Skip to main content

Advertisement

Log in

Ventilation/perfusion ratios and simultaneous dual-radionuclide single-photon emission tomography with krypton-81m and technetium-99m macroaggregated albumin

  • Original article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract.

To date, there has been neither a good method to clarify the three-dimensional distribution of pulmonary ventilation/perfusion (V.A/Q.) ratios, nor a convenient way to assess V.A/Q. inequality. The purpose of this study was to develop a functional image of pulmonary V.A/Q. ratios based on data acquired with simultaneous dual-radionuclide single-photon emission tomography (SPET) and to assess V.A/Q. unevenness through the V.A/Q. histogram in patients with various pulmonary diseases. Dual-radionuclide SPET was performed with technetium-99m macroaggregated albumin (MAA) and krypton-81m, with the patient in the supine position. After correction for linear cross-talk, the total acquisition counts of both radionuclides were equalized. The V.A/Q. ratio, which was calculated in each pixel by dividing the 81mKr count by the 99mTc-MAA count, was expressed as a V.A/Q. image. A histogram of the pixel number plotted against the V.A/Q. ratios was then produced and its centre of weight (CW) and standard deviation (SD) determined. Ten healthy volunteers and 46 patients [seven with pulmonary vascular disease (PVD), nine with pulmonary emphysema (PE), 18 with bronchogenic carcinoma and 12 with miscellaneous diseases] participated in this study. In normal volunteers, V.A/Q. ratios were generally even, but were slightly lower in dorsal regions. Patients with PVD had lobar and/or segmental areas with a high V.A/Q. ratio. Low V.A/Q. areas extended widely in patients with PE. Bronchogenic carcinoma exceeding 3 cm in diameter was detected as a very low V.A/Q. area. The SD of V.A/Q. ratios had a significant positive correlation both with A-aDO2 (r=0.64, P<0.001) and with cigarette smoking history (r=0.72, P<0.001). It is concluded that the V.A/Q. ratio image produced with simultaneous dual-radionuclide SPET using 99mTc-MAA and 81mKr is a unique and simple method for demonstrating the three-dimensional distribution of V.A/Q. ratios. The unevenness of V.A/Q. distribution can be assessed through the SD of the V.A/Q. histogram.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 22 February and in revised form 8 June 1997

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sando, Y., Inoue, T., Nagai, R. et al. Ventilation/perfusion ratios and simultaneous dual-radionuclide single-photon emission tomography with krypton-81m and technetium-99m macroaggregated albumin. Eur J Nucl Med 24, 1237–1244 (1997). https://doi.org/10.1007/s002590050147

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590050147

Navigation