Skip to main content

Advertisement

Log in

Pediatric CT quality management and improvement program

  • Image Gently ALARA CT summit: How to Use New CT Technologies for Children
  • Published:
Pediatric Radiology Aims and scope Submit manuscript

Abstract

Modern CT is a powerful yet increasingly complex technology that continues to rapidly evolve; optimal clinical implementation as well as appropriate quality management and improvement in CT are challenging but attainable. This article outlines the organizational structure on which a CT quality management and improvement program can be built, followed by a discussion of common as well as pediatric-specific challenges. Organizational elements of a CT quality management and improvement program include the formulation of clear objectives; definition of the roles and responsibilities of key personnel; implementation of a technologist training, coaching and feedback program; and use of an efficient and accurate monitoring system. Key personnel and roles include a radiologist as the CT director, a qualified CT medical physicist, as well as technologists with specific responsibilities and adequate time dedicated to operation management, CT protocol management and CT technologist education. Common challenges in managing a clinical CT operation are related to the complexity of newly introduced technology, of training and communication and of performance monitoring. Challenges specific to pediatric patients include the importance of including patient size in protocol and dose considerations, a lower tolerance for error in these patients, and a smaller sample size from which to learn and improve.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Flohr TG, Schaller S, Stierstorfer K et al (2005) Multi-detector row CT systems and image-reconstruction techniques. Radiology 235:756–773

    Article  PubMed  Google Scholar 

  2. Berrington de González A, Mahesh M, Kim K-P et al (2009) Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 169:2071–2077

    Article  PubMed  Google Scholar 

  3. Frush DP, Morin R, Rehani MM (2013) Monitoring of medical radiation exposure for individuals. In: Lau L, Kwan-Hoong N (eds) Radiology safety and quality. Springer, New York, pp 69–84

    Google Scholar 

  4. Kalra MK, Maher MM, Toth TL et al (2004) Strategies for CT radiation dose optimization. Radiology 230:619–628

    Article  PubMed  Google Scholar 

  5. Cody DD, Fisher TS, Gress DA et al (2013) AAPM medical physics practice guideline 1.a: CT protocol management and review practice guideline. J Appl Clin Med Phys 14:3–12

    PubMed  Google Scholar 

  6. Larson DB, Johnson LW, Schnell BM et al (2011) Rising use of CT in child visits to the emergency department in the United States, 1995–2008. Radiology 259:793–801

    Article  PubMed  Google Scholar 

  7. (1991) Standards for protection against radiation — Nuclear Regulatory Commission. Final rule. Fed Regist 56:23360–23474

  8. National Council on Radiation Protection and Measurements (2012) Reference levels and achievable doses in medical and dental imaging: recommendations for the United States. NCRPM report 172. National Council on Radiation Protection and Measurements, Bethesda, MD

  9. Larson DB, Wang LL, Podberesky DJ et al (2013) System for verifiable CT radiation dose optimization based on image quality. Part I: optimization model. Radiology 269:167–176

  10. Larson DB, Malarik RJ, Hall SM et al (2013) System for verifiable CT radiation dose optimization based on image quality. Part II: process control system. Radiology 269:177–185

  11. Fleischmann D (2009) Contrast medium administration in computed tomographic angiography. In: Rubin GD, Rofsky NM (eds) CT and MR angiography. Lippincott Williams & Wilkins, Philadelphia, pp 129–154

    Google Scholar 

  12. Fleischmann D, Kamaya A (2009) Optimal vascular and parenchymal contrast enhancement: the current state of the art. Radiol Clin North Am 47:13–26

    Article  PubMed  Google Scholar 

  13. Goldman LW (2007) Principles of CT: radiation dose and image quality. J Nucl Med Technol 35:213–225

    Article  PubMed  Google Scholar 

  14. Renne J, Falck CV, Ringe KI et al. (2013) CT angiography for pulmonary embolism detection: the effect of breathing on pulmonary artery enhancement using a 64-row detector system. Acta Radiol [Epub ahead of print]

  15. Talati RK, Dunkin J, Parikh S et al (2013) Current methods of monitoring radiation exposure from CT. J Am Coll Radiol 10:702–707

    Article  PubMed  Google Scholar 

  16. Wang J, Duan X, Christner JA et al (2012) Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part I. Development and validation of methods using the CT image. Med Phys 39:6764–6771

    Article  PubMed  Google Scholar 

  17. Wang J, Christner JA, Duan X et al (2012) Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part II. Implementation on abdomen and thorax phantoms using cross sectional CT images and scanned projection radiograph images. Med Phys 39:6772–6778

    Article  PubMed  Google Scholar 

  18. Kleinman PL, Strauss KJ, Zurakowski D et al (2010) Patient size measured on CT images as a function of age at a tertiary care children’s hospital. AJR Am J Roentgenol 194:1611–1619

    Article  PubMed  Google Scholar 

  19. Li X, Samei E, Williams CH et al (2012) Effects of protocol and obesity on dose conversion factors in adult body CT. Med Phys 39:6550–6571

    Article  PubMed  PubMed Central  Google Scholar 

  20. Menke J (2005) Comparison of different body size parameters for individual dose adaptation in body CT of adults. Radiology 236:565–571

    Article  PubMed  Google Scholar 

Download references

Conflicts of interest

Dr. Larson discloses a commercial interest in Radimetrics and has no investigational or off-label uses to disclose. Drs. Molvin, Wang, Chan, Newman and Fleischmann have no financial interests, investigational or off-label uses to disclose.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to David B. Larson.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Larson, D.B., Molvin, L.Z., Wang, J. et al. Pediatric CT quality management and improvement program. Pediatr Radiol 44 (Suppl 3), 519–524 (2014). https://doi.org/10.1007/s00247-014-3039-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00247-014-3039-4

Keywords

Navigation