Three-dimensional volumetric MRI with isotropic resolution: improved speed of acquisition, spatial resolution and assessment of lesion conspicuity in patients with recurrent soft tissue sarcoma

  • Scientific Article
  • Published:
Skeletal Radiology Aims and scope Submit manuscript

Abstract

Background

To assess the acquisition speed, lesion conspicuity, and inter-observer agreement associated with volumetric T1-weighted MR sequences with isotropic resolution for detecting recurrent soft-tissue sarcoma (STS).

Methods

Fifteen subjects with histologically proven recurrent STS underwent MRI, including axial and coronal T1-weighted spin echo (T1-WSE) (5-mm slice thickness) and coronal 3D volumetric T1-weighted (fat-suppressed, volume-interpolated, breath-hold examination; repetition time/echo time, 3.7/1.4 ms; flip angle, 9.5°; 1-mm slice thickness) sequences before and after intravenous contrast administration. Subtraction imaging and multiplanar reformations (MPRs) were performed. Acquisition times for T1-WSE in two planes and 3D sequences were reported. Two radiologists reviewed images for quality (>50 % artifacts, 25–50 % artifacts, <25 % artifacts, and no substantial artifacts), lesion conspicuity, contrast-to-noise ratio (CNRmuscle), recurrence size, and recurrence-to-joint distance. Descriptive and intraclass correlation (ICC) statistics are given.

Results

Mean acquisition times were significantly less for 3D imaging compared with 2-plane T1-WSE (183.6 vs 342.6 s; P = 0.012). Image quality was rated as having no substantial artifacts in 13/15 and <25 % artifacts in 2/15. Lesion conspicuity was significantly improved for subtracted versus unsubtracted images (CNRmuscle, 100 ± 138 vs 181 ± 199; P = 0.05). Mean recurrent lesion size was 2.5 cm (range, 0.7–5.7 cm), and measurements on 3D sequences offered excellent interobserver agreement (ICC, 0.98 for lesion size and 0.96 for recurrence-to-joint distance with MPR views).

Conclusion

Three-dimensional volumetric sequences offer faster acquisition times, higher spatial resolution, and MPR capability compared with 2D T1-WSE for postcontrast imaging. Subtraction imaging provides higher lesion conspicuity for detecting recurrent STS in skeletal muscle, with excellent interobserver agreement between readers.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

Explore related subjects

Discover the latest articles, news and stories from top researchers in related subjects.

References

  1. Azevedo RM, de Campos RO, Ramalho M, Heredia V, Dale BM, Semelka RC. Free-breathing 3D T1-weighted gradient-echo sequence with radial data sampling in abdominal MRI: preliminary observations. Am J Roentgenol. 2011;197(3):650–7.

    Article  Google Scholar 

  2. Bamrungchart S, Tantaway EM, Midia EC et al. Free breathing three-dimensional gradient echo-sequence with radial data sampling (radial 3D-GRE) examination of the pancreas: comparison with standard 3D-GRE volumetric interpolated breathhold examination (VIBE). J Mag Reson Imaging: JMRI. 2013;38(6):1572–7.

    Article  Google Scholar 

  3. Chandarana H, Block TK, Rosenkrantz AB et al. Free-breathing radial 3D fat-suppressed T1-weighted gradient echo sequence: a viable alternative for contrast-enhanced liver imaging in patients unable to suspend respiration. Investig Radiol. 2011;46(10):648–53.

    Article  Google Scholar 

  4. Fink C, Puderbach M, Biederer J et al. Lung MRI at 1.5 and 3 Tesla: observer preference study and lesion contrast using five different pulse sequences. Investig Radiol. 2007;42(6):377–83.

    Article  Google Scholar 

  5. Karabulut N, Martin DR, Yang M, Tallaksen RJ. MR imaging of the chest using a contrast-enhanced breath-hold modified three-dimensional gradient-echo technique: comparison with two-dimensional gradient-echo technique and multidetector CT. Am J Roentgenol. 2002;179(5):1225–33.

    Article  Google Scholar 

  6. Kataoka M, Ueda H, Koyama T et al. Contrast-enhanced volumetric interpolated breath-hold examination compared with spin-echo T1-weighted imaging of head and neck tumors. Am J Roentgenol. 2005;184(1):313–9.

    Article  Google Scholar 

  7. Kim KW, Lee JM, Jeon YS et al. Free-breathing dynamic contrast-enhanced MRI of the abdomen and chest using a radial gradient echo sequence with K-space weighted image contrast (KWIC). Eur Radiol. 2013;23(5):1352–60.

    Article  PubMed  Google Scholar 

  8. Lauenstein TC, Goehde SC, Herborn CU et al. Three-dimensional volumetric interpolated breath-hold MR imaging for whole-body tumor staging in less than 15 minutes: a feasibility study. Am J Roentgenol. 2002;179(2):445–9.

    Article  Google Scholar 

  9. Lee VS, Lavelle MT, Rofsky NM et al. Hepatic MR imaging with a dynamic contrast-enhanced isotropic volumetric interpolated breath-hold examination: feasibility, reproducibility, and technical quality. Radiology. 2000;215(2):365–72.

    Article  CAS  PubMed  Google Scholar 

  10. Michaely HJ, Morelli JN, Budjan J et al. CAIPIRINHA-Dixon-TWIST (CDT)-volume-interpolated breath-hold examination (VIBE): a new technique for fast time-resolved dynamic 3-dimensional imaging of the abdomen with high spatial resolution. Investig Radiol. 2013;48(8):590–7.

    Article  CAS  Google Scholar 

  11. Rofsky NM, Lee VS, Laub G et al. Abdominal MR imaging with a volumetric interpolated breath-hold examination. Radiology. 1999;212(3):876–84.

    Article  CAS  PubMed  Google Scholar 

  12. Vogt FM, Antoch G, Hunold P et al. Parallel acquisition techniques for accelerated volumetric interpolated breath-hold examination magnetic resonance imaging of the upper abdomen: assessment of image quality and lesion conspicuity. J Magn Reson Imaging. 2005;21(4):376–82.

    Article  PubMed  Google Scholar 

  13. Wu X, Raz E, Block TK et al. Contrast-enhanced radial 3D fat-suppressed T1-weighted gradient-recalled echo sequence versus conventional fat-suppressed contrast-enhanced T1-weighted studies of the head and neck. Am J Roentgenol. 2014;203(4):883–9.

    Article  Google Scholar 

  14. Yu MH, Lee JM, Yoon JH, Kiefer B, Han JK, Choi BI. Clinical application of controlled aliasing in parallel imaging results in a higher acceleration (CAIPIRINHA)-volumetric interpolated breathhold (VIBE) sequence for gadoxetic acid-enhanced liver MR imaging. J Magn Reson Imaging. 2013;38(5):1020–6.

    Article  PubMed  Google Scholar 

  15. Ogul H, Karaca L, Can CE et al. Anatomy, variants, and pathologies of the superior glenohumeral ligament: magnetic resonance imaging with three-dimensional volumetric interpolated breath-hold examination sequence and conventional magnetic resonance arthrography. Korean J Radiol. 2014;15(4):508–22.

    Article  PubMed  PubMed Central  Google Scholar 

  16. Tian CY, Shang Y, Zheng ZZ. Glenoid bone lesions: comparison between 3D VIBE images in MR arthrography and nonarthrographic MSCT. J Magn Reson Imaging. 2012;36(1):231–6.

    Article  PubMed  Google Scholar 

  17. Zheng ZZ, Shan H, Li X. Fat-suppressed 3D T1-weighted gradient-echo imaging of the cartilage with a volumetric interpolated breath-hold examination. Am J Roentgenol. 2010;194(5):W414–419.

    Article  Google Scholar 

  18. Del Grande F, Subhawong T, Weber K, Aro M, Mugera C, Fayad LM. Detection of soft-tissue sarcoma recurrence: added value of functional MR imaging techniques at 3.0 T. Radiology. 2014;271(2):499–511.

    Article  PubMed  Google Scholar 

  19. Fayad LM, Blakeley J, Plotkin S, Widemann B, Jacobs MA. Whole body MRI at 3T with quantitative diffusion weighted imaging and contrast-enhanced sequences for the characterization of peripheral lesions in patients with neurofibromatosis type 2 and schwannomatosis. ISRN Radiol. 2013;2013:627932.

    Article  PubMed  PubMed Central  Google Scholar 

  20. Fayad LM, Jacobs MA, Wang X, Carrino JA, Bluemke DA. Musculoskeletal tumors: how to use anatomic, functional, and metabolic MR techniques. Radiology. 2012;265(2):340–56.

    Article  PubMed  PubMed Central  Google Scholar 

  21. Zilkens C, Miese F, Herten M et al. Validity of gradient-echo three-dimensional delayed gadolinium-enhanced magnetic resonance imaging of hip joint cartilage: a histologically controlled study. Eur J Radiol. 2013;82(2):e81–86.

    Article  PubMed  Google Scholar 

  22. Thomson V, Pialat JB, Gay F et al. Whole-body MRI for metastases screening: a preliminary study using 3D VIBE sequences with automatic subtraction between noncontrast and contrast enhanced images. Am J Clin Oncol. 2008;31(3):285–92.

    Article  PubMed  Google Scholar 

  23. Yu JS, Kim YH, Rofsky NM. Dynamic subtraction magnetic resonance imaging of cirrhotic liver: assessment of high signal intensity lesions on nonenhanced T1-weighted images. J Comput Assist Tomogr. 2005;29(1):51–8.

    Article  PubMed  Google Scholar 

  24. Yu JS, Rofsky NM. Dynamic subtraction MR imaging of the liver: advantages and pitfalls. Am J Roentgenol. 2003;180(5):1351–7.

    Article  Google Scholar 

  25. Andrews CL, Golla SK, Smith DA, Wilmot AS, Leeman KA, Aldred PW. Best practices: are pre-contrast T1 fat suppression sequences necessary in Musculoskeletal Radiology Clinical Imaging. Paper presented at: Society of Skeletal Radiology Meeting; March 8–11, 2015; Scottsdale, AZ.

  26. Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biogeosciences. 1977;33:159–74.

    CAS  Google Scholar 

  27. Johnson G, Wadghiri YZ, Turnbull DH. 2D multislice and 3D MRI sequences are often equally sensitive. Magn Reson Med. 1999;41(4):824–8.

    Article  CAS  PubMed  Google Scholar 

  28. Wetzel SG, Johnson G, Tan AG et al. Three-dimensional, T1-weighted gradient-echo imaging of the brain with a volumetric interpolated examination. Am J Neuroradiol. 2002;23(6):995–1002.

    PubMed  Google Scholar 

  29. Barile A, Caulo M, Zugaro L, Di Cesare E, Gallucci M, Masciocchi C. Staging and re-staging of soft tissue sarcoma using MRI: usefulness of contrast media. Radiol Med. 2001;101(6):444–55.

    CAS  PubMed  Google Scholar 

  30. Garner HW, Kransdorf MJ. Musculoskeletal sarcoma: update on imaging of the post-treatment patient. Can Assoc Radiol J. 2016;67(1):12–20.

  31. Garner HW, Kransdorf MJ, Bancroft LW, Peterson JJ, Berquist TH, Murphey MD. Benign and malignant soft-tissue tumors: posttreatment MR imaging. Radiographics. 2009;29(1):119–34.

    Article  PubMed  Google Scholar 

  32. Vanel D, Shapeero LG, Tardivon A, Western A, Guinebretiere JM. Dynamic contrast-enhanced MRI with subtraction of aggressive soft tissue tumors after resection. Skelet Radiol. 1998;27(9):505–10.

    Article  CAS  Google Scholar 

  33. Diana Afonso P, Kosinski AS, Spritzer CE. Following unenhanced MRI assessment for local recurrence after surgical resection of mesenchymal soft tissue tumors, do additional gadolinium-enhanced images change reader confidence or diagnosis? Eur J Radiol. 2013;82(5):806–13.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Shivani Ahlawat.

Ethics declarations

Disclosure of potential conflicts of interest

Authors declare that they have no conflict of interest.

Research involving human participants and/or animals

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.

Informed consent

Informed consent was waived from all individual participants included in the study because it was a retrospective study of MR imaging performed for clinical purposes.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ahlawat, S., Morris, C. & Fayad, L.M. Three-dimensional volumetric MRI with isotropic resolution: improved speed of acquisition, spatial resolution and assessment of lesion conspicuity in patients with recurrent soft tissue sarcoma. Skeletal Radiol 45, 645–652 (2016). https://doi.org/10.1007/s00256-016-2348-0

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00256-016-2348-0

Keywords

Navigation