for endovascular and open surgery. J Endovasc Surg 4:39–44
Carpenter JP, Baum RA, Barker CF, et al. (2001) Impact of exclusion criteria on patient selection for endovascular abdominal aortic aneurysm repair. J Vasc Surg 34:1050–1054
Timaran CH, Lipsitz EC, Veith FJ, et al. (2005) Endovascular Aortic aneurysm repair with the Zenith endograft in patients with ecstatic iliac arteries. Ann Vasc Surg 19:161–166
Armon MP, Yusuf SW, Whitaker SC, et al. (1998) Thrombus distribution and changes in aneurysm size following endovascular aortic aneurysm repair. Eur J Vasc Endovasc Surg 16:472–476
Karch LA, Hodgson KJ, Mattos MA, et al. (2001) Management of ectatic, nonaneurysmal iliac arteries during endoluminal aortic aneurysm repair. J Vasc Surg 33:33–38
Kritpracha B, Pigott JP, Russell TE, et al. (2002) Bell-bottom aortoiliac endografts: an alternative that preserves pelvic blood flow. J Vasc Surg 35:874–881
Yano OJ, Morrissey N, Eisen L, et al. (2001) Intentional internal iliac artery occlusion to facilitate endovascular repair of aortoiliac aneurysms. J Vasc Surg 34:204–211
Schoder M, Zaunbauer L, Holzenbein T, et al. (2001) Internal iliac artery embolization before endovascular repair of abdominal aortic aneurysms: frequency, efficacy, and clinical results. AJR 177:599–605
Marin ML, Veith FJ, Cynamon J, et al. (1995) Initial experience with transluminally placed endovascular grafts for the treatment of complex vascular lesions. Ann Surg 222:449–465
Engelke C, Elford J, Morgan RA, Belli AM (2002) Internal iliac artery embolization with bilateral occlusion before endovascular aortoiliac aneurysm repair-clinical outcome of simultaneous and sequential intervention. J Vasc Interv Radiol 13:667–676
Dadian N, Ohki T, Veith FJ, et al. (2001) Overt colon ischemia after endovascular aneurysm repair: the importance of microembolization as an etiology. J Vasc Surg 34:986–996
Dawson DL, Hellinger JC, Terramani TT, et al. (2002) Iliac artery kinking with endovascular therapies: technical considerations. J Vasc Interv Radiol 13:729–733
Criado FJ, Wilson EP, Velazquez OC, et al. (2000) Safety of coil embolization of the internal iliac artery in endovascular grafting of abdominal aortic aneurysms. J Vasc Surg 32:684–688
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Iezzi, R., Cotroneo, A.R. Endovascular repair of abdominal aortic aneurysms: CTA evaluation of contraindications. Abdom Imaging 31, 722–731 (2006). https://doi.org/10.1007/s00261-005-0399-0
Published:
Issue Date: