Abstract

Background

Disadvantages of fluoroscopically guided lumbar puncture include delivery of ionizing radiation and limited resolution of incompletely ossified posterior elements. Ultrasound (US) allows visualization of critical soft tissues and the cerebrospinal fluid (CSF) space without ionizing radiation.

Objective

To determine the technical success and safety of US-guided lumbar puncture in pediatric patients.

Materials and methods

A retrospective review identified all patients referred to interventional radiology for lumbar puncture between June 2010 and June 2017. Patients who underwent lumbar puncture with fluoroscopic guidance alone were excluded. For the remaining procedures, technical success and procedural complications were assessed. Two hundred and one image-guided lumbar punctures in 161 patients were included. Eighty patients (43%) had previously failed landmark-based attempts.

Results

One hundred ninety-six (97.5%) patients underwent lumbar puncture. Five procedures (2.5%) were not attempted after US assessment, either due to a paucity of CSF or unsafe window for needle placement. Technical success was achieved in 187 (95.4%) of lumbar punctures attempted with US guidance. One hundred seventy-seven (90.3%) were technically successful with US alone (age range: 2 days-15 years, weight range: 1.9-53.1 kg) and an additional 10 (5.1%) were successful with US-guided thecal access and subsequent fluoroscopic confirmation. Three (1.5%) cases were unsuccessful with US guidance but were subsequently successful with fluoroscopic guidance. Of the 80 previously failed landmark-based lumbar punctures, 77 (96.3%) were successful with US guidance alone. There were no reported complications.

Conclusion

US guidance is safe and effective for lumbar punctures and has specific advantages over fluoroscopy in pediatric patients.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Avery RA (2014) Reference range of cerebrospinal fluid opening pressure in children: historical overview and current data. Neuropediatrics 45:206–211

    Article  PubMed  PubMed Central  Google Scholar 

  2. Bonadio W (2014) Pediatric lumbar puncture and cerebrospinal fluid analysis. J Emerg Med 46:141–150

    Article  PubMed  Google Scholar 

  3. Pui CH, Howard SC (2008) Current management and challenges of malignant disease in the CNS in paediatric leukaemia. Lancet Oncol 9:257–268

    Article  PubMed  Google Scholar 

  4. Cauley KA (2015) Fluoroscopically guided lumbar puncture. AJR Am J Roentgenol 205:W442–W450

    Article  PubMed  Google Scholar 

  5. Eskey CJ, Ogilvy CS (2001) Fluoroscopy-guided lumbar puncture: decreased frequency of traumatic tap and implications for the assessment of CT-negative acute subarachnoid hemorrhage. AJNR Am J Neuroradiol 22:571–576

    PubMed  CAS  Google Scholar 

  6. Brenner DJ, Hall EJ (2007) Computed tomography — an increasing source of radiation exposure. N Engl J Med 357:2277–2284

    Article  PubMed  CAS  Google Scholar 

  7. Coley BD, Shiels WE, Hogan MJ (2001) Diagnostic and interventional ultrasonography in neonatal and infant lumbar puncture. Pediatr Radiol 31:399–402

    Article  PubMed  CAS  Google Scholar 

  8. Wang PI, Wang AC, Naidu JO et al (2013) Sonographically guided lumbar puncture in pediatric patients. J Ultrasound Med 32:2191–2197

    Article  PubMed  Google Scholar 

  9. Mazor SS, McNulty JE, Roosevelt GE (2003) Interpretation of traumatic lumbar punctures: who can go home? Pediatrics 111:525–528

    PubMed  Google Scholar 

  10. Kim S, Adler DK (2014) Ultrasound-assisted lumbar puncture in pediatric emergency medicine. J Emerg Med 47:59–64

    Article  PubMed  Google Scholar 

  11. Muthusami P, Robinson AJ, Shroff MM (2017) Ultrasound guidance for difficult lumbar puncture in children: pearls and pitfalls. Pediatr Radiol 47:822–830

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Eric J. Monroe.

Ethics declarations

Conflicts of interest

None

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Pierce, D.B., Shivaram, G., Koo, K.S.H. et al. Ultrasound-guided lumbar puncture in pediatric patients: technical success and safety. Pediatr Radiol 48, 875–881 (2018). https://doi.org/10.1007/s00247-018-4091-2

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00247-018-4091-2

Keywords

Navigation