Leakage assessment in adjustable laparoscopic gastric banding: radiography versus 99mTc-pertechnetate scintigraphy

  • Original Article
  • Published:
European Journal of Nuclear Medicine and Molecular Imaging Aims and scope Submit manuscript

Abstract.

The least invasive of all surgical weight-lowering procedures is the adjustable laparoscopic gastric banding (ALGB) technique. A rare complication (0.9%–1.8% of patients) but one that may require surgical revision is leakage of the gastric banding device. This paper reports on the usefulness of technetium-99m scintigraphy for the assessment of gastric band leaks as compared with radiography. Between March 1997 and October 2001, 23 obese patients (20 women and 3 men; mean age 35 years; range 23–60 years; mean body mass index before gastric banding procedure, 39.2 kg/m2; range 29.3–52.1 kg/m2) were referred for exclusion of gastric banding leakage by means of radiography and 99mTc-pertechnetate scintigraphy. Both procedures were performed on the same day in all patients. Two patients underwent both procedures, respectively two and three times. A total of 27 radiographic and scintigraphic examinations were performed. Radiographs were judged positive for leakage when escape of contrast agent through a defect in the gastric banding device was visualised or when indirect criteria, e.g. smooth passage of barium suspension through the stoma after injection of contrast agent, were present. Scintigraphic images were judged positive when tracer disappearance out of the banding device and uptake in the thyroid gland as well as enhancement of the gastric mucosa were observed 30 min and/or 3 h post injection. Overall sensitivity, specificity and accuracy for radiography and 99mTc scintigraphy were 81.8% vs 81.8%, 75% vs 100% and 77.7% vs 92.6%. Leakage from the reservoir or the connecting tube is a late complication of ALGB. The presented data suggest that 99mTc-pertechnetate scintigraphy is more efficient than radiography in determining the presence of such leaks.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 10 December 2001 and in revised form 3 March 2002

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Van Den Bossche, B., Goethals, I., Dierckx, R. et al. Leakage assessment in adjustable laparoscopic gastric banding: radiography versus 99mTc-pertechnetate scintigraphy. Eur J Nucl Med 29, 1128–1131 (2002). https://doi.org/10.1007/s00259-002-0825-2

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00259-002-0825-2

Navigation