Skip to main content

Advertisement

Log in

Right Ventricular Volumes, Ejection Fraction, and Systolic Function Indices in Normal Neonates by Three-Dimensional Speckle-Tracking Echocardiography

  • Original Article
  • Published:
Pediatric Cardiology Aims and scope Submit manuscript

Abstract

The aim of this study was to test the feasibility of measuring right ventricular (RV) volumes, ejection fraction (EF), and systolic function indices in neonates using three-dimensional speckle-tracking echocardiography (3D-STE). Thirty-eight neonates underwent complete echocardiographic evaluation, including the acquisition of three full-volume 3D datasets or more from each of the apical, parasternal, and subcostal windows while naturally sleeping. Datasets were analyzed using a commercially available software (Tomtec). Global RV 3D volumes and EF were measured. In addition, 2D free wall longitudinal strain (LS), tricuspid valve annulus (TVA), tricuspid annular plane systolic excursion (TAPSE) and its index to RV length (TAPSEi), and fractional area change (FAC) were obtained from a non-shortened apical 4-chamber view of the RV, derived from the 3D dataset. Three or more datasets obtained from the apical window were available for analysis for each subject. At least one dataset was adequate for analysis in all subjects. Mean indexed 3D diastolic, systolic, stroke volumes, and EF were measured at 28.5 ± 3.4 ml/m2, 13 ± 2.0 ml/m2, 15.6 ± 1.9 ml/m2, and 54.6 ± 3.2%, respectively. Free wall 2D LS was calculated at (− 27.9 ± 2.5%). In addition, mean TVA measured 11.1 ± 0.8 mm, TAPSE measured 6.8 ± 0.9 mm, and TAPSEi and FAC were calculated at 24.2 ± 2.1 and 46 ± 3.4%, respectively. 3D-STE is feasible in normal neonates without the need for sedation. Reference values of RV 3D volumes and 2D indices of systolic function were obtained. These data could be helpful in patients where the size or systolic function of the RV is in question. Larger studies are required to establish nomograms for the above indices in this age group.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

Data Availability

Available upon request.

References

  1. Smith A, Purna JR, Castaldo MP et al (2019) Accuracy and reliability of qualitative echocardiographic assessment of right ventricular size and function in neonates. Echocardiography 36:2285–2285. https://doi.org/10.1111/echo.14409

    Article  Google Scholar 

  2. Ho SY, Nihoyannopoulos P (2006) Anatomy, echocardiography, and normal right ventricular dimensions. Heart 92(Suppl_1):I2–I13. https://doi.org/10.1136/hrt.2005.077875

    Article  PubMed  PubMed Central  Google Scholar 

  3. Foale R, Nihoyannopoulos P, Mckenna W et al (1986) Echocardiographic measurement of the normal adult right ventricle. Heart 56(1):33–44. https://doi.org/10.1136/hrt.56.1.33

    Article  CAS  Google Scholar 

  4. Lai WW, Geva T, Shirali GS et al (2006) Guidelines and standards for performance of a pediatric echocardiogram: a Report from the Task Force of the Pediatric Council of the American Society of Echocardiography. J Am Soc Echocardiogr 19(12):1413–1430. https://doi.org/10.1016/j.echo.2006.09.001

    Article  PubMed  Google Scholar 

  5. Sugeng L, Mor-Avi V, Weinert L et al (2006) Quantitative assessment of left ventricular size and function. Circulation 114(7):654–661. https://doi.org/10.1161/circulationaha.106.626143

    Article  PubMed  Google Scholar 

  6. Jacobs LD, Salgo IS, Goonewardena S et al (2005) Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data. Eur Heart J 27(4):460–468. https://doi.org/10.1093/eurheartj/ehi666

    Article  PubMed  Google Scholar 

  7. Friedberg MK, Su X, Tworetzky W et al (2010) Validation of 3D echocardiographic assessment of left ventricular volumes, mass, and ejection fraction in neonates and infants with congenital heart disease. Circ Cardiovasc Imaging 3(6):735–742. https://doi.org/10.1161/circimaging.109.928663

    Article  PubMed  Google Scholar 

  8. Kaku K, Takeuchi M, Tsang W et al (2014) Age-related normal range of left ventricular strain and torsion using three-dimensional speckle-tracking echocardiography. J Am Soc Echocardiogr 27(1):55–64. https://doi.org/10.1016/j.echo.2013.10.002

    Article  PubMed  Google Scholar 

  9. Bulbul Z, Issa Z, Siblini G et al (2015) Normal range of left ventricular strain, dimensions and ejection fraction using three-dimensional speckle-tracking echocardiography in neonates. J Cardiovasc Echogr 25(3):67. https://doi.org/10.4103/2211-4122.166074

    Article  PubMed  PubMed Central  Google Scholar 

  10. Shimada YJ, Shiota M, Siegel RJ, Shiota T (2010) Accuracy of right ventricular volumes and function determined by three-dimensional echocardiography in comparison with magnetic resonance imaging: a meta-analysis study. J Am Soc Echocardiogr Off Publ Am Soc Echocardiogr 23(9):943–953. https://doi.org/10.1016/j.echo.2010.06.029

    Article  Google Scholar 

  11. Grewal J, Majdalany D, Syed I et al (2010) Three-dimensional echocardiographic assessment of right ventricular volume and function in adult patients with congenital heart disease: comparison with magnetic resonance imaging. J Am Soc Echocardiogr 23(2):127–133. https://doi.org/10.1016/j.echo.2009.11.002

    Article  PubMed  Google Scholar 

  12. Selly JB, Iriart X, Roubertie F et al (2015) Multivariable assessment of the right ventricle by echocardiography in patients with repaired Tetralogy of Fallot undergoing pulmonary valve replacement: a comparative study with magnetic resonance imaging. Arch Cardiovasc Dis 108(1):5–15. https://doi.org/10.1016/j.acvd.2014.07.054

    Article  PubMed  Google Scholar 

  13. Atsumi A, Seo Y, Ishizu T et al (2016) Right ventricular deformation analyses using a three-dimensional speckle-tracking echocardiographic system specialized for the right ventricle. J Am Soc Echocardiogr Off Publ Am Soc Echocardiogr 29(5):402-411.e2. https://doi.org/10.1016/j.echo.2015.12.014

    Article  Google Scholar 

  14. Muraru D, Spadotto V, Cecchetto A et al (2015) New speckle-tracking algorithm for right ventricular volume analysis from three-dimensional echocardiographic data sets: validation with cardiac magnetic resonance and comparison with the previous analysis tool. Eur Heart J Cardiovasc Imaging 17(11):1279–1289. https://doi.org/10.1093/ehjci/jev309

    Article  PubMed  Google Scholar 

  15. Malowitz JR, Forsha DE, Smith PB et al (2015) Right ventricular echocardiographic indices predict poor outcomes in infants with persistent pulmonary hypertension of the newborn. Eur Heart J Cardiovasc Imaging 16(11):1224–1231. https://doi.org/10.1093/ehjci/jev071

    Article  PubMed  PubMed Central  Google Scholar 

  16. Chikkabyrappa SM, Critser P, Roane J et al (2020) Tripartite assessment of right ventricular systolic function in persistent pulmonary hypertension of the newborn. Pediatr Cardiol 41(6):1206–1211. https://doi.org/10.1007/s00246-020-02376-1

    Article  PubMed  Google Scholar 

  17. Balasubramanian S, Smith SN, Srinivasan P et al (2021) Longitudinal assessment of right ventricular function in hypoplastic left heart syndrome. Pediatr Cardiol. https://doi.org/10.1007/s00246-021-02624-y.Advanceonlinepublication

    Article  PubMed  Google Scholar 

  18. Kjaergaard J, Petersen CL, Kjaer A et al (2006) Evaluation of right ventricular volume and function by 2D and 3D echocardiography compared to MRI. Eur J Echocardiogr J Work Group Echocardiogr Eur Soc Cardiol 7(6):430–438. https://doi.org/10.1016/j.euje.2005.10.009

    Article  Google Scholar 

  19. Schindera ST, Mehwald PS, Sahn DJ et al (2002) Accuracy of real-time three-dimensional echocardiography for quantifying right ventricular volume: static and pulsatile flow studies in an anatomic in vitro model. J Ultrasound Med Off J Am Inst Ultrasound Med 21(10):1069–1075. https://doi.org/10.7863/jum.2002.21.10.1069

    Article  Google Scholar 

  20. Leibundgut G, Rohner A, Grize L et al (2010) Dynamic assessment of right ventricular volumes and function by real-time three-dimensional echocardiography: a comparison study with magnetic resonance imaging in 100 adult patients. J Am Soc Echocardiogr Off Publ Am Soc Echocardiogr 23(2):116–126. https://doi.org/10.1016/j.echo.2009.11.016

    Article  Google Scholar 

  21. Kutty S, Graney BA, Khoo NS et al (2012) Serial assessment of right ventricular volume and function in surgically palliated hypoplastic left heart syndrome using real-time transthoracic three-dimensional echocardiography. J Am Soc Echocardiogr Off Publ Am Soc Echocardiogr 25(6):682–689. https://doi.org/10.1016/j.echo.2012.02.008

    Article  Google Scholar 

  22. Tamborini G, Marsan NA, Gripari P et al (2010) Reference values for right ventricular volumes and ejection fraction with real-time three-dimensional echocardiography: evaluation in a large series of normal subjects. J Am Soc Echocardiogr Off Publ Am Soc Echocardiogr 23(2):109–115. https://doi.org/10.1016/j.echo.2009.11.026

    Article  Google Scholar 

  23. Mertens L, Seri I, Marek J, et al, Writing Group of the American Society of Echocardiography, European Association ofEchocardiography, Association for European Pediatric Cardiologists (2011) Targeted Neonatal Echocardiography in the Neonatal Intensive Care Unit: practice guidelines and recommendations for training. Writing Group of the American Society of Echocardiography (ASE) in collaboration with the European Association of Echocardiography (EAE) and the Association for European Pediatric Cardiologists (AEPC). J Am Soc Echocardiogr Off Publ Am Soc Echocardiogr 24(10):1057–1078. https://doi.org/10.1016/j.echo.2011.07.014

  24. Levy PT, Holland MR, Sekarski TJ et al (2013) Feasibility and reproducibility of systolic right ventricular strain measurement by speckle-tracking echocardiography in premature infants. J Am Soc Echocardiogr Off Publ Am Soc Echocardiogr 26(10):1201–1213. https://doi.org/10.1016/j.echo.2013.06.005

    Article  Google Scholar 

  25. Levy PT, Dioneda B, Holland MR et al (2015) Right ventricular function in preterm and term neonates: reference values for right ventricle areas and fractional area of change. J Am Soc Echocardiogr Off Publ Am Soc Echocardiogr 28(5):559–569. https://doi.org/10.1016/j.echo.2015.01.024

    Article  Google Scholar 

  26. Ghandi Y, Habibi D, Farahani E (2018) Reference values of longitudinal systolic right and left ventricular function measured by M-mode echocardiography in healthy preterm and term neonates. J Cardiovasc Echogr 28(3):177–181. https://doi.org/10.4103/jcecho.jcecho_31_18

    Article  PubMed  PubMed Central  Google Scholar 

  27. Jain A, Mohamed A, El-Khuffash A et al (2014) A comprehensive echocardiographic protocol for assessing neonatal right ventricular dimensions and function in the transitional period: normative data and z scores. J Am Soc Echocardiogr Off Publ Am Soc Echocardiogr 27(12):1293–1304. https://doi.org/10.1016/j.echo.2014.08.018

    Article  Google Scholar 

Download references

Funding

This research received no specific grant from any funding agency, commercial, or not-for-profit sectors.

Author information

Authors and Affiliations

Authors

Contributions

ZRB is the principal investigator of the study and he put down the concept, designed the study, analyzed the datasets, wrote the initial draft, and finalized the article. GS helped design the study and in the analysis of the datasets. HT is the leading statistician on the paper and was responsible of data cleaning and analysis. MM assisted in the statistical analysis and interpretation of the data as well as formulation of the study tables. FB had reviewed and critically revised the initial and final drafts of the manuscript.

Corresponding author

Correspondence to Ziad Bulbul.

Ethics declarations

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be interpreted as a potential conflict of interest.

Ethical Approval

The study was performed in accordance with the ethical standards of the Research Ethics Committee and was approved by the Research Advisory Council/Office of Research Affairs at King Faisal Specialist Hospital and Research Center.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Bulbul, Z., Siblini, G., Tamim, H. et al. Right Ventricular Volumes, Ejection Fraction, and Systolic Function Indices in Normal Neonates by Three-Dimensional Speckle-Tracking Echocardiography. Pediatr Cardiol 43, 181–190 (2022). https://doi.org/10.1007/s00246-021-02716-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00246-021-02716-9

Keywords

Navigation